1. On site with backlit large screen and multi parameter LCD display. 2. Replacing the sensor does not require on-site calibration, and the sensor automatically recognizes it. 3. Full range temperature digital automatic tracking compensation ensures measurement accuracy. 4. Full software calibration function, users can also calibrate themselves. 5. Secondary alarm setting, dual relay signal output: two sets of passive signal output. 6. Standard 4-20mA output, transmission distance<1km; Standard RS485 signal: standard MODBUS RTU protocol, transmission distance<1km. 7. It has functions such as overvoltage protection, lightning protection, short circuit protection, reverse connection protection, anti-static interference, and anti magnetic field interference. 8. Optional 1: On site sound and light alarm. Option 2: Infrared remote control, no need to open the cover to set parameters in explosion-proof places. The detector and infrared remote control can receive up to 8 meters, ensuring safe and reliable operation. |
Application scenarios
1. Widely used in on-site testing of various places such as petrochemicals, coal, metallurgy, chemical industry, municipal gas, environmental monitoring, etc.
2. Can meet the measurement needs of special occasions;
3. It can detect gas concentration or leakage in tunnels, pipelines, tanks, enclosed spaces, etc.
4. Engineering projects in pharmaceuticals, biopharmaceuticals, chemical research, etc
Product Parameters
Product model: K-G60
Brand: Kailu Electronics
Sensors: Supports electrochemical, catalytic combustion, semiconductor, PID photoionization, infrared gas sensors
Explosion proof certificate number: CNEx18.2259X
Explosion proof mark: Ex d IIC T6 Gb/Ex tD A21 IP65 T80 ℃
Response time:<20 seconds
Working voltage: DC24V ± 15%
Working temperature: -20 ℃~50 ℃
Output current: 4-20mA
Working humidity: ≤ 95% RH, no condensation or dew
Relay control: Two sets of relay outputs, contact capacity: 30VDC 2A/220VAC 2A
Signal output: 3-wire 4-20mA; 4-wire RS485; Optional 433MHz wireless transmission function
Installation methods: wall mounted, pipe mounted, flow-through, pump suction installation
Shell material: die cast aluminum, explosion-proof and corrosion-resistant
Dimensions: 200x181x90mm (length x width x thickness)
Zero drift: ≤± 1% (F.S/year)
Detection accuracy: ≤± 3% F.S
Response time: ≤ 20 seconds (T90)
Linear error:≤±1%F.S
Protection level: IP66
Cable usage: 3 × 1.5mm2 shielded cable
Connection method: M20 × 1.5 G1/2
Instrument weight: 1.6kg
Execution standards: GB 3836.1-2010, GB 3836.4-2010, JJG693-2011, JJG551-2003, JJG915-2008, JJG365-2008