GPC gel chromatograph (GPC gel chromatograph workstation) has two remarkable features:
Feature 1:
1. Allow users to freely design formulas or write macro programs based on various statistical molecular weights and molecular weight distribution width indices calculated to complete additional calculations.
2. Compatible with N2000 chromatography data workstation.
Feature 2:
GPC provides three correction methods - peak position method, universal method, and trial and error method;
2. Molecular weight methods: unimodal calculation method, interval calculation method;
3. Molecular weight determination is based on the molecular weight calibration curve and peak slice area calculation of polymer substances, which can be used in conjunction with various types of chromatographs;

High performance liquid chromatography HPLC detection scheme for doxycycline hydrochloride
-Sample processing procedure-
Accurately weigh an appropriate amount of doxycycline hydrochloride reference substance, add an appropriate amount of 0.01mol/L hydrochloric acid solution, dissolve by ultrasound, and dilute with 0.01mol/L hydrochloric acid solution to a solution containing approximately 1mg doxycycline hydrochloride per 1ml. Shake well, filter through a 0.45 µ m organic system filter membrane, accurately measure 20 µ L, inject into a liquid chromatograph, and record the chromatogram.
-Chromatographic conditions-
Chromatographic column: C18, 4.6 mm*250 mm, Particle size 5 µ m
Mobile phase: Acetonitrile: Acetate buffer solution=25:75
Wavelength: 280nm
Flow rate: 1.0mL/min
GPC gel chromatographto configure:
Please click to view the image details
|
LC-10Tvp high-pressure constant current infusion pumpIt is a multifunctional constant current infusion pump with high flow accuracy, corrosion resistance, and high pressure resistance...... |
|
SPD-10Tvp UV detectorA dual beam monochromatic system composed of imported deuterium lamps, photovoltaic cells, and 1200/mm concave gratings...... |
|
8725i injection valveIt is a six way valve in which the sample is loaded through an embedded needle track in front of the valve...... |
|
Vertex C18 ColumnFeaturing high surface coverage and complete tail sealing, it is suitable for chromatographic analysis in a wide range of pH values from 1.5 to 10.0...... |
|
AP-01P oil-free vacuum pumpIt is a small vacuum pump with a lightweight and beautiful appearance, high efficiency, low noise, and adjustable pressure...... |
|
VI2010 Chromatography WorkstationBreaking through the bottleneck of current domestic chromatography software only having serial port communication, truly realizing USB interface communication...... |
Calibration of standard samples:
The software can calibrate any number of standard samples. Multiple parallel injections of the same sample to eliminate errors.
Several correction calculation methods: peak position method, universal method, trial and error method, and internal standard peak correction method.
The calibration curve can be fitted using linear equations, quadratic and cubic polynomial equations, and the least squares method.
Automatically calculate the standard deviation and correlation coefficient.
You can output a calibration curve graph in the report.
Molecular weight determination:
Two methods for calculating molecular weight: unimodal calculation method and interval calculation method
You can set up a slicing method to calculate the corresponding molecular weight for any segment in the spectrum and automatically deduct the baseline. The following molecular weights can be obtained and a molecular weight distribution map can be created:

Hardware requirements:
CPU Pentium 133 or above
Memory above 64MB
Hard drive with more than 1GB of space except for the system
CD drive installation software is required
At least one RS232 serial port
Monitor with 800 * 600 * 256 colors or more
Keyboard and mouse must
GPC gel chromatography workstation consists of general chromatography workstation software and special module for molecular weight calculation. The general chromatography workstation software is responsible for the collection and processing of spectra (i.e. detecting peaks in the spectrum and establishing appropriate baselines for the detected peaks), while the molecular weight calculation module is responsible for calculating molecular weight based on a pre fitted calibration curve (the relationship curve between molecular weight and peak time).