- Phone
-
Address
5th Floor, Building 3, Jinsheng Science and Technology Park, No. 611 Dongguan Road, Binjiang District, Hangzhou City, Zhejiang Province
Saizhi Technology (Hangzhou) Co., Ltd
5th Floor, Building 3, Jinsheng Science and Technology Park, No. 611 Dongguan Road, Binjiang District, Hangzhou City, Zhejiang Province
The binary high-pressure gradient pump system can withstand high pressure and wear.
Number of solvents: binary
Infusion principle: pump head merging, high-pressure mixing technology, dual plunger reciprocating pump, electronic pulse suppression;
Pulse suppression method: high-speed feedback, real-time control
Gradient mode: binary high-pressure gradient, mixed after pumping, greatly reducing the entry of bubbles;
Flow rate range: 0.001-50ml/min, incremental 0.001ml/min
2.1.6 Flow rate precision: ≤ 0.1%RSD
Flow velocity accuracy: ≤ ±0.15%
Maximum infusion pressure: ≥ 30Mpa
Pressure pulsation: 0.5%, at 10Mpa 5mL/min
Piston cleaning: cleaning after pump head
Control mode: RS232 or LAN
Display: ≥ 5.0-inch touch screen, each pump can be independently controlled using the touch screen
The panel is equipped with alarm, standby, and running status indicator lights, which clearly indicate the operating status of each pump.
2. UV detector
Light source: standard deuterium lamp, optional tungsten lamp
Wavelength range: 190-700nm (190-400 deuterium lamp, 400-700 tungsten lamp, standard deuterium lamp)
Wavelength accuracy: ≤ ±1nm
2.2.4 Noise (static):< 1×10-5AU
2.2.5 Drift (static):< 1.0×10-4AU/hr
Spectral bandwidth: 8nm
Optical system: dual beam
Automatic zeroing: Yes
Linear range: 0-5 AU
Wavelength repeatability: ≤ 0.2nm
Control mode: RS232 or LAN
Display: ≥ 5.0-inch touch screen, can be independently controlled using the touch screen to view device information.
The panel is equipped with alarm, standby, and running status indicator lights, which clearly indicate the operating status.
3. Chromatography workstation
It is software developed based on Windows 32-bit system, compatible with Windows XP/Windows 7/Windows 10 operating system, graphical user interface, and window operation style
Fully support GLP/FDA-21CFR Part 11 electronic signature authentication, data validity and security, system authentication tools (IQ/OQ), and system suitability testing (SST).
A universal chromatographic workstation that can obtain analysis results online and is suitable for multiple users.
It can provide timely analysis of condition parameters and analysis results, and real-time online monitoring and collection of pump pressure change data.
It has the function of tracing instrument related data and operating conditions, which facilitates troubleshooting.
It can be upgraded to be compatible with third-party instruments and can expand multiple detectors, such as evaporative light scattering detectors.
Experimental results can be output in formats such as PDF. Flexible calculation and easy modification. Gradient mode: Pre programmed with multiple gradient curves, divided into four types: 1 linear, 2 step, 4 concave, and 4 convex
It can automatically perform fast data collection and subsequent processing.
4. Automatic fraction collector
Automatic fraction collector is a new generation of microcomputer controlled instrument provided for laboratory automation. It can automatically collect liquid chromatography solutions in test tubes, and can choose the control mode of time period, volume, slope or peak height collection.
Classic XY structure, concise, intuitive and clear
Intuitive and visual control software:
Manual collection or automatic collection can be achieved through software
Multiple collection modes. Distillates can be collected based on time, peak value, slope, or volume
Can be used for assembly of different brands or complete sets of chromatography/chromatography systems, compatible with different detectors
Easy installation, safe and reliable performance, low noise, and simple maintenance
External pipeline design to minimize dead volume and reduce collection errors caused by diffusion as much as possible
Collection preview function, more convenient for method development and optimization
Support flow range: 1-200ml/min
Sample capacity of test tube rack: ≥ 120 positions (Φ 15x150mm, 15mL glass test tube), optional 15ml/50ml centrifuge tube test tube rack.
Control mode: RS232 or LAN.
5. Automatic sampler
Injection modes: Full Loop, Partial Loop, Micro liter (μ L Pick up)
Injection volume: programmable 0-9999 μ L (step size 1 μ L)
Injection accuracy: Full quantitative loop injection<0.3% RSD; Semi quantitative ring injection<0.5% RSD; Micro liter injection<1.0% RSD
Sample viscosity: 0.1-5 cP
Injection frequency/bottle: ≥ 9 times
Injection volume: at least 500 μ L (standard); 250, 1000, and 2500 μ L (optional)
Needle washing: Rinse and dry the inside and outside of the needle, and program the rinsing between each injection or each small bottle; 1-6 washing solvents can be selected
Injection cycle time:<60 seconds
5.9 Valve switching time: 60 milliseconds
Sample capacity: Microplate: 2 pieces; Sample bottle: 2x48 (1.5 mL), or 2x12 (10 mL) optional
2 high-pressure infusion pumps (50ml pump head)
One dual wavelength ultraviolet detector (50ml flow cell)
Gradient mixer (50ml) 1 piece
7725i manual injection valve 1
1 set of chromatography workstation
1 system startup toolkit
1 solvent tray
1 automatic sampler
4 gel purification columns
1 fully automatic fraction collector
The specific configuration shall be subject to the sales quotation