Welcome Customer !

Membership

Help

Saizhi Technology (Hangzhou) Co., Ltd
Custom manufacturer

Main Products:

mechb2b>Products

Saizhi Technology (Hangzhou) Co., Ltd

  • E-mail

  • Phone

  • Address

    5th Floor, Building 3, Jinsheng Science and Technology Park, No. 611 Dongguan Road, Binjiang District, Hangzhou City, Zhejiang Province

Contact Now

LC8000 Dual High Voltage Automatic System (UV/AD)

NegotiableUpdate on 03/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The LC8000 binary high-pressure automatic system has excellent gradient accuracy and optimized delay volume, making it suitable for more complex application environments or in combination with mass spectrometry. With the convenience of automated sampling and multiple detectors brought by the sampler, obtaining more data is as easy as pie. It has ultra-high cost-effectiveness and good stability, and is easy to maintain. Meet routine analysis requirements, such as QA/QC methods and GPC/SEC applications. It can be easily upgraded to a multi automatic system when you need it.
Product Details


One LC8100 series solvent organizer

One LC8200 series high-pressure infusion pump

One LC8320 automatic sampler

1 LC8400 column temperature box

One LC8500 UV visible detector (or DAD detector)


The complete set of instruments, including workstations, complies with GMP/GLP and FDA CFR 21 PART 11 regulatory requirements!




(The specific indicators and parameters of this product are subject to the quotation)


1、 Organizer:

1. Piston online cleaning: standard, high/medium/low speed


2、 Infusion pump unit: binary high-pressure infusion pump

★ 1. Maximum pressure resistance: 9000 psi (62Mpa)

2. Flow rate range: 0.001 to 10.000 mL/min (increments of 0.001 mL/min)

★ 3. Traffic accuracy: ≤ 0.06% RSD(ASTM)

4. Flow accuracy: ± 0.2%

5. Pressure pulsation: ≤ 1%

6. Gradient accuracy: ± 0.5%

7. Gradient repeatability: ≤ 0.1%

★ 8. plunger online cleaning: standard, high/medium/low speed


3、 Detector: UV Visible Detector

1. Wavelength range: 190-800 nm

2. Light source: deuterium lamp, tungsten lamp

3. Spectral bandwidth: 8 nm

4. Wavelength accuracy: ±1 nm

★ 5. Noise: ±0.35×10-5 AU(ASTM)

★ 6. Drift: 1×10-4 AU/Hr

7. Wavelength accuracy: 0.2 nm

★ 8. Linear range:> 2.5AU (ASTM)

★ 9. Maximum sampling rate: 100Hz

10. Flow pool pressure resistance: 1200PSI

11. Flow pool optical path length: 10mm

12. Minimum detection concentration: 4×10-9 g/mL


4、 Injector: Automatic Injector

1. Injection mode: full loop injection/partial injection/microliter carrier injection

2. Quantitative ring volume: standard 100 μ L

3. Sample repeatability: Full cycle injection: RSD ≤ 0.3% Partial injection: RSD ≤ 0.5% microliter Carrying injection: RSD≤1%

4. Sample capacity: 2 standard 48 position sample bottle racks with 1.5mL injection bottles (standard)

(Optional 96 well plate, 384 well plate)

★ 5. Cross contamination: < 0.005%

6. Linear: 0.9999

7. Maximum pressure resistance: 6000psi (customizable)


5、 Column temperature box

1. Temperature control range: room temperature+5 ℃ -70 ℃

2. Temperature accuracy: ± 1.0 ℃

3. Temperature stability: ± 0.1 ℃

4. Column capacity: 1 250mm chromatographic column (can be equipped with an additional 10mm protective column)


6、 Chromatographic column

Standard C18250 × 4.6mm, 5um


7、 Chromatography workstation

1. Regulatory Applicability: Compliant with FDA 21 CFR Part 11/GMP/GLP specifications;

2. Usability: A graphical monitoring interface that allows for real-time monitoring of device status, making it simple and easy to use;

3. Data processing: powerful data processing capabilities, providing multiple integration functions and calculation methods;

4. Rich features: automatic peak width, automatic threshold algorithm, adaptive data collection, automatic adjustment algorithm to achieve the best integration effect;

5. User Management: With powerful and comprehensive user management functions, access permissions can be set for easy management, and different usage permissions can be set according to the actual needs of scientific research and teaching;