Welcome Customer !

Membership

Help

Shanghai Hetai Instrument Co., Ltd
Custom manufacturer

Main Products:

mechb2b>Products

Hetai Full Touch Screen Pure Water/Ultra Pure Water Machine

NegotiableUpdate on 01/25
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The Medium touch series uses urban tap water as its source of water and can easily and quickly manufacture RO reverse osmosis water, DI deionized water, and UP ultrapure water. Based on Medium, it has undergone comprehensive system optimization and technological upgrades, integrating a touch screen control system and adding dual quantitative water intake functions. It is positioned to provide pure water solutions for central laboratories, building water supply, pilot workshops, small production workshops, and related areas with high water consumption. There are currently 7 sub product series of Medium Touch-Q/S/RO/RQ/RS/1600Q/1600S.

Product Details

Product Introduction

The Medium touch series uses urban tap water as its source of water and can easily and quickly manufacture RO reverse osmosis water, DI deionized water, and UP ultrapure water. Based on Medium, it has undergone comprehensive system optimization and technological upgrades, integrating a touch screen control system and adding dual quantitative water intake functions. It is positioned to provide pure water solutions for central laboratories, building water supply, pilot workshops, small production workshops, and related areas with high water consumption.

There are currently 7 sub product series of Medium Touch-Q/S/RO/RQ/RS/1600Q/1600S, with a system water production range of 45-250 liters/hour and an ultra pure water resistance rate of 18.2M Ω. cm, which meets the water quality standards set by GB/T 6682-2008, GB/T33087-2016, ASTM, CAP, CLSI, EP, and USP.

Features and Advantages

5.0-inch color touch screen, animated menu, realizing a new experience of fingertip touch operation

3-channel water quality monitoring, real-time monitoring of source water, RO reverse osmosis water, DI deionized water/UP ultrapure water quality, no need to take water to view water quality

2-channel quantitative (10-999999ml) and qualitative (1-18.25M Ω· cm) water intake function

The ultrapure water circulation system can be freely started and shut down to maintain a low level of bacterial contamination in the system

Ultra pure water full pipeline disinfection program, which can manually perform "cycle disinfection", "water intake disinfection", "water tank replenishment", "manual sewage discharge", and "stop disinfection"

The lifespan of consumables such as PP, KDF, AC, RO, UP, UF, TF, and UV can be set, and the used time can be displayed. Automatic reminders for replacement will be given upon expiration

System time setting (year/month/day/hour/minute), timed standby (0-60min), timed shutdown (0-24h) function

Water shortage, full water alarm, source water, RO reverse osmosis water, DI deionized water/UP ultrapure water exceeding standard alarm

Compatible with two pure water storage methods: pressure water tank and liquid level water tank, it can directly display the water storage capacity of the water tank to meet different application needs

Factory and customer secondary passwords, system settings are protected by passwords to prevent unauthorized changes

Fully automatic RO membrane anti scaling flushing (adjustable flushing interval and duration) and manual forced flushing program to extend the service life of RO membrane

Record and check the replacement time of consumables at any time, comprehensively grasp equipment maintenance information

Complete information query and data management functions, comprehensively control system operation status, water quality, consumables usage, timely alarm, historical alarm and other information

The system comes with a built-in storage card that automatically records one year's operational data. The time range can be set and complete data export can be performed through a USB interface

Built in 2 15 liter pressure water tanks, saving laboratory space and making installation and maintenance more convenient. An external large capacity water storage tank can be added to meet different water volume needs

Stainless steel spray painted chassis to prevent corrosion and rust, ensuring the cleanliness of the body and complying with GLP standards

Floor standing design with movable and fixed feet at the bottom, making installation and movement more convenient

Internal reserved space for installing a circulating conveying system as a water supply equipment.

Pure water pipelines and fittings have obtained NSF certification

Optimized RO membrane module design, using Dow DOW * RO membrane from the United States, achieves the combination of long lifespan of RO membrane and high-quality water quality

Large capacity ultra purification column technology, which can significantly improve water quality with a small amount of resin, uses Dow * nuclear grade resin from the United States to ensure the quality of pure water at all times

Dual wavelength (185nm&254nm) UV lamp components (imported lamp tubes) effectively sterilize, reduce TOC, and enhance system applicability

MWCO5000DUF ultrafiltration module (*) effectively removes endotoxins (i.e. pyrogens) and can be used for precision cell culture and IVF

0.2 μ m imported PES polyether sulfone composite membrane terminal sterilization filter, ensuring sterile water quality

Technical Specifications

Medium Touch-Q Deionized Pure Water Machine
model water production resistivity conductivity Heavy metal ions bacteria Particulate matter (>0.2 μ m)
Medium touch-Q300 45 liters per hour 10-18.2MΩ.cm 0.1-0.055 μs/cm <0.1 ppb <0.01 cfu/ml <1/ml
Medium touch-Q400 63 liters per hour 10-18.2MΩ.cm 0.1-0.055 μs/cm <0.1 ppb <0.01 cfu/ml <1/ml
Medium touch-Q600 94 liters per hour 10-18.2MΩ.cm 0.1-0.055 μs/cm <0.1 ppb <0.01 cfu/ml <1/ml
Medium touch-Q800 125 liters per hour 10-18.2MΩ.cm 0.1-0.055 μs/cm <0.1 ppb <0.01 cfu/ml <1/ml

Medium Touch-S Ultra Pure Water Machine
model water production resistivity heavy metal ions Total Organic Carbon (TOC) bacteria heat source particulate matter Ribonuclease Deoxyribonuclease
(endotoxin) (>0.1μm) (RNases) (DNases)
Medium touch- 45, 63, 94, 125 liters/hour 18.2MΩ .cm@25 ℃ <0.01 <10 <0.01 N/A <1/ml N/A N/A
S300/400/600/800 ppb ppb cfu/ml
Medium touch- 45, 63, 94, 125 liters/hour 18.2MΩ .cm@25 ℃ <0.01 <10 <0.01 <0.001 <1/ml <1 <5
S300/400/600/800UF ppb ppb cfu/ml Eu/ml pg/ml pg/ml
Medium touch- 45, 63, 94, 125 liters/hour 18.2MΩ .cm@25 ℃ <0.01 <3 <0.01 N/A <1/ml N/A N/A
S300/400/600/800UV ppb ppb cfu/ml
Medium touch- 45, 63, 94, 125 liters/hour 18.2MΩ .cm@25 ℃ <0.01 <3 <0.01 <0.001 <1/ml <1 <5
S300/400/600/800UVF ppb ppb cfu/ml Eu/ml pg/ml pg/ml

Medium touch-R two-stage reverse osmosis pure water/ultrapure water machine
model water production Other pure water indicators
Medium-RO 30, 45, 60, 90 liters/hour RO series:
30/45/60/90 Primary RO water (TDS): conductivity ≈ source water conductivity × 5%, secondary RO water (TDS): 1-5 μ s/cm (conductivity ≤ source water conductivity × 2%)
Organic matter retention rate>99% (when MW>200 daltons); Particle and bacterial retention rate>99%
Medium-RQ 30, 45, 60, 90 liters/hour RQ series:
30/45/60/90 Electrical resistivity: 10-18.2M Ω· cm, heavy metal ions<0.01 ppb, bacteria<0.01 cfu/ml, particulate matter (>0.2 μ m)<1/ml
Medium-RS 30, 45, 60, 90 liters/hour RS series:
30/45/60/90 UF/UV/UVF Electrical resistivity: 18.2M Ω .cm@25 ℃, heavy metal ions<0.01 ppb, bacteria<0.01 cfu/ml, particulate matter (>0.2 μ m)<1/ml, total organic carbon (TOC)<10 ppb * * * (UV/UVF type: TOC<3 ppb * * *), UF/UVF type: heat source<0.001 Eu/ml, ribonucleases (RNases)<1pg/ml, deoxyribonucleases (DNases)<5pg/ml

*The quality of incoming water will affect the quality of pure water and the lifespan of the filter column