Product name: DR6000 series multi parameter water quality analyzer is used to determine various parameters such as chemical oxygen demand (COD), ammonia nitrogen, total phosphorus, etc. in surface water, reclaimed water, urban sewage, and industrial wastewater.

Product Details

Shanghai Xinrui DR6000 series multi parameter water quality analyzer

Usage Overview

This product is a popular instrument specially designed for small and medium-sized enterprises. It has the advantages of complete functionality, simple operation, and high measurement accuracy. Used to determine various parameters such as chemical oxygen demand (COD), ammonia nitrogen, total phosphorus, etc. in surface water, reclaimed water, urban sewage, and industrial wastewater.

Product Features

Adopting imported high-quality integrated chips to ensure that the instrument can work stably for a long time; The standard curve of memory operation can be modified by users themselves, and it has the function of saving in case of power failure;

► Reliable positioning structure and independent dual path system can effectively avoid interference caused by stray light and accurately determine the ion concentration value in the sample;

Equipped with a single button parameter selection function, it can automatically complete the selection of light source, detector, and working curve. High degree of automation and simple operation;

► Cold light source narrowband interference monochromatic light processing system, equipped with customized 100000 hour high-intensity long-life cold light source, no worries about replacement;

The complete set is equipped with a digestion furnace, and the digestion temperature and timing can be set freely. The microcomputer heating and temperature control system has over temperature protection function, which can effectively save energy consumption;

► Independently develop rapid digestion reagents to ensure long-term stable and low-priced supply, effectively reduce user workload and sample testing costs, and comply with national standards.

Technical indicators

*COD determination anti chlorine interference: [CL -]<1000mg>1000mg>

PRODUCT MODEL

Measurement parameters

Measurement range

measuring accuracy

Measurement time

DR6000

COD、 Total phosphorus, ammonia nitrogen, turbidity

COD: segmented from 3 to 10000mg/L; Total phosphorus: 0-20mg/L segmented;Ammonia nitrogen: 0-50mg/L segmented; Turbidity: 3-500NTU

≤±5%~±10%

1-50 minutes

DR6000A

COD、 Ammonia nitrogen

COD: segmented from 3 to 6000mg/L; Ammonia nitrogen: 0-50mg/L segmented

≤±5%~±10%

1-50 minutes

DR6000B

COD、 Total phosphorus and ammonia nitrogen

COD: segmented from 3 to 6000mg/L; Total phosphorus: 0-10mg/L; Ammonia nitrogen: 0-50mg/L

≤±5%~±10%

1-50 minutes

DR6100

COD

Segmented from 5 to 6000mg/L

≤±5%~±10%

15-20 minutes

DR6100A

COD

15~1000mg/L

≤±5%~±10%

15-20 minutes

DR6100B

COD

Segmented from 15 to 1500mg/L (optional from 3 to 6000mg/L)

≤±5%~±10%

15-20 minutes

DR6200

total phosphorus

Segmented from 0 to 20mg/L

≤±5%

35-50 minutes

DR6200A

total phosphorus

0~10mg/L

≤±5%

35-50 minutes

DR6300

Ammonia nitrogen

0.02~50mg/L segmented

≤±10%

10-15 minutes

DR6300A

Ammonia nitrogen

0~12mg/L

≤±10%

10-15 minutes

DR6100A

COD

Desktop microcomputer, equipped with4 Hole disintegrator, measuring range:15~1000 mg/L

7800

DR6100B

COD

Desktop microcomputer, equipped with12 Hole disintegrator, measuring range:15~1500 mg/LSegmented (optional)3~6000mg/L)

9800

DR6100

COD

Desktop microcomputer, equipped with12 Hole disintegrator with printer, measuring range:COD:5~6000 mg/Lsegmentation

12800

DR6100M

Permanganate index

Desktop microcomputer, equipped with12 Hole disintegrator with printer,CODMn Measurement range:0.05~50 mg/Lsegmentation

12800

DR6200A

total phosphorus

Desktop microcomputer, equipped with12 Hole disintegrator, equipped with printer, measuring range0~10mg/Lsegmentation

10000

DR6200

total phosphorus

Desktop microcomputer, equipped with12 Hole disintegrator, equipped with printer, measuring range0~80mg/Lsegmentation

12000

DR6300A

Ammonia nitrogen

Desktop microcomputer, measurement range 0~20mg/L,(Expandable measurement range))

4800

DR6300

Ammonia nitrogen

Desktop microcomputer, equipped with printer, measuring range0~100mg/Lsegmentation

6200

DR6000A

CODAmmonia nitrogen

Desktop microcomputer, equipped with printer, equipped with12 Pore digester,

Measurement range:COD:3~6000mg/LAmmonia nitrogen:0~50 mg/L

14800

DR6000B

CODAmmonia nitrogen, total phosphorus

Desktop microcomputer, equipped with printer, equipped with12 Pore digester,

Measurement range:COD:3~6000mg/LAmmonia nitrogen:0~50 mg/LTotal phosphorus:0~20mg/Lsegmentation

16800

DR6000C

Ammonia nitrogen, total phosphorus, turbidity, hardness

Desktop microcomputer with printer and accessories12 Pore digester, measuring range: ammonia nitrogen0~50 mg/LSegmentation; total phosphorus0~20 mg/LSegmentation; Turbidity:3~500 NTUSegmentation; Total hardness:0-6mg/l

17800

DR6000

CODAmmonia nitrogen, total phosphorus, turbidity

Desktop microcomputer with printer and accessories12 Hole disintegrator, measuring range:COD:3~10000 mg/LSegmentation; Ammonia nitrogen0~50 mg/L

Segmentation; total phosphorus0~20 mg/LSegmentation; Turbidity:3~500 NTUSegmentation;

22200