Japanese Magna axial probe

NegotiableUpdate on 01/23
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The Japanese Magna axial probe has higher durability compared to standard probes (transverse) and is suitable for high-frequency magnetic induction intensity testing. In addition, the axial magnetic induction intensity of the probe can also be measured, so it is appropriate to measure the magnetic induction intensity of the hollow core coil.

Product Details

Japanese Magna axial probe

feature

  1. It is a probe suitable for measuring hollow core coils
  2. Because it has higher durability compared to standard probes (horizontal type), it is more suitable for high-frequency magnetic induction intensity testing.

Note: Due to the construction of axial probes, there is a gap of 0.5mm between the measuring sensor and the object being measured, which may result in differences between the test results and those obtained using standard probes.

Instructions for use

1.
Link MG-801AXL to the Gaussian meter.

2.
Because the axial probe can measure the magnetic induction intensity in the direction of the arrow (axial direction), please make the probe perpendicular to the test object. The value displayed at this time is the test result.

3.
The arrow in the figure indicates the position of the sensor. The sensor deviates from the test point and cannot measure correctly. There is one scale every 90 degrees on the outer ring of the probe front end, for a total of four scales. Please use this scale to align the sensor position with the tested point

4.
The front-end sensor cannot be disassembled. If excessive external force is applied in the direction indicated by the arrow in the figure, it may cause damage and render it unusable, so please avoid it.

Note: Except for the above testing methods, the usage method is the same as the standard model probe, so please refer to the user manual of the Gauss meter body.
The photo of the usage method uses MG-701AXL.

Precautions for use

  1. This product is composed of precision parts. Inappropriate use or external impact may cause damage.
  2. This product is not designed to be moisture-proof or waterproof, so please do not use it in damp environments.
  3. In case of any damage or loss of benefits caused by the use of the device, or any requests from third parties, our company shall not be held responsible. Please be aware.

Japanese Magna axial probe