1. What is a gas detector?
The so-called gas detector is an instrument that can detect the concentration of gases in the air. When the detected gas concentration is lower or higher than the preset alarm value, it will generate sound and light vibration alarm to prompt the user. It is a safety instrument for industry safety management and detection, maintenance and construction personnel.
2. Choosing the appropriate gas detector for different locations and testing needs is crucial for purchasing gas detectors. Below, we will provide a brief introduction on how to choose the right gas detector for your reference and selection.
(1) Confirm the type and range of gases detected on site, such as
detect gasmeasurement range
flammable gas0-100 %LEL
oxygen0-30%VOL
carbon monoxide0-1000ppm
hydrogen sulfide0-100ppm
(2) Confirm the detection method of the detector
portableAs the name suggests, it is easy to carry and can detect gas concentration anytime and anywhere. It has a small volume with digital display, sound and light alarm functions, and can be directly tested when turned on.
fixed typeFixed at a certain leakage point, it can be continuously monitored in real-time for 24 hours, and the corresponding system can be uploaded through signal output.
If you need a portable gas detector, please continue reading Article (3) and Article (4); If you need a fixed gas detector, please read the content of (5) directly.
(3) Confirm the quantity of gas detected by the portable gas detector
ClassificationdefinitionRecommended Model
1 type of gasAn instrument can only detect one type of gas and is generally used for on-site detection of relatively single gases.HT-M1
multiple gasesAlso known as a multi gas detector, one instrument can simultaneously detect multiple gasesHT-M4
(4) Determine the sampling method of the instrument
ClassificationdefinitionRecommended Model
diffusionThe instrument itself does not come with a pump and offers a wide range of gas options, making it suitable for open and well ventilated environmentsHT-M1/HT-M4
pump-suction typeThe instrument is equipped with an internal or external sampling pump, which can perform air extraction detection with fast response time, short detection time, and more accurate detection data. It is suitable for places with poor air circulation in closed environmentsHT-M1(B)/HT-M4(B)/HT-BH
(5) Fixed gas detectors are all single gas detectors. For fixed detectors, the configuration needs to be confirmed as follows:
definitionRecommended Model
without digital displayThe probe does not have a digital display functionHT-M5
with digital displayProbe with digital display functionHT-M5(s)
Equipped with sound and light alarm lightsThe alarm light is installed on the detector, and when the value is lower or higher than the set value, it can emit an audible and visual alarm function.
Equipped with alarm controllerCan connect multiple channel detection probes and centrally control multiple points. When the gas concentration reaches or exceeds the preset alarm value, the controller immediately emits an audible and visual alarm to remind early safety measures to be takenHT-B4
Product description
HT-M5 explosion-proof and explosion-proof fixed gas detection transmitter is a device that can detect oxygen, flammable gases, and toxic gases
Intelligent transmitters can be divided into display and non display types based on their display functions. The characteristics of this transmitter include
Performance and lower installation costs
Product Features
• The microprocessor technology
Explosion proof design, fast, reliable, and stable.
12-30V DC power supply
On site concentration display, sound and light alarm
The output signal can be customized by the user according to actual requirements.
1. Standard three wire 4-20mA analog signal output
2. Relay output (optional)
3. RS485 bus output (optional)
Fast response speed and high measurement accuracy
• Performance and lower installation costs
Low maintenance costs
Technical Specifications
Gas detection: Oxygen (O2) in the air
Range: 0-30% vol Range can be determined according to actual requirements
Accuracy:<± 5% (F.S)
Minimum reading: 0.1% Vol
Response time: ≤ 25 seconds
Sensor lifespan: 24 months
Sensor type: Electrochemical
Power supply: 12-30V DC power supply
Detection method: diffusion type
Working mode: Long term continuous work
Output signal: Standard three wire 4-20mA analog signal output; 2-wire output, relay output or RS485 output (optional)
Connection method: G1/2 male thread explosion-proof hose
Cable specification: Model RVVP3 × 1.0mm2
Signal transmission distance: ≥ 1000 meters
Structural material: die cast aluminum
Explosion proof mark: Exd II CT6
Protection level: IP65
Working temperature: -20~50 ℃ (depending on specific requirements)
Working humidity: ≤ 90% RH
Size/135 * 125 * 116mm without mounting bracket
167 * 145 * 126mm with bracket
Weight: less than or equal to 1KG without installation bracket
Supports are required for weights less than or equal to 1.4KG
Note: The above data depends on environmental conditions.
Our company produces various gas detection and monitoring instruments. If multiple or multiple gases need to be monitored simultaneously, HT-B4 series multi-point monitoring gas detection alarm controller can be equipped, which can centrally monitor 2-99 gases at the same time; It is recommended to choose a transmitter without concentration display on site for higher cost-effectiveness. Our company can provide you with gas monitoring design solutions and technical support. Welcome!