Jensprima Online Water Quality Hardness Alarm Device

NegotiableUpdate on 01/22
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The JENSPRIMA PACON 4600 online water hardness alarm is a new and reliable alarm device launched by JENSPRIMA, which can provide reliable analysis according to your requirements. Select different hardness reagents for communication to determine the required alarm points. Measure and control alarm points at fixed time intervals, and if the measured value exceeds the alarm value, the contact signal will be transmitted to the controller. Widely used for regeneration triggering that requires control and monitoring of condensate water recirculation in boiler rooms.

Product Details

Jensprima Online Water Quality Hardness Alarm DevicePACON 4600 Product Features

Fully automatic measurement

According to the selected reagent, fully automatic online measurement of the total hardness of water quality at different alarm points. This analysis process is more effective than manual measurement and more consistently reliable than other indirect measurement methods such as ion selective electrodes.

Intelligent, accurate, and stable

This alarm does not require calibration, as it uses integrated measurement technology and a two-stage analysis program (blank sample/colorimetric), it can automatically detect and eliminate external measurement effects caused by contamination of the measurement tank, turbidity of the sample, and external light effects, and eliminate these effects during the analysis process.

self-calibration

The JENSPRIMA reagent can reliably detect alarm values, and selecting the reagent that matches the alarm value is sufficient without further configuration or calibration. 500ml of reagent can perform over 5000 measurements.

Less maintenance workload

The water sample and detection device are isolated from water and electricity, and the instrument has a longer service life. Detachable measuring slot, does not require additional tools for maintenance, and can be easily executed. It is recommended to replace the spare parts package (including peristaltic pump head, reagent connecting tube, agitator, sealing ring, order number: 50-5000-10) once a year.

Multiple measurement modes

Continuous measurement, interval measurement (5-360min), external signal control measurement.

high precision

After the measurement exceeds the alarm value, reference measurement can be performed, and the evaluation results should be conducted every 4 minutes to prevent false alarms caused by negative ion effects.

Compact design/4kg

The size is only 300x300x200mm, which can be directly hung on the wall or installed on a bracket.

LCD backlit LCD display

Multi language graphic backlit LCD display for alarm status, reagent remaining amount, alarm value, and relay status.

Three passive relay outputs

Passive relay output can be used as a signal for alarm points, equipment faults, and analysis status

SD card data storage

2G data storage card, can be directly imported into the computer to view historical data and system fault information in Excel format.

Jensprima Online Water Quality Hardness Alarm DevicePACON 4600 Technical Parameters

Measurement principle: titration colorimetric method

Measurement time: about 3 minutes, depending on the hardness of the water and the set flushing time

Analysis cycle: continuous measurement/interval measurement (5-360min)/external control signal

Rinse time: Rinse time: 15-1800s

Reagent consumption:<0.1ml/analysis, 500ml can be used 5000 times

Water consumption: approximately 1000ml/analysis, depending on water sample pressure and flushing time

Display: Backlit LCD displays graphics, alarm status, and relay status

Optional units: mmol/L, ppm CaCO3, ° dH, ° f, ° e, etc

Relay output: 3-channel passive relay output NC/NO, 250VAC 4A

Signal: Alarm output, system malfunction, under analysis

Signal input: - Start analysis

-Flow switch

-Instrument reset

Data storage: -100 sets of historical curves, which can be directly viewed on the instrument

-4G SD card, can be imported into the computer to view historical data and system fault information

Basic Parameters

Environmental temperature: 5-45 ℃

Water sample temperature: 5-40 ℃

Water sample pressure: 0.5-5 bar, recommended 1-2 bar, if it exceeds 2 bar, it is recommended to install a pressure reducing valve

Water quality requirements: transparent, colorless, no suspended solids, no bubbles

pH 4 - 10.5, Iron:<3ppm, copper:<0.2ppm, aluminum:<0.1ppm, manganese:<0.2ppm

Inlet/outlet connection: Inlet/outlet connection: outer diameter 6mm hose

Humidity: 20-90% RH, indoor installation

Power supply: 85-265VAC, 50/60Hz, 25VA (during operation)

Size/Weight: 300 x 300 x 200mm, ca. 4Kg (including outer box)

Protection level: IP65