Product Introduction
The Medium touch series uses urban tap water as its source of water and can easily and quickly manufacture RO reverse osmosis water, DI deionized water, and UP ultrapure water. Based on Medium, it has undergone comprehensive system optimization and technological upgrades, integrating a touch screen control system and adding dual quantitative water intake functions. It is positioned to provide pure water solutions for central laboratories, building water supply, pilot workshops, small production workshops, and related areas with high water consumption.
There are currently 7 sub product series of Medium Touch-Q/S/RO/RQ/RS/1600Q/1600S, with a system water production range of 45-250 liters/hour and an ultra pure water resistance rate of 18.2M Ω. cm, which meets the water quality standards set by GB/T 6682-2008, GB/T33087-2016, ASTM, CAP, CLSI, EP, and USP.
Features and Advantages
5.0-inch color touch screen, animated menu, realizing a new experience of fingertip touch operation
3-channel water quality monitoring, real-time monitoring of source water, RO reverse osmosis water, DI deionized water/UP ultrapure water quality, no need to take water to view water quality
2-channel quantitative (10-999999ml) and qualitative (1-18.25M Ω· cm) water intake function
The ultrapure water circulation system can be freely started and shut down to maintain a low level of bacterial contamination in the system
Ultra pure water full pipeline disinfection program, which can manually perform "cycle disinfection", "water intake disinfection", "water tank replenishment", "manual sewage discharge", and "stop disinfection"
The lifespan of consumables such as PP, KDF, AC, RO, UP, UF, TF, and UV can be set, and the used time can be displayed. Automatic reminders for replacement will be given upon expiration
System time setting (year/month/day/hour/minute), timed standby (0-60min), timed shutdown (0-24h) function
Water shortage, full water alarm, source water, RO reverse osmosis water, DI deionized water/UP ultrapure water exceeding standard alarm
Compatible with two pure water storage methods: pressure water tank and liquid level water tank, it can directly display the water storage capacity of the water tank to meet different application needs
Factory and customer secondary passwords, system settings are protected by passwords to prevent unauthorized changes
Fully automatic RO membrane anti scaling flushing (adjustable flushing interval and duration) and manual forced flushing program to extend the service life of RO membrane
Record and check the replacement time of consumables at any time, comprehensively grasp equipment maintenance information
Complete information query and data management functions, comprehensively control system operation status, water quality, consumables usage, timely alarm, historical alarm and other information
The system comes with a built-in storage card that automatically records one year's operational data. The time range can be set and complete data export can be performed through a USB interface
Built in 2 15 liter pressure water tanks, saving laboratory space and making installation and maintenance more convenient. An external large capacity water storage tank can be added to meet different water volume needs
Stainless steel spray painted chassis to prevent corrosion and rust, ensuring the cleanliness of the body and complying with GLP standards
Floor standing design with movable and fixed feet at the bottom, making installation and movement more convenient
Internal reserved space for installing a circulating conveying system as a water supply equipment.
Pure water pipelines and fittings have obtained NSF certification
Optimized RO membrane module design, using Dow DOW * RO membrane from the United States, achieves the combination of long lifespan of RO membrane and high-quality water quality
Large capacity ultra purification column technology, which can significantly improve water quality with a small amount of resin, uses Dow * nuclear grade resin from the United States to ensure the quality of pure water at all times
Dual wavelength (185nm&254nm) UV lamp components (imported lamp tubes) effectively sterilize, reduce TOC, and enhance system applicability
MWCO5000DUF ultrafiltration module (*) effectively removes endotoxins (i.e. pyrogens) and can be used for precision cell culture and IVF
0.2 μ m imported PES polyether sulfone composite membrane terminal sterilization filter, ensuring sterile water quality
Technical Specifications
| Medium Touch-Q Deionized Pure Water Machine | ||||||
| model | water production | resistivity | conductivity | Heavy metal ions | bacteria | Particulate matter (>0.2 μ m) |
| Medium touch-Q300 | 45 liters per hour | 10-18.2MΩ.cm | 0.1-0.055 μs/cm | <0.1 ppb | <0.01 cfu/ml | <1/ml |
| Medium touch-Q400 | 63 liters per hour | 10-18.2MΩ.cm | 0.1-0.055 μs/cm | <0.1 ppb | <0.01 cfu/ml | <1/ml |
| Medium touch-Q600 | 94 liters per hour | 10-18.2MΩ.cm | 0.1-0.055 μs/cm | <0.1 ppb | <0.01 cfu/ml | <1/ml |
| Medium touch-Q800 | 125 liters per hour | 10-18.2MΩ.cm | 0.1-0.055 μs/cm | <0.1 ppb | <0.01 cfu/ml | <1/ml |
| Medium Touch-S Ultra Pure Water Machine | |||||||||
| model | water production | resistivity | heavy metal ions | Total Organic Carbon (TOC) | bacteria | heat source | particulate matter | Ribonuclease | Deoxyribonuclease |
| (endotoxin) | (>0.1μm) | (RNases) | (DNases) | ||||||
| Medium touch- | 45, 63, 94, 125 liters/hour | 18.2MΩ .cm@25 ℃ | <0.01 | <10 | <0.01 | N/A | <1/ml | N/A | N/A |
| S300/400/600/800 | ppb | ppb | cfu/ml | ||||||
| Medium touch- | 45, 63, 94, 125 liters/hour | 18.2MΩ .cm@25 ℃ | <0.01 | <10 | <0.01 | <0.001 | <1/ml | <1 | <5 |
| S300/400/600/800UF | ppb | ppb | cfu/ml | Eu/ml | pg/ml | pg/ml | |||
| Medium touch- | 45, 63, 94, 125 liters/hour | 18.2MΩ .cm@25 ℃ | <0.01 | <3 | <0.01 | N/A | <1/ml | N/A | N/A |
| S300/400/600/800UV | ppb | ppb | cfu/ml | ||||||
| Medium touch- | 45, 63, 94, 125 liters/hour | 18.2MΩ .cm@25 ℃ | <0.01 | <3 | <0.01 | <0.001 | <1/ml | <1 | <5 |
| S300/400/600/800UVF | ppb | ppb | cfu/ml | Eu/ml | pg/ml | pg/ml | |||
| Medium touch-R two-stage reverse osmosis pure water/ultrapure water machine | ||
| model | water production | Other pure water indicators |
| Medium-RO | 30, 45, 60, 90 liters/hour | RO series: |
| 30/45/60/90 | Primary RO water (TDS): conductivity ≈ source water conductivity × 5%, secondary RO water (TDS): 1-5 μ s/cm (conductivity ≤ source water conductivity × 2%) | |
| Organic matter retention rate>99% (when MW>200 daltons); Particle and bacterial retention rate>99% | ||
| Medium-RQ | 30, 45, 60, 90 liters/hour | RQ series: |
| 30/45/60/90 | Electrical resistivity: 10-18.2M Ω· cm, heavy metal ions<0.01 ppb, bacteria<0.01 cfu/ml, particulate matter (>0.2 μ m)<1/ml | |
| Medium-RS | 30, 45, 60, 90 liters/hour | RS series: |
| 30/45/60/90 UF/UV/UVF | Electrical resistivity: 18.2M Ω .cm@25 ℃, heavy metal ions<0.01 ppb, bacteria<0.01 cfu/ml, particulate matter (>0.2 μ m)<1/ml, total organic carbon (TOC)<10 ppb * * * (UV/UVF type: TOC<3 ppb * * *), UF/UVF type: heat source<0.001 Eu/ml, ribonucleases (RNases)<1pg/ml, deoxyribonucleases (DNases)<5pg/ml | |
*The quality of incoming water will affect the quality of pure water and the lifespan of the filter column