Product Features
- High precision, system error less than2%
- Modular design, easy to integrate, maintain, and upgrade
- Multiple total exhaust flow range products are available, suitable for engines of different displacements
- Reliable performance, meeting the requirements of China VI B phase and international emission regulations
meet the standard
National Standard
GB 18352.6-2016 Limits and Measurement Methods for Pollutant Emissions from Light duty Vehicles (Six Stages)
GB 17691-2018 Limits and Measurement Methods for Pollutant Emissions from Heavy duty Diesel Vehicles (Six Stages)
GB 20891-2014 Limits and Measurement Methods for Exhaust Pollutants from Diesel Engines for Non Road Mobile Machinery (Stage III and IV)
HJ 1014-2020 Technical Requirements for Pollutant Emission Control of Non Road Diesel Mobile Machinery
GB 14622-2016 Motorcycle Pollutant Emission Limits and Measurement Methods (Four Stage)
International Standard
Regulation (EC) No 715/2007
Regulation (EC) No 595/2009
Regulation (EU) No 168/2013
Regulation (EU) 2016/1628
US EPA Tier 3
US EPA 40 CFR Part 86,1039,1054
Technical Specifications
| Gasboard-9802 Key performance parameters |
| Dilution method | Constant volume sampling, critical flow Venturi tube(CFV) |
| Diluted exhaust flow rate | 15m³/min,30m³/min,60m³/min,90m³/min,120m³/minoptional |
| System accuracy | < ±2%F.S.(Propane injection inspection) |
| Sampling measurement | Sampling critical flow Venturi tube(3 L/min,6 L/minEach one),Can be configured according to actual needs |
| Sampling airbag | 2*3or2*4 |
| working power supply | 380/220VAC50Hz |
| contact method | RS-232/485/TCP |
*Please refer to the specifications for specific parameters. For more technical information, please contact: or