Welcome Customer !

Membership

Help

Fulde (Shanghai) Instrument Equipment Co., Ltd
Custom manufacturer

Main Products:

mechb2b>Products

Fulde (Shanghai) Instrument Equipment Co., Ltd

  • E-mail

    zr.zhang@verder.cn

  • Phone

  • Address

    Building 8, Fuhai Business Park (Phase I), Lane 299, Bisheng Road, Zhangjiang High tech Park, Shanghai

Contact Now

Laichi Technology CAMSIZER M1 Static Image Method Granularity Analyzer

NegotiableUpdate on 02/04
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Laichi Technology CAMSIZER M1 static image method particle size analyzer is a particle size and shape analyzer that uses static image method to comprehensively and accurately characterize sample particles. Laichi Technology CAMSIZER M1 is the * choice among static image particle size analyzers, providing excellent application effects for product development and quality control.

Product Details

Laichi Technology CAMSIZER M1 Static Image Method Granularity AnalyzerIt is a particle size and shape analyzer that uses static image method to comprehensively and accurately characterize sample particles. CAMSIZER M1 is selected as a static image method particle size analyzer, providing excellent application effects for product development and quality control.

Laichi Technology CAMSIZER M1 Static Image Method Granularity AnalyzerEquipped with powerful lighting equipment, high-precision sample stage, and 5 objective lenses with magnification ranging from 2.5x to 50x. The spacious sample stage can be used to evaluate the areas corresponding to 8 standard slides. The CAMSIZER M1 uses an 18.1-megapixel color camera for image acquisition, ensuring fast and accurate analysis of particles throughout the entire measurement range.

Application example of Laichi Technology CAMSIZER M1 static image method particle size analyzer

Active pharmaceutical ingredients and excipients, cement, ceramic powders, chemicals, fine grinding and polishing agents, fibers, food, industrial diamonds, metal powders, minerals ..

Laichi Technology CAMSIZER M1 Static Image Method Granularity Analyzeradvantage

  • hardware

  • Measurement range 0.5-1500 µ m

  • 18.1 million pixel color camera

  • Measurement can be done using either transmitted light or incident light, or both simultaneously

  • Multiple sample board trays to choose from, providing great flexibility

  • Equipped with 5 objective lenses, optional 1 objective lens

  • High precision controllable sample stage

  • Handheld control

  • Effective dispersion of sample powder using M-Jet module

  • software

  • Intuitive evaluation software

  • Simultaneously conducting particle size and shape analysis

  • The granularity definition includes width, equivalent ball diameter width, Feret diameter, Martin diameter, etc

  • Particle shape parameters include roundness, concavity, aspect ratio, compactness, etc

  • Particle X-Plorer software evaluates each particle after measurement

  • Establish a comprehensive particle database

  • Multiple evaluations and screening selections

  • The results display the corresponding quantity, area, and volume

  • Seamless stitching algorithm

  • Focus overlay

  • Conventional advantages

  • Quick and easy calibration

  • Various accessories

  • high-definition image

  • Simultaneously record particle data and images

  • automatic measurement

Performance indicators of Laichi Technology CAMSIZER M1 static image method particle size analyzer

Measuring principle Static image analysis (ISO 13322-1)
measurement range 0.5 µm - 1500 µm
analysis type Dry and wet analysis
measure time ~5-60 minutes (depending on sample type and measurement data)
resolution 18.1 megapixel color camera
Large digital resolution 35 nm
Available objective lens Standard: 2.5x 5x 10x 20x 50x Optional: 1.25x or 100x
weight(Measurement Unit) ~ 45 kg
Operation unit PC, Including Windows 10 operating system, 2 monitors, keyboard, mouse, and evaluation software

Laichi Technology CAMSIZER M1 Static Image Method Granularity AnalyzerPrinciple of action

CAMSIZER M1 uses static image method to measure the particle size and shape of particles, with a measurement range of 0.5 µ m-1500 µ m. The slider component loaded with sample material moves synchronously with the camera system, ensuring that one photo is taken with each step of movement. Both dry and wet samples (powders, suspensions) can be analyzed. compareDynamic image methodThe sample of static image method is fixed during the measurement process, so it can obtain higher quality particle images and capture richer details.


For each detection, the particle size analyzer CAMSIZER M1 automatically focuses on the observation plate to ensure that all particles in the selected area can obtain high-precision images (tilt compensation). During the analysis process, all images and measurement data can be stored, and the use of Particle X-Plorer software provides multiple possibilities for subsequent data evaluation. After the measurement is completed, the overall image provides customers with a clear understanding of particle quality. Through innovative stitching algorithms, seamless stitching of multiple measurement areas can be achieved, and even particles larger than 1500 μ m in size can be evaluated.

Based on technological transformation and error adjustment