Welcome Customer !

Membership

Help

Shanghai Xijin Experimental Instrument Co., Ltd
Custom manufacturer

Main Products:

mechb2b>Products

Shanghai Xijin Experimental Instrument Co., Ltd

  • E-mail

    2388884494@qq.com

  • Phone

    13774484521

  • Address

    No. 782 Yongyue Road, Pujiang Town, Minhang District, Shanghai

Contact Now

Gypsum phase composition analyzer

NegotiableUpdate on 01/22
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

At present, the commonly used method for gypsum phase composition analyzer is the drying weight loss method. Based on the quality difference before and after drying, the anhydrous, hemihydrate, and dihydrate values of gypsum are calculated to determine its grade. But this method has a very long testing process and requires manual weighing and calculation throughout the entire process, which is prone to human error.

Product Details

currentlyGypsum phase composition analyzerThe commonly used method is the drying weight loss method, which calculates the anhydrous, hemihydrate, and dihydrate values of gypsum based on the quality difference before and after drying to determine the grade of gypsum. But this method has a very long testing process and requires manual weighing and calculation throughout the entire process, which is prone to human error.

Gypsum phase composition analyzer

The gypsum phase composition analyzer is based on the principle of the national standard drying method, and achieves fully automatic and rapid analysis of gypsum phase composition through its built-in high-precision weighing device and fast and uniform drying device. Compared with the drying method, it has the following advantages:

Instrument principle

Thermogravimetric analysis method

occupied space

About 0.25 square meters

measure time

Within 3 hours (usually around 2.5 hours)

test environment

No special requirements

test process

fully automatic

data recording

Comes with built-in storage and can also be connected to computer storage

advantage

  • ·Good temperature control, all aluminum base, four layer insulation measures for the sensor, and thermal circulation convection mode design greatly reduce the temperature drift of the sensor and improve the measurement accuracy and repeatability of the instrument
  • ·The sample is uniformly heated
  • ·Fully automated testing, easy to operate
  • ·goodHeating/cooling performance
  • ·Quick measurement
  • ·Can conduct large-scale sample analysis
  • ·The instrument occupies very little space

meet the standard

GB/T36141-2018 Analysis Method for Phase Composition of Building Gypsum GB/T17669.2-1999 Determination of Crystalline Water Content of Building Gypsum GB/T29249-2012 Electronic Weighing Drying Method Moisture Determination Instrument GB/T5484-2000 Gypsum Chemical Analysis Method

F-HZ-DZ-FJSK-0101 Determination of Crystalline Water of Non metallic Minerals (Gypsum) - Mass Method

measure time

The total duration of the three-phase process is about 2.5H (800-1000 seconds for one step without water phase/with attached water)

Detection Mode

test mode

(Moisture, three-phase, purity, crystal water)

Multifunctional integrated machine

Measurement indicators include: three-phase content, attached water/crystal water, gypsum grade, moisture content/solid content

Three phase measurement results

Adsorbed water, anhydrous gypsum AIII, hydration increment, hemihydrate gypsum HH, dehydration amount, dihydrate gypsum DH

load cell

Imported sensors

Heating light source

Specially designed circular heating light source

heating program

fast

countdown function

Automatic timing, intelligent start measurement

data storage

The instrument comes with storage function, allowing access to nearly 50 sets of measurement data without the need to connect to a computer

Display curve

Simultaneously display three test curves (including moisture M, weight W, temperature T)

Sample disk size

Diameter 100 (mm)

screen

4.3-inch high-definition high-resolution touch capacitive screen, interactive menu design, convenient for customers to use

communication interface

1. Standard RS232 2. USB interface data export

Weighing range

0-100g

Weighing accuracy value

0.001g

Data accuracy value

0.01%

temperature range

Starting at -240 ℃

Data measurement range

0-100%

Printing interface

Wireless Bluetooth signal output

optional

Scalable wireless cloud storage function