Welcome Customer !

Membership

Help

Shenzhen Taiqin Technology Co., Ltd
Custom manufacturer

Main Products:

mechb2b>Products

Shenzhen Taiqin Technology Co., Ltd

  • E-mail

    fanhh@sztaiqin.com

  • Phone

    13823754565

  • Address

    8012, Building 1, Xinzhongtai Technology Industrial Park, Donghuan 1st Road, Longhua New District, Shenzhen

Contact Now

Daily power analyzer

NegotiableUpdate on 01/22
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The daily power analyzer PW3390 $r $n for measuring the power conversion efficiency of motors and frequency converters achieves high-level power basic accuracy; #177; 0.04%rdg. #177; 0.05% f.s $r $n ● 200kHz measurement frequency band, with stable amplitude and phase accuracy at high frequencies $r $n ● Achieving miniaturization/lightweight of the body, meeting the high-precision measurement of $r $n ● 50ms in the field and research laboratory, as well as parallel operation of harmonic analysis, transient waveform, interference analysis, efficiency loss and all other projects

Product Details

Daily power analyzerPW3390

Measuring the power conversion efficiency of motors and frequency convertersDaily power analyzerPW3390

● Achieve high-level power basic accuracy of ± 0.04% rdg. ± 0.05% fs
A measurement frequency band of 200kHz, with stable amplitude and phase accuracy at high frequencies
● Achieve miniaturization/lightweighting of the body to meet high-precision measurements on site and in research laboratories
50ms high-precision and high-speed calculation of transient power, while parallel calculation of harmonic analysis, transient waveform, interference analysis, efficiency loss, and all other projects
Multiple systems can simultaneously measure and collect data from up to 8 synchronized devices
● Use clamp current sensors for simple power measurement
Measurement of Current and Power Balance for the New Fuel Efficiency Standard WLTP

specific model
PW3390-01
PW3390-02 (D/A output)
PW3390-03 (D/A output, motor analysis)

The PW3390 host cannot be measured separately. Please purchase additional voltage wires and current sensors from the options according to the measurement purpose.
Motor analysis and D/A output cannot be added later, please note.

Effect of fuel consumption performance evaluation test on vehicles

This product has the power measurement performance required for fuel consumption measurement according to the new fuel consumption standard "WLTP mode" fuel consumption test, as well as the function of facilitating test implementation. Please review the experimental video.

Performance evaluation test of new fuel efficiency standard WLTP mode

When measuring fuel efficiency according to the WLTP standard, it is required to accurately measure the current accumulation and power accumulation of the charging and discharging of various batteries in the system. The high-precision clamp current sensor and PW3390's high DC accuracy, as well as the 50ms interval current accumulation and power accumulation functions, effectively evaluate the fuel efficiency performance of the vehicle.

Current sensor suitable for vehicle measurement

The high-precision sensor with clamp design can be quickly wired without cutting the wires. The temperature range for use is -40 ℃ to 85 ℃. It has excellent temperature characteristics and can achieve high-precision measurement even in the engine compartment of vehicles.

Accumulation function of current and power with different polarities

The cumulative measurement of DC is to accumulate charging power and discharging power by polarity at a sampling rate of every 500kS/s, and measure the positive direction energy, negative direction energy, and the sum of positive and negative direction energy at the time of accumulation. Even when the battery is rapidly and repeatedly charged and discharged, it can accurately measure the amount of charge and discharge.

Through external control and linkage with surrounding devices

By using an external control button, it is possible to control the start/stop of accumulation and screen copying operations. When evaluating the performance of a real vehicle, it can also be easily controlled through manual switches or connected to other devices for time.

Power measuring instrument: PW3390 that balances high precision and maneuverability

The reading error of the power analyzer PW3390 is ± 0.04%, and the full-scale error is ± 0.05%, achieving very high power accuracy. 200kHz measurement bandwidth and smooth amplitude and phase characteristics up to high frequencies. Used together with the phase compensation function of the current sensor, it can accurately measure high-frequency and low power factor power. Very suitable for evaluating power conversion efficiency or analyzing EV/HEV inverter motors and harmonics.

Power measuring instrument: a power analyzer with rich current sensors to expand the measurement field

Current sensors that are suitable for various measurement scenarios, such as closed mouth type that emphasizes accuracy, high-precision clamp shape that emphasizes convenience, and flexible clamp shape that can measure large AC6000A. From secondary measurement of frequency converters to high current measurement of power lines, various power analyses such as voltage, current, power, harmonics, waveform, and efficiency calculations can be achieved through this compact body.

Specification Sheet

Basic parameters (accuracy guarantee time of 6 months, accuracy of 6 months per year multiplied by 1.25, accuracy guarantee time after adjustment of 6 months)

Measurement line Single phase 2-wire, single-phase 3-wire, three-phase 3-wire, three-phase 4-wire, voltage 4ch, current 4ch, insulation between channels
Basic measurement items Frequency, voltage effective value, voltage average rectified effective value conversion value, voltage AC component, voltage simple average value, voltage fundamental component, voltage peak+, voltage peak -, voltage total harmonic distortion rate, voltage ripple rate, voltage imbalance rate, current effective value, current average rectified effective value conversion value, current AC component, current simple average value, current fundamental component, current peak+, current peak -, current total harmonic distortion rate, current ripple rate, current imbalance rate, active power, apparent power, power factor, voltage phase angle, current phase angle, power phase angle, positive direction current, negative direction current, sum of positive and negative direction current, positive direction electrical energy, negative direction electrical energy, Directional electrical energy, positive and negative directional electrical energy, efficiency, and loss
Current accumulation, active power accumulation

PW3390-03: Motor torque, speed, motor power, slip rate
Harmonic measurement Number of measurement channels: 4ch, synchronous frequency range: 0.5 Hz to 5 kHz
Analysis frequency: up to 100 times
Interference measurement Number of calculation channels: 1ch (choose from CH1 to CH4)
Large analysis frequency: 200 k/50 k/20 k/10 k/5 k/2 kHz

Motor analysis
(PW3390-03)

Number of input channels: 3ch (CH A, CH B, CH Z)
Measurement items: voltage, torque, speed, frequency, slip rate, motor power
measurement range Voltage: 15-1500 V, 7-speed range
Current: 0.1 A~20 kA (the range structure may vary depending on the sensor used)
Power: 1.5000 W~90.00 MW (automatically determined based on voltage range/current range/measurement line combination)
Frequency: 0.5 Hz to 5 kHz

Fundamental wave accuracy
(45Hz~66Hz)

Voltage: ± 0.04% rdg. ± 0.05% fs
Current: ± 0.04% rdg. ± 0.05% f.s (with additional accuracy of current sensor)
Power: ± 0.04% rdg. ± 0.05% f.s (with additional accuracy of current sensor)
Synchronous frequency range 0.5 Hz〜5 kHz
frequency band DC, 0.5 Hz〜200 kHz
data update rate 50 ms (harmonic measurement/frequency measurement: depending on frequency below 45Hz)
Display update rate 200 ms (independent of internal data update rate, waveform and FFT depend on the image)
Auto save function Save to CF card at intervals (cannot use USB flash drive): OFF, 50 ms~60 min, switch to 15 levels
interface USB (communication/storage), LAN, CF card, RS-232C, synchronous control, external control
power supply AC 100〜240 V, 50/60 Hz, 140 VA
Volume and weight 340 W × 170 H × 156 D mm, 4.6 kg
attachment User manual x 1, measurement guide x 1, power cord x 1, USB cable (0.9m) x 1, input line label x 2, D-sub connector x 1 (PW3390-02, PW3390-03)