Welcome Customer !

Membership

Help

Jinhu Simite Instrument Co., Ltd
Custom manufacturer

Main Products:

mechb2b>Products

Hastelloy HC diaphragm single flange pressure transmitter DN50

NegotiableUpdate on 01/22
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The Hastelloy HC diaphragm single flange pressure transmitter DN50 has a variable capacitance sensing element that can oscillate, modulate, amplify, and convert the capacitance difference between the measuring diaphragm and the capacitor plate into a standard signal through an oscillator, modulation and demodulation, amplifier amplification, and voltage and current conversion. Can be used for measuring gases, liquids, and vapors.

Product Details

Hastelloy HC diaphragm single flange pressure transmitter DN50It has the characteristics of design principles, complete variety and specifications, and easy installation and use. Has strong universality and substitutability. In order to adapt to the continuous improvement and development of domestic automation level, this series of products not only has a compact and exquisite design, but also introduces intelligent functions with HART fieldbus protocol.
Hastelloy HC diaphragm single flange pressure transmitter DN50Main technical parameters:
Output: 4-20mA
Power supply: 24VDC; No load, the transmitter can operate at 12VDC; Great 45VDC
Accuracy: ± 0.2%, ± 0.25%, ± 0.5% of the calibration range, including comprehensive errors of linearity, variability, and repeatability.
Temperature range: The amplifier operates at -29 ℃ -+93 ℃; Sensitive components operate at -40 ℃ -+104 ℃;
Storage temperature: -50 ℃ -+120 ℃;
Relative humidity: 0-85%;
Positive and negative transfer: Regardless of the output, after positive and negative transfer, the upper and lower limits of the range must not exceed the limit of the range. The large negative transfer is 600% of the small calibration range, and the large positive transfer is 500% of the small calibration range.
Strengths Analysis
Simple structure: without any movable or elastic components, therefore reliable and requires minimal maintenance.
Easy installation: The built-in structure particularly demonstrates this feature, requiring no tools.
Easy adjustment: The zero position and range potentiometers can be used to freely shift the zero position or change the range within the effective range of liquid level detection, and the two adjustments do not affect each other.
Widely applicable; Suitable for liquid level measurement in media with high temperature, high pressure, strong corrosion, etc.
Order Model Specification Table

1151LT

Flange type liquid level transmitter

code

Range KPa

4

0-6.22 to 0-37.29kPa

5

0-31.08 to 0-186.45kPa

6

0-117.21 to 0-689.48kPa

code

output

E

4-20mA

S

Intelligent (HART protocol)

code

Nominal diameter (mm)

Insertion tube length (mm)

High pressure side diaphragm material

A0

(3〞)80

flat

316LSST

A2

(3 ") 80

50

316LSST

A4

(3 ") 80

100

316LSST

A6

(3 ") 80

150

316LSST

B0

(4〞)100

flat

316LSST

B2

(4 ") 100

50

316LSST

B4

(4 ") 100

100

316LSST

B6

(4 ") 100

150

316LSST

C0

(3〞)80

flat

Ha Shi C-276

C2

(3〞)80

50

Ha Shi C-276

C4

(3〞)80

100

Ha Shi C-276

C6

(3〞)80

150

Ha Shi C-276

D0

(4〞)100

flat

Ha Shi C-276

D2

(4〞)100

50

Ha Shi C-276

D4

(4〞)100

100

Ha Shi C-276

D6

(4〞)100

150

Ha Shi C-276

E0

(3〞)80

flat

Tantalum

F0

(4〞)100

flat

Tantalum

code

Install flange

A

3〞150lb

B

4〞150lb

C

3〞300lb

D

4〞300lb

code

Structural materials

Flanges and fittings

Exhaust/Drain Valve

Isolation membrane

Fill with liquid

22

316 stainless steel

316 stainless steel

316 stainless steel

silicone oil

23

316 stainless steel

316 stainless steel

Hastelloy C

24

316 stainless steel

316 stainless steel

Monel

25

316 stainless steel

316 stainless steel

Tantalum

33

Hastelloy C

Hastelloy C

Hastelloy C

35

Hastelloy C

Hastelloy C

Tantalum

code

option

M1

0-100% linear indicator table

M2

LCD display table

M3

LCD display table

B1

Pipe bending bracket

B2

Board mounted bending bracket

B3

Pipe mounted flat bracket

D1

The side relief valve is located at the upper part of the pressure chamber

D2

The side relief valve is located at the lower part of the pressure chamber

unnoted

1/2NPT taper pipe threaded joint

C2

T-shaped threaded joint M20 × 1.5, with rear welding of Ø 14

Spherical cone connector of pressure pipe

d

Explosion proof type d Ⅱ BT4

i

Intrinsic safety type ia Ⅱ CT6

Ordering Notice

<strong>单法兰液位变送器</strong>

1) The transmitter model can be determined according to the selection specification table as needed.
2) The numbers and symbols in the selection specification table must be filled in clearly and accurately.
3) If there is positive or negative migration, the migration amount value must be indicated.
4) If a differential pressure transmitter needs to be equipped with a three valve group, it needs to be specified separately.
5) When selecting a remote transmitter, it should also be determined according to different remote flange selection tables as needed.
6) If the remote transmitter is to be used in vacuum and high temperature environments, it should be specially marked when ordering.
7) The materials for the contact medium O-ring include nitrile rubber and fluororubber.
8) Unless otherwise specified, the filling fluid at the factory is silicone oil