GL II type radiatorIt uses steel aluminum composite finned tubes or steel wound finned tubes as heat exchange elements, mostly double circuit (two rows) or multi circuit (four rows) air heat exchangers, which can avoid stress concentration caused by thermal expansion and other reasons; ResistanceHigh temperature and corrosion resistance. Widely used for air heating in dehumidification, drying, heating and ventilation systems, or air cooling in cooling air conditioning systems.

1GLⅡtyperadiatoroverview
1. The GL II radiator is a steel double circuit (two rows) or multi circuit (four rows, six rows) structure. The heat dissipation pipes are made of seamless steel pipes with a diameter of 25 * 2mm, which are twisted into 15 * 0.3mm corrugated steel strips by a special machine in a spiral shape with a spacing of 4.5mm. It has high pressure resistance and corrosion resistance;

2. GL II type radiator is a standard model radiator, consisting of a steel frame and heat dissipation pipes, manufactured and produced according to the national standard atlas;

3.GL II typeradiatorThe heat dissipation pipes are connected by U-shaped elbows and supported by porous plates, which can eliminate stress caused by thermal expansion and other reasons. They have high temperature resistance, good corrosion resistance, and durability;

GL II type radiators are widely used for air heating in drying systems, as well as for large and medium-sized heating and ventilation systems, or for air cooling in cooling air conditioning systems;

5. Working medium of GL II radiator: steam, high-temperature water, heat transfer oil, low-temperature saltwater, etc;

6.GL II typeradiatorWorking pressure: 1.0MPa, 1.6MPa, 2.5MPa, 4.0MPa

7. GL II type radiator numbering method:
Model - Row Number - Surface Tube Number - Surface Tube Length (inches)
If four rows of pipes are used, with a surface pipe count of 10 and a pipe length of 42 inches, then it is GLII-4-10-42



GLII type radiatorParameter table:

surface
Number of pipes
B(mm)
Surface tube length
24 30 36 42 48 54 60 66 72 78 84 90 96 102 108 114 120
A(mm)
Row number
700 850 1000 1150 1300 1450 1600 1750 1900 2050 2200 2350 2500 2650 2800 2950 3100
Basic parameters
6
318
Heat dissipation area (m)2
Heat dissipation area (m)2
Wind affected area (m)2
Ventilation net cross-sectional area (m)2
Inlet and outlet pipe joint (inch)
Net weight (kg)
Net weight (kg)
2
4
2 or 4
2 or 4
2 or 4
2
4
4.7
9.4
0.157
0.083
1
19
34
5.84
11.68
0.196
0.108
1
22
40
6.98
13.96
0.235
0.126
1
25
45
8.12
16.24
0.273
0.145
1
28
50
8
396
Heat dissipation area (m)2
Heat dissipation area (m)2
Wind affected area (m)2
Ventilation net cross-sectional area (m)2
Inlet and outlet pipe joint (inch)
Net weight (kg)
Net weight (kg)
2
4
2 or 4
2 or 4
2 or 4
2
4
6.26
12.52
0.205
0.108
1
23
42
7.78
15.56
0.255
0.135
1
27
50
9.32
18.64
0.306
0.162
1
31
58
10.84
21.68
0.356
0.189
1
35
66
12.42
24.84
0.406
0.215
1
39
74
13.04
27.88
0.457
0.242
1
43
82
15.48
30.96
0.507
0.268
2
47
90
10
474
Heat dissipation area (m)2
Heat dissipation area (m)2
Wind affected area (m)2
Ventilation net cross-sectional area (m)2
Inlet and outlet pipe joint (inch)
Net weight (kg)
Net weight (kg)
2
4
2 or 4
2 or 4
2 or 4
2
4
7.82
15.64
0.253
0.134
1
28
50
9.72
19.44
0.315
0.167
1
33
59
11.64
23.28
0.377
0.2
1
37
66
13.56
27.12
0.438
0.233
1
41
73
15.48
30.96
0.501
0.266
1
45
81
17.42
34.84
0.563
0.298
1
50
90
19.34
38.63
0.625
0.332
1
55
99
21.22
42.44
0.687
0.366
1
60
109
23.18
46.36
0.749
0.398
1
66
119
25.08
50.16
0.812
0.43
1
72
129
27
54
0.873
0.463
1
78
140
12
552
Heat dissipation area (m)2
Heat dissipation area (m)2
Wind affected area (m)2
Ventilation net cross-sectional area (m)2
Inlet and outlet pipe joint (inch)
Net weight (kg)
Net weight (kg)
2
4
2 or 4
2 or 4
2 or 4
2
4
9.36
18.72
0.3
0.159
2
37
66
11.66
23.32
0.374
0.198
2
43
78
13.98
27.96
0.447
0.237
2
49
90
16.26
32.52
0.521
0.276
2
55
102
18.62
37.24
0.595
0.316
2
61
114
20.9
41.8
0.669
0.354
2
67
126
23.2
46.4
0.741
0.393
2
73
139
25.46
50.92
0.816
0.433
2
79
150
27.8
55.6
0.891
0.473
2
85
162
30.1
60.2
0.965
0.512
2
91
174
32.38
64.76
1.035
0.549
2
97
186
34.7
69.4
1.11
0.588
2
103
198
37
74
1.185
0.628
2
109
210
39.34
78.68
1.258
0.666
2
115
222
41.7
83.4
1.335
0.707
2
121
234
44
88
1.41
0.748
2
127
246
46.2
92.4
1.48
0.784
2
133
258
15
669
Heat dissipation area (m)2
Heat dissipation area (m)2
Wind affected area (m)2
Ventilation net cross-sectional area (m)2
Inlet and outlet pipe joint (inch)
Net weight (kg)
Net weight (kg)
2
4
2 or 4
2 or 4
2 or 4
2
4
11.62
23.24
0.372
0.197
2
46
83
14.58
28.16
0.463
0.245
2
53
95
17.48
34.96
0.554
0.294
2
60
108
20.34
40.68
0.645
0.342
2
68
122
23.24
46.48
0.737
0.391
2
75
135
26.12
52.24
0.828
0.438
2
82
148
29
58
0.92
0.488
2
89
161
31.82
63.64
1.01
0.536
2
96
174
34.78
69.56
1.101
0.584
2
103
187
37.62
75.24
1.192
0.632
2
111
200
40.5
81
1.285
0.681
2
118
213
43.4
86.8
1.375
0.73
2
125
226
46.2
92.4
1.468
0.777
2
132
239
49.2
98.4
1.56
0.826
2
139
252
52.1
104.2
1.65
0.875
2
146
265
55
110
1.74
0.923
2
153
278
57.8
115.6
1.835
0.973
2
160
291
18
786
Heat dissipation area (m)2
Heat dissipation area (m)2
Wind affected area (m)2
Ventilation net cross-sectional area (m)2
Inlet and outlet pipe joint (inch)
Net weight (kg)
Net weight (kg)
2
4
2 or 4
2 or 4
2 or 4
2
4
14.06
28.12
0.443
0.235
2
53
92
17.5
35
0.552
0.293
2
67
108
20.94
41.88
0.66
0.35
2
69
124
24.4
48.8
0.769
0.407
2
77
140
27.88
55.76
0.879
0.464
2
85
156
31.38
62.76
0.987
0.523
2
92
172
34.8
69.6
1.095
0.58
2
100
198
38.22
76.44
1.204
0.638
2
108
204
41.7
83.4
1.313
0.693
2
116
220
45.1
90.2
1.42
0.753
2
124
236
48.6
97.2
1.53
0.811
2
132
252
52.08
104.16
1.64
0.869
2
140
268
55.5
111
1.75
0.928
2
146
284
59
118
1.86
0.986
2
156
300
62.5
125
1.956
1.035
2
164
306
65.9
131.8
2.08
1.102
2
172
332
69.4
138.8
2.185
1.158
2
180
348
21
908
Heat dissipation area (m)2
Heat dissipation area (m)2
Wind affected area (m)2
Ventilation net cross-sectional area (m)2
Inlet and outlet pipe joint (inch)
Net weight (kg)
Net weight (kg)
2
4
2 or 4
2 or 4
2 or 4
2
4
16.3
32.6
0.515
0.276
2
60
105
20.4
40.8
0.641
0.342
2
96
123
24.44
48.88
0.767
0.407
2
78
28.42
56.84
0.893
0.473
2
87
32.34
64.68
1.02
0.541
2
96
177
36.58
73.16
1.145
0.607
2
103
195
40.6
81.2
1.272
0.674
2
112
213
44.6
89.2
1.399
0.741
2
121
231
48.7
97.4
1.528
0.81
2
130
249
52.7
105.4
1.651
0.875
2
139
267
56.7
113.4
1.78
0.944
2
148
285
60.8
121.6
1.905
1.01
2
157
303
64.7
129.4
2.03
1.075
2
166
321
68.8
137.6
2.16
1.145
2
175
339
72.9
145.8
2.28
1.208
2
184
357
76.9
153.8
2.41
1.28
2
193
375
80.8
161.6
2.54
1.345
2
202
393
24
1027
Heat dissipation area (m)2
Heat dissipation area (m)2
Wind affected area (m)2
Ventilation net cross-sectional area (m)2
Inlet and outlet pipe joint (inch)
Net weight (kg)
Net weight (kg)
2
4
2 or 4
2 or 4
2 or 4
2
4
18.62
37.24
0.587
0.313
2
68
120
23.26
46.52
0.73
0.388
2
79
141
27.9
55.8
0.873
0.463
2
90
162
32.54
65.08
1.016
0.538
2
101
182
37.9
75.8
1.161
0.615
2
112
201
41.8
83.6
1.307
0.693
2
122
220
46.4
92.8
1.451
0.769
2
133
239
50.92
101.84
1.591
0.843
2
144
258
55.6
111.2
1.739
0.921
2
155
277
60.2
120.4
1.881
0.998
2
164
295
64.8
129.6
2.025
1.075
2
174
314
69.4
138.8
2.17
1.15
2
184
333
73.9
147.8
2.315
1.225
2
194
352
78.7
157.4
2.455
1.3
2
204
371
83.4
166.8
2.605
1.38
2
215
390
89.8
179.6
2.745
1.455
2
226
410
92.4
184.8
2.89
1.53
2
238
430

Wuxi Delida Heat Exchanger is a professional manufacturer of finned tubes and air heat exchangers. Welcome to consult and negotiate!