Industrial ovenMain technical parameters
1. Inner container size: width 1600 * height 1200 * depth 1250mm;
2. Dimensions (approximately): Width 2000 * Height 1990 * Depth 1410mm;
3. Temperature range: adjustable from room temperature+20 ℃ to 200 ℃;
4. Temperature fluctuation: ± 1 ℃;
5. Temperature uniformity: ± 3 ℃ (unloaded);
6. Heating rate: 8 ℃/min;
7. Shell temperature: The temperature rise shall not exceed+15 ℃ of the environment, except for joints and door edges.
8. Circulating wind mode: horizontal circulating air transport;
9. Power supply: three-phase five wire system, 380V, 50HZ;
10. Total power: around 30KW;
Industrial ovenCommon fault phenomena and maintenance methods
Phenomenon 1: No response when turning on the device
Reason for malfunction: The power supply does not meet the requirements
Repair method: Please ask a professional electrician to assist in solving the problem
Reason for malfunction: Electric heating tube malfunction
Repair method: If the heating wire is short circuited, replace the heating tube. If the heating wire is blown, replace the heating wire
Phenomenon 2: The temperature cannot rise
Fault cause: When the time reaches the set value, the fan does not turn, resulting in no heating and temperature rise
Repair method: readjust the timing setting value
Reason for malfunction: The fan is malfunctioning during operation
Repair method: Replace the fan
Phenomenon 3: Heating occurs, the inner container cannot circulate, and the temperature rises slowly
Reason for malfunction: The motor is not running
Repair method: Replace the motor
Phenomenon 4: There is a difference between the temperature displayed on the control board and the temperature measured by the thermometer
Reason for malfunction: Inaccurate measurement of thermometer
Repair method: The thermometer needs to be re measured after passing the inspection by the testing department
Reason for malfunction: There is a deviation in the measurement and installation position of the thermometer
Repair method: Adjust the position of the thermometer to the center of the inner cavity, and do not directly place it on the shelf for measurement.
Phenomenon 5: Abnormal jumping or static temperature display
Reason for malfunction: There is a problem with the temperature sensor
Repair method: Replace with a new matching sensor