Cooling function column temperature box

NegotiableUpdate on 03/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The CTO-10T refrigeration function column temperature box uses automatic dual control instruments, which can work without any conversion as long as the working temperature is set and achieve computer reverse control; Install a Japanese miniature temperature sensor and temperature control meter that can automatically recognize the current temperature and adjust it, with a temperature control accuracy of up to 0.1 degrees; LED display for temperature measurement and actual temperature protection; Equipped with automatic over temperature alarm and power-off protection functions, it can be used safely and with confidence; Easy to install and use, can hold chromatography columns 100-250mm in length; The injection valve can be placed inside the column temperature box, and the mold can be fully opened to inject molded products. All high-precision imported controllers are used for stable and reliable operation, with high cost-effectiveness.
Product Details


Temperature control: room temperature drops by 20 ℃ (under certain conditions, 3 ℃ -100 ℃)

Display mode: Actual temperature: Four digit LED display

Set temperature: Four digit LED display

Maximum resolution: 0.1 degrees Set resolution: 0.1 degrees

Temperature control accuracy: 0.1 degrees

Temperature stability: 0.1 degrees

Number of columns that can be accommodated: 2

Power Supply: 220VAC 50HZ

External dimensions: 410*140*300mm

Heating box size: 360*40*40mm


All independent brand column temperature boxes come with a one-year warranty. If there are any quality problems within one year, they will be replaced with new ones!!!





Liquid phase detection application

阿莫西林.jpg

Amoxicillin High Performance Liquid Chromatography (HPLC) Detection Scheme

-Sample processing procedure-

Accurately weigh about 25mg of the test sample and place it in a 50ml volumetric flask. Dissolve it in mobile phase and dilute it quantitatively to the mark. Shake well and filter through a needle filter to obtain the sample

-Chromatographic conditions-

Chromatographic column: Vertex C18:250mm × 4.6mm × 5 μ m

Mobile phase: Mobile phase A: Mobile phase B=2.5:97.5

Preparation method: Mobile phase A: Acetonitrile

Mobile phase B: 0.05mol/L potassium dihydrogen phosphate solution (adjusted to pH 5.0 with 2mol/L potassium hydroxide solution)

Wavelength: 254nm

Flow rate: 1.0 mL/min

Injection volume: 20ul


Instrument configuration:点击图标.pngPlease click to view the image details


1440573823266754.jpg 501Plus high-pressure constant current infusion pumpProvides solvent and compression factor libraries, which can automatically perform solvent compensation...... 1440573847261977.jpg 501Plus UV detectorThe original imported deuterium lamp used has a stable light source, extremely low baseline noise and drift. In addition, there is a tungsten lamp option, and the deuterium lamp has a warranty life of 1000 hours...... 1440573962114593.jpg 7725i injection valveIt is currently the most advanced HPLC sample injection valve. By using quantitative ring full filling and partial filling methods, sample volumes ranging from 1 μ l to 5ml can be processed.
1440574013359745.jpg

Solvent filterMade of ultra hard high-quality glass material, with uniform wall thickness, no bubbles, beautiful appearance, suitable for sterilization under high temperature and high pressure, good sealing performance, fast flow rate, and standard grinding mouth.

1440574073101550.jpg Kromastar chromatographic columnOur company has selected B-type ultra-high purity fully porous silicone gel (purity>99.999%) as the matrix...... 1440574099482171.jpg N2010 Chromatographic Data WorkstationIt is a two in one chromatographic data workstation launched by Zhejiang University Zhida. Multiple user choices and high cost-effectiveness.