-
E-mail
13310000820@163.com
-
Phone
13310000820
-
Address
Room 1108, Building 6, Lane 158, Baoxiang Road, Jiading District, Shanghai
Shanghai Huibin Instrument Co., Ltd
13310000820@163.com
13310000820
Room 1108, Building 6, Lane 158, Baoxiang Road, Jiading District, Shanghai

Detu safeguards public safety, FeverDetection VS*



Mainly applicable to:
Domestic airport passenger entrances and exits, dock cruise passengers entering and exiting, driver temperature at domestic intersections, port and shore entrances/bus passages, hospital reception halls, rapid screening of temperature for large factory employees, disease prevention for primary and secondary school students, as well as densely populated shopping malls and office buildings.
Detu testo890 human body temperature screening infrared thermal imager
Testo FeverDetection Assistant
Detu infrared thermal imaging instrument testo 885/890Use brand newTesto FeverDetectionAssistant, used for measuring potential viruses and suspected carriers of cases:
Detu testo890 human body temperature screening infrared thermal imager
Q1: What is the difference between an infrared thermal imager and an infrared thermometer?
De Tu:Infrared thermometer measures the average temperature of a circular area with the measured point as the radius. This type of product needs to consider the distance coefficient ratio of the product, so the measurement distance is short and the accuracy is related to the measurement distance, making it impossible to measure the temperature surface of the measured object over a large area. Commonly used for rapid detection of individual body temperature, the well-known thermometer is an infrared thermometer.
The working principle of an infrared thermal imager is that "any object above zero emits infrared radiation". Therefore, the detector of an infrared thermal imager can passively receive the infrared radiation of the object being measured, convert it into temperature values, and visually display the temperature distribution of the object being measured. itIt has the characteristics of non-contact measurement, temperature visualization, and large-area measurement, and is not harmful to the human body. This also means that using infrared thermal imagers for temperature screening can achieve greater safety, efficiency, and minimize missed detections.
Q2: How to avoid false positives during temperature screening?
De Tu:In daily life, we often have the experience that sometimes our body temperature is over 37 ° C or only below 36 ° C, but we feel quite healthy and there is no discomfort. So, what criteria does the thermal imager use to determine if there is a temperature difference during temperature screening? How can we avoid false positives? In fact, the normal body temperature of a person does fluctuate. When stimulated by the temperature of the internal and external environment, the body automatically adjusts its temperature to achieve a new body heat balance and adapt to the environment. The key to reducing false positives and false negatives caused by normal temperature regulation lies not in the measured temperature, but in identifying abnormal alarm temperatures. This alarm temperature should be a floating value.
Most thermal imaging devices currently available on the market require prior input of a temperature alarm value (i.e. average human body temperature). If the temperature exceeds this alarm value, the thermal imaging camera will sound an alarm. Entering a fixed value may cause errors and false positives.The epidemic prevention detection function of the Detu thermal imager automatically adjusts the temperature alarm value through a special algorithm, identifies "potential patients" with abnormal body temperature exceeding the crowd, and immediately alarms.
Q3: Is there an alarm prompt when the thermal imager detects abnormal body temperature?
De Tu:The Detu testo 885/890 infrared thermal imager has an alarm function, which can set dual sound/color alarm prompts to avoid omissions caused by personnel fatigue or unclear prompts.
Q4: What is the difference between a thermal imager with epidemic prevention detection function and other thermal imagers?
De Tu:The body surface temperature varies with different body parts, and the accuracy of temperature screening is also affected by which part of the body is measured. Generally speaking, the temperature at the eye socket is close to the core temperature of the human body, which is particularly suitable for representing the true body temperature of the human body. So, in addition to the special algorithm for automatically adjusting the alarm temperature value mentioned above,The thermal imager with epidemic prevention detection function has a facial recognition algorithm that automatically measures the temperature at the eye socket of the human body, and detects each subject in the crowd one by one, guiding users to quickly complete accurate temperature screening.Detu provides a thermal imaging camera for epidemic prevention testing and recommends that you remove your glasses when quickly detecting eye socket temperature, as glasses can block infrared radiation.
Q5: Why choose a thermal imager with screen mirroring function?
De Tu:The projection function of the thermal imager can output the images generated on the screen of the thermal imager to other display devices,By utilizing the non-contact measurement features of projection screens and thermal imagers, it is possible to ensure a safe distance between the testing personnel and the subject being tested, and prevent cross interference.The Detu testo 885/890 thermal imager has a projection function and uses an HDMI cable. It is suitable for most display devices and does not require any adapters.
Q6: How to choose portable, fixed, or semi fixed thermal imagers?
De Tu:Portable refers to direct handheld operation, suitable for inspection; Fixed type refers to the need to connect to a computer to display measurement images and control operations, suitable for long-term fixed-point detection; Semi fixed refers to the use of the Detu thermal imager even when there is insufficient or damaged online equipment, which is easy to fix and does not require special installation.
Q7: Do you have the DeTu infrared thermal imager in stock?
De Tu:The testo 882 infrared thermal imager is available in stock. Due to the special period of the epidemic, customers can confirm their orders through email first, and then complete the payment process such as the contract. The testo 885/890 thermal imaging camera with epidemic prevention detection function has been transferred from Germany and will soon be available for ordering.
Detu testo890 human body temperature screening infrared thermal imager
Infrared resolution of 640 × 480 pixels; After adopting SuperResolution infrared superpixel technology, it can be increased to 1280 × 960 pixels; Thermal sensitivity<40 mK
Four types of lenses are available to meet different measurement needs: standard lens (25 ° x 19 °), wide-angle lens (42 ° x 32 °), telephoto lens (15 ° x 11 °), and telephoto lens (6.6 ° x 5 °)
The instrument can be equipped with SQA intelligent sequence shooting module, surface humidity imaging function, QR code address automatic archiving function, panoramic image stitching function, JPEG storage and other practical functions
This product integrates a visible light digital camera and has more display performance; The delivery includes instrument box, storage card, professional software, etc
The testo 890 is a professional high-performance infrared thermal imager that can be equipped with four types of lenses to meet different measurement distances and requirements. Suitable for industrial and building diagnostics, such as voltage system inspection, high temperature measurement, circuit board heat dissipation analysis, solar power plant maintenance, and building thermal imaging for energy efficiency evaluation.
The product includes
The testo 890 infrared thermal imager is equipped with an infrared superpixel module
| lens | standard lens | wide-angle lens | telephoto lens | Ultra long focal lens | |
| Field of View (FOV) | 25° x 19° | 42° x 32° | 15° x 11° | 6.6° x 5° | |
| Small focusing distance | 0.2 m | 0.1 m | 0.5 m | 2.0 m | |
| Spatial Resolution (IFOV) | 0.68 mrad | 1.13 mrad | 0.42 mrad | 0.18 mrad | |
| Spatial Resolution (IFOV) Enable Super infrared superpixel |
1280 x 960 pixels/0.43 mrad | 1280 x 960 pixels/0.71 mrad | 1280 x 960 pixels/0.26 mrad | 1280 x 960 pixels/0.11 mrad | |
| Infrared image output | |
|---|---|
focus |
Automatic |
infrared resolution |
640 x 480 pixels |
Image refresh frequency |
33 Hz* |
Infrared superpixel (spatial resolution) |
0.71 mrad (Standard lens), 0.43 mrad (25° lens), 0.26 mrad (Telephoto lens), 0.11 mrad (Supertele) |
Infrared superpixel (pixel) |
1280 x 960 pixels |
Geometric Resolution (IFOV) |
1.13 mrad (standard lens) |
Small focusing distance |
0.1 m (standard lens) |
field of view |
42° x 32° (Standard lens), 25° x 19° (25° lens), 15° x 11° (Telephoto lens), 6.6° x 5° (Supertele) |
thermal sensitivity |
<40 mK at 30 ° C |
spectral range |
7.5 ~ 14 µm |
*inside the EU, outside 9 Hz
| Visible light image output | |
|---|---|
Small focusing distance |
0.5 m |
image pixel |
3.1 MP |
| image display | |
|---|---|
Display screen options |
Infrared image/visible light image |
color |
9 types |
panel type |
10.9 cm (4.3 ') LCD touch screen 480 x 272 pixels |
digital zoom |
1-; 3-fold |
video output |
USB 2.0, Micro HDMI |
| measurement | |
|---|---|
Reflection temperature |
manual |
Transmission correction |
✓ |
measurement range |
-30~+100 ° C; 0~+350 ° C (optional); 0~+650 ° C (optional) |
high temperature measurement |
+350 . .. +1200 °C (not in connection with the telephoto lens) |
precision |
± 2 ° C or ± 2% measurement value |
emissivity |
0.01; one |
Zui High Temperature Accuracy |
± 2 ° C or ± 2% measurement value |
| Measurement function | |
|---|---|
Surface humidity imaging |
✓ |
Humidity measurement |
Depends on the cloud service certificate level |
Solar mode |
✓ |
Analysis function |
10 measurement and analysis points, automatic tracking of hot and cold spots, 5 temperature box selection areas (highest, lowest, and average temperature), isothermal function, alarm function |
Humidity measuring instrument with humidity measurement |
with radio humidity probe; (automatic measurement value transfer in real time); *Wireless humidity probes only in the EU, Norway, Switzerland, USA, Canada, Colombia, Turkey, Brazil, Chile, Mexico, New Zealand, Indonesia |
| Image equipment | |
|---|---|
digital camera |
✓ |
Process analysis package |
Depends on the cloud service certificate level |
JPEG storage |
include |
video stream |
via HDMI |
Video measurement |
Three measurement points |
Sound recording |
Bluetooth earphones/wired earphones |
laser |
laser marking |
Panoramic image assistance |
✓ |
Power-LED |
✓ |
standard lens |
42° x 32° |
interchangeable lens |
25° x 19°; 15° x 11°; 6.6° x 5° |
Measurement address recognition |
✓ |
interface |
Labview; Free website download; USB |
Fever detection |
Depends on the cloud service certificate level |
**** Bluetooth only in the EU, Norway, Switzerland, USA, Canada, Colombia, Turkey, Japan, Russia, Ukraine, India, Australia
| image storage | |
|---|---|
image format |
.bmt; Can be saved as. bmp; .jpg; .png; .csv; .xls |
Video file format |
.wmv; .mpeg-1; Detu proprietary format (full infrared video) |
storage device |
SD cart 2GB (approx. 1500 - 2000 images) |
| power supply | |
|---|---|
Battery Type |
fast charger |
Operating Time |
4.5 hours |
charging options |
Charger (optional) |
AC power supply |
yes |
| environmental situation | |
|---|---|
Shell protection level |
IP54 |
vibration |
2G |
ambient humidity |
20 to 80 % RH non-condensing |
Storage temperature |
-30 ~ +60 °C |
Operating temperature |
-15 ~ +50 °C |
| Physical specifications | |
|---|---|
Tripod interface |
1/4' - 20UNC |
shell |
ABS |
weight |
1,630 g 1630 g |
size |
253 x 132 x 111 mm |
| PC software | |
|---|---|
system requirements |
Windows 10; Windows Vista; Windows 7 (Service Pack 1); Windows 8; interface: USB 2.0 |
| Infrared thermal imager standard/warranty | |
|---|---|
EU -/EG Regulation |
2004/108/EG |
Infrared resolution of 640 × 480 pixels; After adopting SuperResolution infrared superpixel technology, it can be increased to 1280 × 960 pixels; Thermal sensitivity<40 mK
Four types of lenses are available to meet different measurement needs: standard lens (25 ° x 19 °), wide-angle lens (42 ° x 32 °), telephoto lens (15 ° x 11 °), and telephoto lens (6.6 ° x 5 °)
The instrument can be equipped with SQA intelligent sequence shooting module, surface humidity imaging function, QR code address automatic archiving function, panoramic image stitching function, JPEG storage and other practical functions
This product integrates a visible light digital camera and has more display performance; The delivery includes instrument box, storage card, professional software, etc
The testo 890 is a professional high-performance infrared thermal imager that can be equipped with four types of lenses to meet different measurement distances and requirements. Suitable for industrial and building diagnostics, such as voltage system inspection, high temperature measurement, circuit board heat dissipation analysis, solar power plant maintenance, and building thermal imaging for energy efficiency evaluation.