HanaCODreagentHI93754 |
HannabrandCODThe reagent tube contains approximately3 mLPre made reagents, so users only need to add a small amount of sample; By using pre made reagents, the amount of chemicals and processing time are minimized, the preparation time for testing is greatly reduced, and there are no time-consuming reagent preparation procedures or glassware cleaning;CODReagent tubes and bottle caps are designed to prevent accidental spillage of reagents.
|
HI93754typeCODReagents from25Composed of customized glass reagent tubes containing pre made reagents, these high-quality pre made reagents meet the requirements ofEPAstandard410.4Method, dichromate, mercury free andISOStandard standards15705method;
Before use, it is necessary to useHI839800Heating and digestion device settings150ºC(302ºF)Perform a two-hour heating pretreatment [Do not use an oven or microwave as it may cause corrosion or explosion]; During the digestion heating process, hexavalent chromium in the pre prepared reagent is reduced to trivalent chromium.
After the digestion and heating treatment is completed, be careful to move the heating test tube toHI740216Cooling on stainless steel test tube cooling rack for approximately20More than minutes to room temperature, Then useHI801TheHI83399orHI83314 CODThe photometer is used for colorimetric measurement of the amount of reduced chromium, that isCODConcentration tomg/L(ppm)O2Display the reading.
|
|
HanaCODreagentHI93754Technical Specifications
HanaHI93754typeCODReagents includeHI93754A-25TheHI93754B-25TheHI93754C-25TheHI93754D-25TheHI93754E-25TheHI93754F-25TheHI93754G-25There are various specifications, and the specific differences are as follows:
comply withEPAstandard410.4methodCODReagent, containing mercuric sulfate(Hgso 4)To reduce the interference of high chloride content on measurement results, suitable for the wastewater and food industriesCODConcentration measurement |
|||||||||||||||
Reagent model |
Scope of Application |
resolution |
precision |
Applicable method/standard |
|||||||||||
HI93754A-25 |
0 to 150 mg/L(ppm)O2 |
1 mg/L(ppm) |
reading±5%±5 mg/L(ppm) |
EPAstandard410.4method |
|||||||||||
HI93754B-25 |
0 to 1500 mg/L(ppm)O2 |
1 mg/L(ppm) |
reading±4%±15 mg/L(ppm) |
EPAstandard410.4method |
|||||||||||
Usage guide: Take twoHI93754A-25Reagent [orHI93754B-25】, will2mLAdd deionized water into one of the test tubes and mark it as blank sample [reusable multiple times]2mLAdd the water sample to another test tube. Note that when adding deionized water or the sample to be tested, it is necessary to useHI740142Sample dispenser, glass reagent tube storage45Slowly and carefully add with a tilt angle, cover with a lid, and very carefully invert the reagent tube several times to ensure thorough mixing before placing itHI839800Heating treatment is carried out inside the digester. |
|||||||||||||||
Compliant with the dichromate methodCODReagent, this method is suitable for measuring the sample1500 mg / LO 2ofCODconcentration |
|||||||||||||||
Reagent model |
Scope of Application |
resolution |
precision |
Applicable method/standard |
|||||||||||
HI93754C-25 |
0 to 15000 mg/L(ppm)O2 |
10 mg/L(ppm) |
reading±3%±150 mg/L(ppm) |
Dichromate salt |
|||||||||||
Usage guide: Take twoHI93754C-25Reagent, will0.2mLAdd deionized water into one of the test tubes and mark it as blank sample [reusable multiple times]0.2mLAdd the water sample to another test tube. Note that when adding deionized water or the sample to be tested, it is necessary to useHI740142Sample dispenser, glass reagent tube storage45Slowly and carefully add with a tilt angle, cover with a lid, and very carefully invert the reagent tube several times to ensure thorough mixing before placing itHI839800Heating treatment is carried out inside the digester. |
|||||||||||||||
Compliant with mercury freeCODReagent, green and environmentally friendly, no need to consider handling used reagent tubes, mercury freeCODThe reagent is not suitable for measuring samples containing chloride because it does not contain mercuric sulfate |
|||||||||||||||
Reagent model |
Scope of Application |
resolution |
precision |
Applicable method/standard |
|||||||||||
HI93754D-25 |
0 to 150 mg/L(ppm)O2 |
1 mg/L(ppm) |
reading±5%±5 mg/L(ppm) |
mercury-free |
|||||||||||
HI93754E-25 |
0 to 1500 mg/L(ppm)O2 |
1 mg/L(ppm) |
reading±4%±15 mg/L(ppm) |
mercury-free |
|||||||||||
Usage guide: Take twoHI93754D-25Reagent [orHI93754E-25】, will2mLAdd deionized water into one of the test tubes and mark it as blank sample [reusable multiple times]2mLAdd the water sample to another test tube. Note that when adding deionized water or the sample to be tested, it is necessary to useHI740142Sample dispenser, glass reagent tube storage45Slowly and carefully add with a tilt angle, cover with a lid, and very carefully invert the reagent tube several times to ensure thorough mixing before placing itHI839800Heating treatment is carried out inside the digester. |
|||||||||||||||
comply withISO.15705 CODReagent, containing mercuric sulfate(Hgso 4)To reduce the interference of chloride on measurement results and ensure the stability and reliability of measurement readings |
|||||||||||||||
Reagent model |
Scope of Application |
resolution |
precision |
Applicable method/standard |
|||||||||||
HI93754F-25 |
0 to 150 mg/L(ppm)O2 |
1 mg/L(ppm) |
reading±5%±5 mg/L(ppm) |
ISOstandard15705method |
|||||||||||
HI93754G-25 |
0 to 1500 mg/L(ppm)O2 |
1 mg/L(ppm) |
reading±4%±15 mg/L(ppm) |
ISOstandard15705method |
|||||||||||
Usage guide: Take twoHI93754F-25Reagent [orHI93754G-25】, will2mLAdd deionized water into one of the test tubes and mark it as blank sample [reusable multiple times]2mLAdd the water sample to another test tube. Note that when adding deionized water or the sample to be tested, it is necessary to useHI740142Sample dispenser, glass reagent tube storage45Slowly and carefully add with a tilt angle, cover with a lid, and very carefully invert the reagent tube several times to ensure thorough mixing before placing itHI839800Heating treatment is carried out inside the digester. |
|||||||||||||||
HanaCODreagentHI93754Optional set
HI93754C-25
Customized Chemical Oxygen DemandCOD HRReagent, in accordance with the dichromate method, applicable scope:0 to 15000 mg / L(ppm)Specification:25branch/box
HI93754-25D1
Customized Chemical Oxygen DemandCODReagent kit, specifications:25branch/Box X6Warm reminder:HI93754seriesCODReagents, any combination, quantity up to six boxes/Groups can enjoy discounted prices
HI93754-25D2
Customized Chemical Oxygen DemandCODReagent kit, specifications:25branch/Box X3Warm reminder:HI93754seriesCODReagents, any combination, quantity up to three boxes/Groups can enjoy discounted prices
moreWater Quality TesterAs well as supporting reagents and consumables, please feel free to inquire with our sales personnel for more information. Recommended host for this reagent: Italy Hana COD analyzer HI83399
After sales service commitment |
1.All products are covered by a one-year warranty from the date of sale, except for consumables, in the event of non-human damage.
2.If there are any malfunctions or component damages caused by quality issues during the warranty period, our company is responsible for repairing them.
3.If there are quality problems outside the warranty period, or if the instrument components are damaged due to usage or other human factors, our company will only charge the cost of the replaced components.
4. Our company provides24Free hourly consultation and maintenance services, with a response time of4If the maintenance personnel are unable to troubleshoot the product through telephone communication, the buyer shall send the product back for maintenance, and our company shall be responsible for the postage incurred.