Product Features
1. Fire resistance function: This product can meet the 4-hour fire resistance combustion function, and can provide a 4-hour fire resistance test report and a full video of the test process. Reference standard: GB/T 9978.1-2008 Fire resistance test method for building components;
2. Explosion proof function: This product can meet the control function of explosive impact force of flammable and explosive chemicals during storage. The top of the product is equipped with an explosion vent, and an explosion-proof test report can be issued. Reference standards: GB3836.1-2010, GB3836.8-2014 Explosive Environment;
3. Lightning protection function: This product can meet the grounding resistance requirements of lightning rods, comply with the requirements of national standards for direct lightning protection and induced lightning protection, and reference standards: GB50057 Building Lightning Protection Design Specification, GB50343 Building Electronic Information System Lightning Protection Technical Specification;
4. Power outage alarm: This product is equipped with a power outage alarm system, and the response time of the alarm after power outage does not exceed 2 seconds. It can achieve sound and light alarm, as well as remote telephone and SMS alarm functions after power outage;
5. VOC concentration alarm: This product is equipped with a VOC alarm system (volatile organic compound concentration alarm), which can sound and light an alarm on site when the concentration of volatile organic compounds exceeds the set index. At the same time, the explosion-proof fan will automatically work to discharge volatile gases, reduce the VOC concentration in the cabinet, and ensure safety;
6. Smoke alarm: This product is equipped with a smoke alarm system that can trigger on-site sound and light alarms when smoke or irritating odors appear inside the cabinet; At the same time as the alarm, the explosion-proof fan will automatically work to discharge smoke or irritating gases, reduce the concentration of smoke or irritating gases in the cabinet, and ensure safety;
7. Combustible gas alarm: This product is equipped with a combustible gas alarm system, which can trigger an on-site sound and light alarm when the combustible gas exceeds the standard in the cabinet. At the same time, the explosion-proof fan will automatically work to discharge the combustible gas, reduce the concentration of combustible gas in the cabinet, and ensure safety;
8. Ventilation and filtration function: Each independent storage space of this product is equipped with 2 explosion-proof fans. The first fan is for timed exhaust, and the second fan is for combustible gas VOC、 Smoke alarm linkage can achieve simultaneous alarm and exhaust. Each fan outlet is equipped with a set of gas filtration device, which can effectively filter the exhaust gas;
9. Automatic fire extinguishing function: Each independent temporary storage space of this product is equipped with a set of heptafluoropropane fire extinguishing system, and a fire sensing sprinkler head is installed on the top. The fire extinguishing function can be automatically activated when the temperature inside the cabinet reaches 68 ℃;
10. Anti static function: A human body static discharge device is installed outside the cabinet, which can effectively export the static electricity carried by the human body, ensuring safe operation; At the same time, static electricity export ports are installed outside the cabinet to effectively export static electricity generated on the cabinet, ensuring safety;
11. Leakage emergency response function: An anti leakage collection tank is installed at the bottom of the cabinet to facilitate the collection of waste liquid in case of chemical leakage; Set up a waste liquid collection tank outside the cabinet and a waste liquid collection bucket inside to facilitate the safe collection and transportation of waste liquid inside the cabinet; Set up an eye wash outside the cabinet, which can be rinsed promptly after chemicals splash onto the human body;
12. Anti corrosion leakage collection function: The bottom and surrounding areas of the cabinet storing corrosive materials are decorated with strong corrosion-resistant PP sheets for secondary decoration, so that the cabinet will not be eroded even when corrosive materials leak;
13. Explosion proof monitoring: Each independent component of this productTemporary storage cabinet for hazardous chemicalsEach space is equipped with one explosion-proof camera; Install monitoring image collection equipment outside the cabinet.
14. Safety signs: Professional warning labels and identification labels that meet the requirements of emergency management for hazardous chemicals shall be posted outside the cabinet. Reference standard: GB20592 Chemical Classification, Warning Labels, and Warning Instructions Safety Regulations.
Design reference standards
01) GB 18597-2001 Pollution Control Standard for Hazardous Waste Storage 10) GB20592 Safety Specification for Classification, Warning Labels and Warning Instructions of Chemicals
02) GB/T 31190-2014 Technical Specification for Collection of Laboratory Waste Chemicals 11) GB190 Dangerous Goods Packaging Marking
03) GB13690 General rules for classification and hazard disclosure of chemicals 12) GB3836.1-2010 Explosive atmospheres
04) GB15258 Regulations for the Writing of Chemical Safety Labels 13) GB3836.8-2014 Explosive Atmosphere
05) GB15603 General rules for storage of commonly used hazardous chemicals 14) GB50058 Code for design of electrical installations in explosive and fire hazardous environments
06) GB17914 Technical Conditions for Storage and Maintenance of Flammable and Explosive Commodities 15) GB50016 Code for Fire Protection Design of Buildings
07) GB17915 Technical Conditions for Storage and Maintenance of Corrosive Commodities 16) GB50116 Design Specification for Automatic Fire Alarm System
08) GB17916 Technical Conditions for Storage and Maintenance of Toxic Commodities 17) GB/T 9978.1-2008 Fire Resistance Test Method for Building Components
09) GB18218 Identification of Major Hazardous Sources for Hazardous Chemicals 18) GB50057 Design Code for Lightning Protection of Buildings