E-mail
abc586@126.com
-
Phone
18557702005
-
Address
No. 1, Lane 19, Songzhu Road, Songhu Village, Chengnan Street, Yueqing City, Zhejiang Province
Yueqing Aobin Instrument Co., Ltd
abc586@126.com
18557702005
No. 1, Lane 19, Songzhu Road, Songhu Village, Chengnan Street, Yueqing City, Zhejiang Province

1、 Overview of AOB195I-9X1 speed gauge for frequency converter
1.1 Purpose
AOB195I-9X1, a dedicated tachometer for frequency converters, is a new generation programmable intelligent ammeter mainly used for real-time measurement and indication of DC current in electrical circuits, and through
RS485 interface or analog transmission output interface for remote transmission of measured electricity data.
1.2 Functional Features
Adopting modular design approach and full SMT production process
Voltage and current measurement display range (or transformer multiplier) can be freely set
One channel analog transmission output function (optional), the output can be programmed to be 0-10mA, 0-20mA, 4-20mA at will
One way lower limit alarm output or two-way switch remote control output function (optional), alarm action delay time can be set arbitrarily within the range of 0-60s
RS485 communication output function (optional), using standard MODBUS-RTU communication protocol
It can simultaneously have one analog transmission, one lower limit alarm, and RS485 communication output functions
Two or four switch input status detection function (optional), combined with RS485 communication to achieve 'remote signaling' and 'telemetry' of switch status
Minimum value viewing function
3、 Technical parameters of AOB195I-9X1 dedicated tachometer for frequency converter
3.1 Measurement range of DC voltmeter: DC0-10V
3.2 Measurement range of DC ammeter: DC4-20mA
3.5 Accuracy: ± 0.5% FS ± 1 word
3.6 Sampling rate: about 3 times/s
3.7 Measurement display method: average value measurement, four digit LED digital tube effective value display
3.8 Display resolution: can be freely set to 1, 0.1, 0.01, 0.001
3.9 Input circuit power consumption: current<0.5VA, voltage<1VA
3.10 Auxiliary power supply: AC/DC85-264V 50/60Hz
3.11 Auxiliary power consumption:<3VA
3.12 Overflow indication: Display characters "HHHH" or "LLLL"
3.13 Alarm output: The upper and lower limit alarms are output by the same relay, with contact capacities of AC250V/1A and DC30V/2A
3.14 Transmission output: can be freely set to DC0-10mA, 0-20mA, or 4-20mA, with an accuracy of ± 0.5% FS, in conjunction with signal input and auxiliary
Electrical isolation between power ports
3.15 Transmission output load resistance: ≤ 300 Ω
3.16 Communication interface: RS485 serial communication, using MODBUS-RTU communication protocol
3.17 Working environment: Non corrosive environment with temperature ranging from -10 to 50 ℃ and humidity ≤ 85% RH