E-mail
554377110@qq.com
-
Phone
15201768300
-
Address
No. 329 Yangyue Road, Yangwang Economic Park, Fengxian District, Shanghai
Shanghai Xiangfeng Experimental Instrument Equipment Factory
554377110@qq.com
15201768300
No. 329 Yangyue Road, Yangwang Economic Park, Fengxian District, Shanghai
High and low temperature impact test chamber
Product Usage
The high and low temperature impact test chamber is also known as a cold and hot impact machine, high and low temperature impact testing machine, cold and hot impact testing machine, etc. Used in industries such as electronic and electrical components, automation parts, automotive parts, metals, plastics, etc. Test the material's ability to withstand repeated high and low temperature tensile forces, as well as the productTest the various performance indicators of its products and materials under the instantaneous change environment between high and low temperatures.
High and low temperature impact test chamber
Application field
Consumer electronics industry, optoelectronic industry, biotechnology, academic research institutions, medical insurance industry, aerospace industry, semiconductor industry, communication industry, automotive industry, information industry.
High and low temperature impact test chamber
meet the standard
At the bottomGJB150.5A Temperature Shock Test
At the bottomGB/2423.13-2002 Temperature Shock Test
At the bottomGJB360B temperature shock test
At the bottomGB2423.1-2008/IEC6008-2-1-2007 Low temperature test methods
At the bottomGBT2423.2-2008 High temperature experimental methods
At the bottomGBT10589-2008 Technical Conditions for Low Temperature Test Chamber
At the bottomGBT11158-2008 Technical Specifications for High Temperature Test Chamber
At the bottomBS EN 2591-323-1998 Electrical and optical connecting components, temperature shock test
At the bottomGJB 595.4-1988 Environmental testing methods for artillery optical instruments - Temperature shock test
At the bottomGJB 150.5-1986 Environmental testing methods for military equipment - Temperature shock test
At the bottomGJB 797.4-1990 Environmental testing methods for rupture equipment - Temperature shock test
At the bottomHB 5830.10-1984 Environmental conditions and test methods for airborne equipment - Temperature shock test
At the bottomQJ 1177.5-1987 Environmental Test Methods for Ground to Air and Ship to Air Important Weapon Systems - Temperature Shock Test
At the bottomQJ 1184.3-1987 Important Environmental Specification for Coastal Defense - Temperature Shock Test for Onboard Equipment
At the bottomSJ 20115.3-1992 Airborne Radar Environmental Conditions and Test Methods Temperature Shock Test
At the bottomWJ 1743.4-1987 1301 Fire Extinguishing Bottle Environmental Test
At the bottomRelevant standard requirements and the "Technical Agreement" signed by both parties
High and low temperature impact test chamber
Technical Specifications
Other sizes can be customized | |||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||
|
sex can ginseng number |
high-temperature chamber |
Preheating temperature range+60 ℃~+200 ℃ Heating rate+60 ℃~+200 ℃ About 25 minutes |
|||||||||||||||||||||||||||||
Low temperature chamber |
Pre cooling temperature range -70 ℃~0 ℃ cooling rate+20 ℃~-70 ℃ for about 55 minutes |
||||||||||||||||||||||||||||||
temperature range |
-70~200℃ |
||||||||||||||||||||||||||||||
Impact range |
-40-80 ℃ (national standard requirement)/-45~80 ℃ (national military standard requirement) |
||||||||||||||||||||||||||||||
Test piece conversion time |
≤ 15 seconds |
||||||||||||||||||||||||||||||
Temperature recovery time |
≤5min |
||||||||||||||||||||||||||||||
volatility |
Temperature ≤± 0.5 ℃ |
||||||||||||||||||||||||||||||
Uniformity |
Temperature ≤±2.0℃ |
||||||||||||||||||||||||||||||
Analysis accuracy |
Temperature: 0.1 ℃ |
||||||||||||||||||||||||||||||
load capacity |
10~25KG |
||||||||||||||||||||||||||||||
|
box body material quality |
whole |
It is processed and formed using CNC machine tools, with a beautiful and elegant appearance, and adopts a non reactive handle for easy operation. |
|||||||||||||||||||||||||||||
inner liner |
1.2mm thick SUS304 high-grade stainless steel brushed/mirror finish. |
||||||||||||||||||||||||||||||
shell |
The 1.5mm thick cold-rolled plate baked paint outer shell adopts A3 steel plate spray coating, which increases the appearance texture and cleanliness. |
||||||||||||||||||||||||||||||
insulation layer |
100mm thick ultra-fine fiber or polyurethane hard foam can avoid unnecessary energy loss |
||||||||||||||||||||||||||||||
seal |
Double layer high tensile sealing strips with high temperature resistance are used between the box door and the box body to ensure the sealing of the testing area |
||||||||||||||||||||||||||||||
Door frame insulation |
Double layer high and low temperature aging resistant silicone rubber door sealing strip |
||||||||||||||||||||||||||||||
observation window |
Made of 4-layer insulated tempered glass with automatic defrosting and thermal conductivity function, allowing for clear observation of the internal test items |
||||||||||||||||||||||||||||||
lighting lamp |
Equipped with explosion-proof, high and low temperature resistant lighting devices |
||||||||||||||||||||||||||||||
caster |
test chamberThe bottom of the box adopts high-quality fixed PU movable wheels for easy movement |
||||||||||||||||||||||||||||||
|
manufacture cold be unify |
refrigeration system |
To ensure the cooling rate and low temperature requirements of the test chamber, a single-stage/two-stage refrigeration system is adopted |
|||||||||||||||||||||||||||||
compressor |
Adopting the century old "Taikang" fully enclosed refrigeration compressor unit, each unit is monitored item by item through the European "Taikang" computer network and has anti-counterfeiting codes, which can be searched online through computers/Gulun compressors/Bitzer compressors |
||||||||||||||||||||||||||||||
Refrigeration auxiliary components |
The air-cooled coil condenser and finned multi-stage evaporator are mainly equipped with imported components for refrigeration and control, such as the Danish "Danfoss" thermal expansion valve and the American "Aigo" drying filter; Italian "Castello" solenoid valve; |
||||||||||||||||||||||||||||||
refrigerant |
A404/R23 |
||||||||||||||||||||||||||||||
cooling method |
Air cooling |
||||||||||||||||||||||||||||||
Vibration reduction and noise reduction |
Vibration and noise reduction measures for refrigeration system |
||||||||||||||||||||||||||||||
|
control manufacture be unify |
Temperature controller analysis accuracy ± 0.1 ℃ |
||||||||||||||||||||||||||||||
7.0 "true color touch screen/Chinese or English input/historical curve recording/PID self-tuning/programming loop | |||||||||||||||||||||||||||||||
Imported LED digital display P, I, D+S, S, R. microcomputer integrated controller | |||||||||||||||||||||||||||||||
Temperature sensor: Platinum resistance PT100 armored, high precision and accuracy | |||||||||||||||||||||||||||||||
|
follow ring be unify |
Temperature resistant and low-noise air conditioning motor, multi blade centrifugal fan. |
||||||||||||||||||||||||||||||
Adopting a multi wing air supply fan for strong air circulation, avoiding any dead corners, can make the temperature distribution in the testing area uniform. | |||||||||||||||||||||||||||||||
Heating, cooling, and system independence can improve efficiency, reduce testing costs, extend lifespan, and decrease failure rates. | |||||||||||||||||||||||||||||||
The design of wind path circulation for air outlet and return ensures that the wind pressure and speed meet the testing standards, and can quickly stabilize the temperature at the moment of opening the door. | |||||||||||||||||||||||||||||||
heating system |
Nickel chromium alloy electric heating finned heating tube |
||||||||||||||||||||||||||||||
Standard Configuration |
1 set of observation window, 50mm cable holes (size and number can be customized), power cord, instruction manual, certificate of conformity |
||||||||||||||||||||||||||||||
safety protection |
Overtemperature alarm, leakage protection, overcurrent protection, fast fuse, compressor high and low voltage protection, compressor overheating protection, compressor overcurrent protection, line fuse and fully sheathed terminal, water shortage protection, grounding protection |
||||||||||||||||||||||||||||||
power supply voltage |
380V 50HZ three-phase five wire system |
||||||||||||||||||||||||||||||
|
two-box (car body style) impact feature |
The two box equipment is divided into two parts: high temperature zone and low temperature zone. The test product is placed in a basket, and when impacted, the basket moves the test product closer to the high temperature zone or low temperature zone for impact. The test product is dynamic. Adopting a touch sensitive operation interface, TEMI8229 is easy to operate, with an impact box instrument and intelligent operation. The impact method applies the air path switching method to import the temperature into the testing area for conducting cold and hot impact tests. When subjected to high or low temperature impact, the maximum duration can reach 999H, and the maximum cycle time can reach 9999 times. The system can automatically cycle or manually selectively impact. The cooling effect is fast, and it is not possible to test the impact at room temperature. |
||||||||||||||||||||||||||||||
|
Three compartments impact feature |
The two door equipment is divided into three parts: high temperature zone, low temperature zone, and test zone. The test product is placed in the test zone, and the temperature of the high or low temperature zone enters the test zone for impact. The test product is static. Adopting a touch sensitive operation interface, TEMI8229 is easy to operate, with an impact box instrument and intelligent operation. The impact method applies the air path switching method to import the temperature into the testing area for conducting cold and hot impact tests. When subjected to high or low temperature impact, the maximum duration can reach 999H, and the maximum cycle time can reach 9999 times. The system can automatically cycle or manually select shocks, and can set the start of second or third zone shocks and cold and hot shocks. The cooling effect is fast and can be experimentally impacted to room temperature. |
||||||||||||||||||||||||||||||
Two door test method and three door test principle | |||||||||||||||||||||||||||||||