Human body thermometer border port entry personnel information collection system
Application fields:
The information collection system for inbound personnel at border ports mainly consists of passport readers, health card scanners, *, all-in-one computers, and blackboards. The main purpose is to collect and store the passport information, health declaration card information, on-site photos, and questioning information of the inspected personnel, making it convenient for staff to query at any time.
Under normal circumstances, staff can complete the information collection of a person under inspection within 4 seconds, hence the name "Four Second Clearance System". Through this system, the existing customs clearance process of the inspection and quarantine system can be optimized, and customs clearance efficiency can be improved, which is a technological revolution in the inspection and quarantine system.
Human body thermometer border port entry personnel information collection system
Multi functional integration
·An integrated system that combines passport scanning, health declaration card collection, and infrared temperature monitoring functions
·The system operation is simple, and ideally, the staff can complete the information collection of one inspected person within 4 seconds
·The client software has high integration and can complete all information collection, processing, and output work at once
Integrated cabinet
·Balancing mobile inspection stations and fixed inspection stations
·The system is easy to install, quick to disassemble, and convenient to move
·Support wired LAN and wireless LAN data transmission
Fast and accurate temperature measurement
·Non contact rapid temperature measurement, SHOU with built-in blackbody, temperature measurement accuracy ≤± 0.3 ℃
·Body temperature detection based on facial recognition can improve temperature measurement accuracy and reduce false alarm rates
·Using an 800 × 600 high-resolution infrared detector, the imaging is clear and the visible range is large
Human body thermometer border port entry personnel information collection system
| S222 Technical Parameters | |||
| Passport reader | Image acquisition area | 127 x 96 mm | |
| sensor | CMOS 3 million pixels (2048 x 1536) | ||
| resolution | 390 dpi | ||
| light source | Multi band light source: including visible light, infrared 850nm, and ultraviolet 365nm | ||
| document recognition | Support image acquisition and information recognition of ICAO 9303 standard passports, Hong Kong and Macao passes, and Taiwan, China passes | ||
| data communication | USB 2.0 | ||
| auto-trigger | Support automatic sensing of identification documents to trigger document recognition | ||
| Health card scanner | type | Feed paper type | |
| Scanning components | CCD x 2 | ||
| scanning area | B5 | ||
| resolution | 600 x 1200dpi | ||
| speed | 60ppm/80ipm | ||
| data communication | USB 2.0 | ||
| Infrared Thermometer | detector | type | Vanadium oxide uncooled focal plane |
| resolution | 400X300 | ||
| Infrared lens | operating band | 8~14µm | |
| focal length | 15mm | ||
| F# | 1 | ||
| visible light | type | Digital high-definition integrated camera | |
| resolution | ≥ 2 million pixels | ||
| Frame rate | ≥25Hz | ||
| lens | 2.8-12mm, 4x optical zoom | ||
| Temperature measurement range | -10℃~50℃ | ||
| Temperature measurement accuracy | -10~20℃:≤±2℃; 20~33℃:≤±0.6; 33~37℃≤±0.3℃; 37~50℃:≤±0.6℃ | ||
| all-in-one computer | screen size | 23.6″ | |
| Screen Type | touch screen | ||
| CPU | I7 processor | ||
| memory | ≥8G | ||
| hard disk | 120GB solid-state drive+1TB mechanical hard drive | ||
| graphics card | dedicated graphics card | ||
| network card | Built in wired and wireless network cards | ||
| Media equipment | Built in sound card and speaker | ||
| boldface | Heating element | TEC | |
| The target size is | 40mm X 40mm | ||
| Power supply communication method | USB | ||
| Temperature stability accuracy | ≤±0.3℃ | ||
| Uniformity of target surface | ≤0.3℃ | ||
| environmental parameters | Operating Temperature | 0℃~45℃ | |
| Storage temperature | -10℃~55℃ | ||
*Technical parameters are for reference only. If there are any changes, the actual parameters shall prevail without further notice.