Double person nucleic acid sampling booth Product Concept
The nucleic acid sampling booth is a product designed specifically for sampling work. The equipment sends clean and safe air into the internal space through the configured ventilation and purification system, and maintains a relatively positive pressure inside. By constructing an isolated positive pressure space, the air inside the cabin is isolated from the outside, preventing external air from entering the cabin and effectively protecting the safety of internal medical staff from infection due to sampling work. While ensuring safety, it improves the operational flexibility and comfort of medical staff, saves testing time, and enhances testing efficiency.
2. work environment
(1)temperature: -10-40℃
(2)relative humidity: 45-60%RH
(3)voltage: 220Vscholar22V, 50Hzscholar1 Hz
(4)power:2000W
3. Structural characteristics
(1)The main body adopts assembled panel house structure, and the transportation, installation and use of finished products can be flexibly formulated according to needs to adapt to various sites;
(2)Equipped with high-efficiency filters, it can provide a positive pressure environment with a cleanliness level of 10000, effectively isolating medical staff and ensuring their safety;
(3)The front window glass is equipped with long rubber gloves and a dialogue system, making sampling convenient and fast, without the need for direct contact with the sampled personnel throughout the entire process;
(4)Avoiding the feeling of confinement and discomfort caused by wearing clothing, effectively reducing work intensity while saving protective equipment;
(5)Built in wall mounted air conditioning provides a good working environment for medical staff:
(6)Can accommodate multiple staff members working simultaneously, facilitating collaboration to complete tasks;
(7)Suitable for outdoor installation and use, or other scenarios that require protection.
Double person nucleic acid sampling boothProduct Technical Parameters
product name:Nucleic acid sampling booth
Dimensions:(wide*deep*tall)2200mm×1500mm×2600mm;
Internal dimensions:(wide*deep*tall)2000mm×1300mm×2040mm
filter:regarding0.3μmThe particle filtration efficiency can reach99.995%
noise level:≤75dB(A)
rated power:2KW
Maximum air supply volume:600m³/h
Average illuminance:≥300lx
Lighting power:8W*1(LEDlight)
UV disinfection equipment:20W*1(UV lamp)
Clean transfer window:outside diameter400mm*400mm*400mm
walkie-talkie:host+Auxiliary engine
air-conditioning:A cold and warm air conditioner
fan:centrifugal fan
weight:gross weight450KG(Excluding internal personnel)
use:twopeople
5. Structural composition
5.1 Structure of nucleic acid sampling booth
1Fan, high-efficiency filter2Lighting fixtures3Air conditioning4UV disinfection lamp5Window intercom6Rubber gloves7Power switch, socket8、Storage rack9Caster wheels 10Stainless steel garbage bin
5.2 Ventilation and purification system
The ventilation and purification system is a system that ensures the performance of this equipment. It consists of a fan and a high-efficiency filter. The main function of a ventilation and purification system is to deliver clean and safe air into the internal space and maintain a relatively positive pressure inside.
5.3 UV disinfection lamp tube
The ultraviolet disinfection lamp is located inside the operation area to ensure that ultraviolet light can fully irradiate all spaces in the operation area for thorough disinfection.
5.4 light
Ensure that the average illumination level within the operating area meets the standard requirements.
5.5 Window intercom
The window intercom is located inside the operation area and at the window to ensure normal communication between medical staff and external personnel of the equipment.
5.6 Air conditioning equipment
Ensure the temperature of medical personnel during internal operations and provide a comfortable working environment for operators.