Temperature control: room temperature drops by 20 ℃ (under certain conditions, 3 ℃ -100 ℃)
Display mode: Actual temperature: Four digit LED display
Set temperature: Four digit LED display
Maximum resolution: 0.1 degrees Set resolution: 0.1 degrees
Temperature control accuracy: 0.1 degrees
Temperature stability: 0.1 degrees
Number of columns that can be accommodated: 2
Power Supply: 220VAC 50HZ
External dimensions: 410*140*300mm
Heating box size: 360*40*40mm
All independent brand column temperature boxes come with a one-year warranty. If there are any quality problems within one year, they will be replaced with new ones!!!

Amoxicillin High Performance Liquid Chromatography (HPLC) Detection Scheme
-Sample processing procedure-
Accurately weigh about 25mg of the test sample and place it in a 50ml volumetric flask. Dissolve it in mobile phase and dilute it quantitatively to the mark. Shake well and filter through a needle filter to obtain the sample
-Chromatographic conditions-
Chromatographic column: Vertex C18:250mm × 4.6mm × 5 μ m
Mobile phase: Mobile phase A: Mobile phase B=2.5:97.5
Preparation method: Mobile phase A: Acetonitrile
Mobile phase B: 0.05mol/L potassium dihydrogen phosphate solution (adjusted to pH 5.0 with 2mol/L potassium hydroxide solution)
Wavelength: 254nm
Flow rate: 1.0 mL/min
Injection volume: 20ul
Instrument configuration:
Please click to view the image details
![]() |
501Plus high-pressure constant current infusion pumpProvides solvent and compression factor libraries, which can automatically perform solvent compensation...... | ![]() |
501Plus UV detectorThe original imported deuterium lamp used has a stable light source, extremely low baseline noise and drift. In addition, there is a tungsten lamp option, and the deuterium lamp has a warranty life of 1000 hours...... | ![]() |
7725i injection valveIt is currently the most advanced HPLC sample injection valve. By using quantitative ring full filling and partial filling methods, sample volumes ranging from 1 μ l to 5ml can be processed. |
![]() |
Solvent filterMade of ultra hard high-quality glass material, with uniform wall thickness, no bubbles, beautiful appearance, suitable for sterilization under high temperature and high pressure, good sealing performance, fast flow rate, and standard grinding mouth. |
![]() |
Kromastar chromatographic columnOur company has selected B-type ultra-high purity fully porous silicone gel (purity>99.999%) as the matrix...... | ![]() |
N2010 Chromatographic Data WorkstationIt is a two in one chromatographic data workstation launched by Zhejiang University Zhida. Multiple user choices and high cost-effectiveness. |