High and low temperature test chamber

NegotiableUpdate on 01/22
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Usage conditions for high and low temperature test chamber: 1. Environmental temperature: 5 ℃~+28 ℃ (average temperature within 24 hours ≤ 28 ℃) 2. Environmental humidity: ≤ 85% 3. Power requirements: AC380 (10%) V/50HZ three-phase four wire system 4. Instrument, easy to operate and set. After inputting the data and experimental conditions, the controller has a locking function to prevent human touch from changing the temperature value. 6. It has the function of P.I.D automatic calculation, which can immediately correct temperature change conditions, making temperature control more accurate and stable. 7. Optional printer.

Product Details

High and low temperature test chamberProduct Specification: ADX-GD-800A
1. Inner box size (cm) W × H × D 100 × 100 × 80 (800 type)
2. Outer box size (cm) 155 × 210 × 140 (800 type)
High and low temperature test chamberTechnical Specifications:
1. Temperature range: -40 ℃ to 150 ℃
2. Temperature fluctuation: ≤± 0.5 ℃
3. Temperature uniformity: ≤± 2 ℃
4. Temperature deviation: ≤± 1.5 ℃
5. Heating rate: 3 ℃/min
6. Cooling rate: 1 ℃/min
7. Time setting range: 0-9999 hours
8. Power requirement: AC380 (± 10%) V/50HZ? three-phase five-wire system
800L box material:
1. The shell is processed and formed using high-quality A3 steel plate CNC machine tools, and the surface of the shell is treated with anti-static spray coating, making it more smooth and beautiful;
2. The inner liner is made of high-quality SUS304 mirror stainless steel plate;
3. The insulation material is high-density glass fiber cotton with a thickness of 100mm;
4. The temperature circulation system adopts a specially designed low-noise long axis fan motor with stainless steel multi blade impellers that are resistant to high and low temperatures, to achieve strong convection and vertical diffusion circulation;
5. A double-layer high-temperature resistant high tensile sealing strip is used between the door and the box to ensure the sealing of the testing area;
6. Adopting non reactive door handles makes operation easier;
7. The bottom of the machine adopts high-quality fixed PU movable wheels;
8. The observation window adopts multi-layer insulated tempered glass, and the inner side is coated with laminated conductive film for heating and defrosting (clearly observe the test process);
9. The test hole (on the left side of the machine) can be used for external testing power or signal lines (the aperture or number of holes needs to be increased and indicated);
Wuhan control system (users can choose according to their own requirements):
1. You can choose a fully imported 5.7-inch touch sensitive temperature and humidity TEMI880 controller
2. You can choose a 1.5-inch temperature and humidity TEMI580 controller with a fully imported small touch screen
3. You can choose to use the blue screen TEMI300 temperature and humidity controller
4. You can choose a button type KR-K temperature and humidity controller
Heating system:
1. Adopting far-infrared nickel alloy high-speed heating electric heater;
2. High temperature independent system, does not affect low-temperature testing;
3. The temperature control output power is calculated by a microcomputer to achieve high-precision and high-efficiency electricity efficiency;
Refrigeration system:
1. Compressor: Fully enclosed original French Taikang unit;
2. Cooling method: single (double) mechanism cooling (air-cooled type);
3. Condensation method: forced air cooling;
4. Refrigerants: R404A, R23 (environmentally friendly);
5. All system pipelines undergo a 48 hour leak detection test with ventilation and pressurization;
6. The heating and cooling systems are independent;
7. Internal spiral refrigerant copper tube;
8. Slope evaporator;
9. The dry filter, refrigerant flow window, repair valve, oil separator, solenoid valve, and storage tank are all imported original parts;
Protection system:
1. Fan overheating protection;
2. Overall equipment under phase/reverse phase protection;
3. Overload protection for refrigeration system;
4. Refrigeration system overpressure protection;
5. Overall equipment timing;
6. Overheating of the water pump and overcurrent protection;
7. Other protections include leakage, water shortage, operation indication, automatic shutdown after fault alarm, etc;