-
E-mail
www88888@VIP.126.com
-
Phone
18928441536
-
Address
3B-08, 3rd Floor, Dongcheng Building, Longtian Street, Pingshan District, Shenzhen
Shenzhen Xinouye Instrument Co., Ltd
www88888@VIP.126.com
18928441536
3B-08, 3rd Floor, Dongcheng Building, Longtian Street, Pingshan District, Shenzhen
The CS-200 colorimeter can measure the brightness and chromaticity of various luminescent products such as large-sized plasma displays, small-sized LCDs and LEDs, outdoor screens, high-voltage lamps, and instrument panels.
Product Introduction
Accuracy approximate spectrophotometer for light source incident colorimeter
The CS-200 can achieve high-precision brightness and chromaticity measurements comparable to spectroscope instruments, while retaining the simplicity, ease of use, and affordability of tristimulus instruments.
The CS-200 is equipped with 40 sensors and calculates using a spectral sensitivity characteristic curve (isochromatic function) that matches the sensitivity of the naked eye. Through this developed spectral fitting method, more accurate tristimulus values (XYZ of red, green, and blue) can be obtained than traditional tristimulus colorimeters, achieving higher precision.
It can measure a wide range of brightness levels (from low brightness of 0.01 cd/m2 to high brightness of 20000000 cd/m2, measured at an angle of 0.1 °).
Three measurement angles can be selected: 1 °, 0.2 °, and 0.1 °. The measurement angle can be switched according to the target being measured (from display devices or other objects that require measuring a large area to objects that require measuring a small area such as car audio control panels, car instrument panels, and small LCDs).
Application field
All types of light sources can be measured using CS-200, such as signal lights, traffic lights, airport lighting, lights, etc LED、 Almost all objects that emit light, such as cathode ray tubes, LCDs, PDPs, etc. Due to the development of information technology business, the demand for diversified media in the market is gradually increasing. In addition, with the launch of comprehensive digital broadcasting services, the research and development of various display devices centered on plasma display screens and LCDs has accelerated. The innovation of LED technology has brought significant breakthroughs to the development of LED products, including traffic lights, backlighting for reflective LCDs, and large-sized outdoor display screens.
New automatic mode
The new automatic mode can adjust the measurement speed based on the brightness of the object being measured. It may not be possible to obtain the necessary accuracy when measuring at certain measurement speeds, especially in low brightness situations. The new automatic mode will automatically select the measurement speed of * to provide the performance of CS-200 *, making it easier to achieve higher measurement accuracy.
main purpose
CS-200 can be used to measure the brightness and chromaticity of various optical devices such as LCD, PDP, organic EL, and FED, as well as light sources such as LED and lamps.
Main features
Wide measurement range, covering both low and high brightness.
Performance comparable to multiple spectroradiometers
The body is compact and lightweight. It can also be powered by batteries.
Measurement angle optional
Provide data management software CS-S10w standard version and optional professional version.
Other functions
The measurement and display devices can be synchronized by inputting frequency values. Measurement speed options (automatic, limited automatic, manual, ultra fast, fast, slow, and ultra slow) with backlit large LCD display and USB 1.1 communication
Data storage: 101 measured values (with 9-letter IDs) and 20 reference values
User correction: 20 channels
Main specifications
| model | CS-200 |
|---|---|
| measurement range | 0.01 - 200,000 cd/m2(Measuring angle 1 °) 0.01 - 5,000,000 cd/m2(Measuring angle 0.2 °) 0.01 - 20,000,000 cd/m2(Measuring angle 0.1 °) |
| accuracy (Measuring angle 1 °) # 1 (Temperature: 23 ° C ± 2 ° C, relative humidity: maximum 65%) |
150 cd/m2(For light source A): Lv ± 2% ± 1 bit; xy ±0.002 0.01-0.5 cd/m2(For light source A): Lv ± 0.02cd/m2± 1 digit; --- 0.5-1 cd/m2(For light source A): Lv ± 0.02 cd/m2± 1 digit; xy ±0.007 1-10 cd/m2(For light source A): Lv ± 2% ± 1 bit; xy ±0.004 10-200,000 cd/m2(For light source A): Lv ± 2% ± 1 bit; xy ±0.003 5000 cd/m2(For light source A): Color filter (R, G, B); xy ±0.006 |
| repetitiveness (Measuring angle 1 °) # 2 |
0.01-1 cd/m2(For light source A): Lv ± 0.01 cd/m2± position; ---(2 σ/automatic) 1-2 cd/m2(For light source A): Lv ± 0.5% ± 1 bit; Xy ± 0.002 (2 σ/automatic) 2-4 cd/m2(For light source A): Lv ± 0.5% ± 1 bit; Xy 0.001 (4 σ/automatic) 2-8 cd/m2(For light source A): Lv ± 0.5% ± 1 bit; Xy 0.0005 (8 σ/automatic) 2-200,000 cd/m2(For light source A): Lv ± 0.1% ± 1 bit; Xy 0.0004 (2 σ/automatic) |
| measure time | Automatically set between 1 second and 60 seconds (automatic); Automatically set to 1 second or 3 seconds (limited automatic) 0.5 seconds/time (super fast) 1 second/time (fast) 3 seconds/time (slow speed) 12 seconds/time (ultra slow) |
| measurement method | Spectral method, grating+linear photodiode array |
| measure angle | 1 °, 0.2 °, 0.1 ° (switchable) |
| Zui small measurement area | 0.5 mm 0.1 mm (close-up shot) |
| Zui small measurement distance | 296 mm (distance to the front edge of the metal lens barrel) |
| Observation conditions | 2/10 degrees |
| Color space | Lv x y、Lv u' v'、Lv TΔuv、XYZ、 dominant wavelength |
| Measurement synchronization setting range | Vertical synchronization frequency: 40.00~200.00Hz |
| interface | USB 1.1 |
| power supply | AC adapter or 4 AA batteries |
| Battery lifespan | Approximately 3 hours (continuous measurement/fast mode/AA type alkaline battery) |
| size | 95 mm (W) × 127 mm (H) × 330 mm (L) |
| weight | 1.8 kg (excluding battery) |
| Temperature/humidity range for use | 0-40 ° C, relative humidity below 85% (35 ° C), no condensation allowed |
| Storage temperature/humidity range | 0-45 ° C, relative humidity below 85% (35 ° C), no condensation allowed |
#1
23°C±2C Lv = 0.01-10 cd/m2Slow mode, average of 30 measurements
Lv = 10 cd/m2Above, slow mode, average of 10 measurements
#2
When the measurement angle is 0.2 °, the received light amount is approximately 1/25 of that at 1 °.
Therefore, the brightness targeted by the same repeatability is 25 times lower than that at 1 °.
When the measurement angle is 0.1 °, the received light amount is approximately 1/100 of that at 1 °.
Therefore, the brightness targeted by the same repeatability is 100 times lower than that at 1 °.
oscilloscope |
network tester |
Battery tester |
thermo-hygrometer |
illuminance meter |
Comprehensive Tester |
Signal Source Series |
illuminance meter |
multimeter |
electronic load |
LCR bridge |
Gaussmeter |
spectrum analyzer |
Grounding resistance tester |
Logic Analyzer |
sound level meter |
Safety Compliance Tester |
Insulation resistance tester |
clamp meter |
Coating thickness gauge |
power meter |
Power supply/variable frequency power supply |
gas detector |
Push-pull force gauge |