DRK0041 Fabric Permeability Tester

NegotiableUpdate on 01/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The DRK0041 fabric permeability tester is used to measure the water resistance of tight fabrics such as canvas, oilcloth, tarpaulin, tent cloth, rainproof clothing cloth, etc.

Product Details

Product details

Product Introduction

DRK0041 fabric permeability tester is used for tight fabrics such as canvas and oilcloth苫布Tent clothrainproofDetermination of water resistance of clothing fabrics and other materials.

Instrument standards:

GB19082 Technical Requirements for Disposable Protective Stocks 5.4.1. Water resistance

GB/T 4744 spinningTextile fabric_Determination of impermeability hydrostatic test

GB/T 4744 Testing and Evaluation of Waterproof Performance of Textiles, Hydrostatic Pressure Method and Other Standards.

Test Principle:

Under standard atmospheric pressure conditions, the test specimen is subjected to a continuous increase in water pressure on one side until water droplets seep out from the surface of the specimen, and the hydrostatic pressure borne by the specimen is used to represent the waterpenetrateRecord the resistance encountered by the fabric and the pressure at that time.

Instrument Features:

1The whole machine shell is made of metal baking paint, and the operating table and some accessories are made of special aluminum profiles. The fixtures are made of non steel materials

2The panel is made of imported special aluminum material and has metal buttons;

3The pressure measurement adopts high-precision pressure sensors and imported regulating valves, with a more stable pressurization rate and a larger adjustment range

4Color touch screen, beautiful and elegantMenu based operation mode, comparable in convenience to smartphones

5The core control components are manufactured by STMicroelectronics 32-bit multifunctional motherboard;

6Speed units can be switched freely, with kPa/min,mmH20/min,MmHg/min

7Pressure units can be switched freely, withkPa,mmH20,mmHgwait

8The instrument is equipped with a precision level detection device:

9The instrument adopts a desktop structure design that is robust and easy to move.

safety:

safety sign

Before opening and using the device, please read and understand all the operation and usage instructions.

Emergency power cut

In emergency situations, all power sources of the equipment can be disconnected. The instrument will immediately lose power and testing will stop.

Technical Specifications

Sample clamping method: manual

Measuring range0~300kPa (30mH20)/0~100kPa (10mH20)/0~50kPa (5mH20) range optional;

Resolution:0.01kPa(1mmH20);

Measurement accuracy:≤ 0.5% F · S;

Test frequency:≤ 99 times, optional deletion function;

Testing methods: Boosting method, constant pressure method, and other testing methods

Holding time of constant pressure method:0~99999.9S;

Timing accuracy: Shi0.1S;

Sample clamp area:100cm²;

Total testing time timing range:0~9999.9;

Timing accuracy: Shi0.1S;

Pressurization speed:0.5~50kPa/min (50~5000mmH2O/min) with arbitrary numerical settings;

power supplyAC220V、50Hz、250W

Overall dimensions:470x410x60 mm

Weight: Approximately25kg

install

Unpacking of instruments:

When you receive the device, please check if the wooden box has been damaged during transportationCarefully open the packaging box of the equipment and check for any damage to the components. Please report the damage to the carrier or our customer service department.

Debugging:

1. After unpacking the equipment, use a soft dry cotton cloth to wipe away dirt and packaging sawdust from all parts. Place it on a sturdy workbench in the laboratory and connect it to a gas source.

2. Before connecting the power supply, check whether the electrical parts are affected by moisture or other adverse phenomena.

Maintenance and upkeep

1. The instrument should be placed in a clean and stable foundation.

2. If the instrument is found to be working abnormally, please turn off the power in a timely manner to avoid damaging the components.

3. After installation, the instrument casing should be reliably grounded with a grounding resistance of ≤ 10.

4. After each experiment, the power switch should be turned off and the plug of the instrument should be unplugged from the power outlet.

5. After the experiment, drain the water and wipe it clean.

6. The working pressure of this instrument shall not exceed the range that the sensor can withstand.

troubleshooting

Fault phenomenon

Root cause analysis

solution

▪ After the plug is inserted correctly; After starting the power, there is no touch screen display

▪ Loose or damaged plug

▪ Damaged electrical components or loose (disconnected) or short circuited motherboard wiring

▪ The microcontroller is burnt out

▪ Re insert the plug

▪ Reconnect the wires

▪ Please have professionals inspect and replace damaged components on the circuit board

▪ Replace the microcontroller

▪ Test data error

▪ Sensor failure or damage

▪ retest

▪ Replace the damaged sensor

Note: Due to technological advancements, information may be changed without prior notice. The actual product in the future shall prevail.