Welcome Customer !

Membership

Help

Hangzhou Double Color Intelligent Testing Instrument Co., Ltd
Custom manufacturer

Main Products:

mechb2b>Products

Hangzhou Double Color Intelligent Testing Instrument Co., Ltd

  • E-mail

    609778576@qq.com

  • Phone

    13588121213

  • Address

    4th Floor, Building 1, Fuhua Building, Zijin Science and Technology Innovation Park, Hangzhou, Zhejiang

Contact Now

HP250 fiber optic spectrometer

NegotiableUpdate on 05/23
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The HP-250 series fiber optic spectrometer adopts a high-speed Stm320 processor FreeRTOS system and a high-precision linear CCD optical sensor with 3648 image distance. It is developed and designed based on the principle of long focal cross asymmetric CT spectroscopy system, and has the characteristics of lightweight design, stable performance, high accuracy, high cost-effectiveness, and easy portability. It is also equipped with PC software

Product Details

The HP-250 series fiber optic spectrometer adopts a high-speed Stm320 processor FreeRTOS system and a high-precision linear CCD optical sensor with 3648 image distance. It is developed and designed based on the principle of long focal cross asymmetric CT spectroscopy system, and has the characteristics of lightweight design, stable performance, high accuracy, high cost-effectiveness, and easy portability. It is also equipped with PC software. The old-fashioned high-precision spectral analyzer is characterized by its large size, cumbersome operation, and high price. Sampling and measuring various types of spectral data energy, coupled with PC software, can efficiently analyze and process test data. It has measurement linearity and accuracy, and is widely used in colleges, experimental venues, homes, shopping malls, schools, factories, greenhouses, outdoor, on-site lighting measurement fields. It can also be used in the research and development of light source products, production line quality monitoring and other links. Some users have also received positive feedback in the eyewear and jewelry industries. Energy analysis can be performed on the transmittance, absorption, and reflectance of objects and liquids. Widely applicable in fields such as petrochemicals and basic organic chemicals, polymer chemicals, pharmaceuticals and clinical medicine, biochemistry, environmental science, textile industry, and food industry.



Partial industry applications:

1. LED detection and sorting 2. Printer color management 3. Neonatal jaundice detection 4. Water quality analysis

5. Crop quality analysis 6. Oil testing 7. Coated glass testing 8. Biochemical analysis

Environmental testing, air pollution, automobile exhaust testing 200-400nm

1、 Basic optical testing parameters

1. Correlation color temperature Tc (K), blackbody deviation Duv

2. Illuminance E (lx), Candlelight E (Fc), Radiant Illuminance Ee (W/m2)

3. Chromatic coordinates (x, y), (u, v), (u ', v')

4. Relative spectral power distribution P (λ)

5. Color rendering index Ra, Ri (i=1-15)

6. Color Tolerance SDCM (MacAdam Ellipses, Rectangular Boxes, and CIE u'v 'Circles)

7. Main wavelength, peak wavelength, center wavelength, centroid wavelength, half width

8. Light dark visual ratio S/P

9. Color purity, red ratio, green ratio, blue ratio, CIE1931 tricolor stimulus values X, Y, Z

10. Realism Rf, color gamut index Rg

11. More functional parameters can be customized

Spectral wavelength measurement

1. Basic model: 380-780 nm

2. Plant version: 350-800nm;

3. Flagship version: 350-950nm;

4. UV version: 200-400nm.

UVA 315-400nm

UVB 280-315nm

UVC 200-280nm

Wavelength accuracy ± 0.3nm

Test range: 0.1-200000 uW/cm2

Irradiance accuracy: ± 3%

5. Infrared version: 380-1050nm. (Special customization)

6. Blue light version: 380-780 nm

7. Strobe version: 380-780 nm

Test content

1. The basic testing items include commonly used parameters in the visible light range;

2. The Blu ray version adds:

Retinal blue light hazard weighted irradiance (mW/m2)

◆ Safety allowable irradiation time (S)

◆ Three parameters for hazard level;

3. The strobe version adds:

◆ Lamp flicker, flicker index, photometric change curve, flicker, fluctuation index (flicker index, FLICKER)

Measurement of percentage flicker, etc.

Intelligent light source flicker test

Real time observation of waveforms in the sub frequency range of flicker

◆ Simultaneously equipped with multiple tests such as spectrograms

◆ Complies with various international and domestic standards

◆ Rapid photometric change curve of light source

Flicker index, flicker percentage, flicker depth

4. The plant version adds:

Plant light source parameters (Eb, Ey, Er, Erb Ratio, PAR, PPFD, YPFD, Ep);

5. The flagship version adds:

TM-30 color parameters (fidelity Rf, color gamut index Rg)

◆ Plant light source parameters

◆ Strobe function

◆ Blue light function

6. The V UV version adds:

UV hazard irradiance (mW/m2)

◆ UVA irradiance (mW/m2)

◆ UVB irradiance (mW/m2)

◆ UVC irradiance (mW/m2)

3、 Product Features

1. Multiple optical inputs enter the slit directly or through optical fibers

2. Wavelength range: 200-1050nm optional

3. Spectral resolution: 0.2nm

4. Fiber coupler: SMA 905

5. Stray light:<0.1%

6. High speed data acquisition, integration time: millisecond level

7. Focal length 72.5mm symmetrical non crossing H-T optical path

8. Imported dazzling grating, CCD ultraviolet wavelength new anti ultraviolet coating

9. Install long pass filter or linear variable filter, software set wavelength range

10 Communication methods: USB communication, 485 communication protocol, 232 communication protocol, Bluetooth communication protocol

11. Dimensions: 80mm * 60mm * 40

4、 Communication Protocol (Example)