GNST-990Stype
COD, ammonia nitrogen, total phosphorus, total nitrogenmulti-parameter water qualitymeasuring instrument
Product Introduction
GNST-990S adopts imported deuterium and tungsten lamp light sources, developed according to national environmental standards, with a brand new optical path design, internationally purchased accessories, high-performance configuration, 7-inch color touch display screen, directly displaying various scanning curves and spectra. It uses an ARM processor, which can perform more than ten data averaging calculations per second and store 2000 test data or 500 working curves. It can detect COD, ammonia nitrogen, total phosphorus, total nitrogen, and heavy metals. In standard detection of total nitrogen concentration in water, the determination of total nitrogen does not require the addition of concentrated sulfuric acid, making detection simpler and faster.
Application field
This series of instruments can perform qualitative and quantitative analysis of sample substances in the ultraviolet and visible spectral regions, and can be widely used in departments such as medicine and health, clinical testing, biochemistry, petrochemicals, environmental testing, food hygiene, and quality control. It can also be used as a teaching demonstration and experimental instrument for related courses in higher education institutions.
Measurement principle
The determination of COD is based on the "HJ/T 399-2007 Water Quality Chemical Oxygen Demand Rapid Digestion Spectrometric Method"
The determination of ammonia nitrogen is based on the "HJ 535-2009 Determination of Ammonia Nitrogen in Water Quality - Nessler's reagent spectrophotometric method"
The determination of total phosphorus is based on "GB 11893-89 Determination of total phosphorus in water quality - Ammonium molybdate spectrophotometric method"
The determination of total nitrogen is based on HJ636-2012 Water Quality Total NitrogenThe determination Alkaline potassium persulfate digestion UV spectrophotometry
Product Features
(1) Adopting a high-resolution (1024 * 768) dot matrix 7-inch color touch LCD display, the operation interface is friendly and simple.
(2) The instrument supports cloud storage function and can easily achieve WeChat scanning, which facilitates customers' application scenarios.
(3)The instrument adoptsThe "Shining Holographic Grating" high-resolution C-T monochromator uses a 24 bit high-precision AD chip from AD Corporation in the United States, enabling economical instruments to have high resolutionqualityLow impurity that only instruments possessRemote control(Less than)0.1T%)、 High precision and high stability (0.002A).
(4)The instrument has powerful storage capabilities and can store data2000 pieces, 96 working curves, convenient for customers to use.
(5)Instrument standard configurationUSB interface, WIFI module, and Bluetooth module. Can achieve wireless Bluetooth printing; Can quickly manage spectral data for easy data processing; It can be exported directly through a USB flash drive, and the exported data can be opened and edited directly in EXCEL, making it convenient for customers to apply.
(6)Support fast scanning, fast wavelength movement speed, can achieve3000nm/min; Automatic wavelength setting, automatic light switching setting, connected to computer software, can achieve wavelength scanning, dynamic measurement, quantitative measurement, nucleic acid measurement, wavelength superposition, integral derivative, etcMultiple functions.
Technical Specifications
| model | GNST-990Smulti-parameter water qualitymeasuring instrument | |||
| Test Item | COD | ammonia nitrogen | Total Phosphorus | Total Nitrogen |
| Testing Scope | 5-5000mg/L | 0.01-100mg/L | 0.01-15mg/L | 0.01-80mg/L |
| Testing Standard | HJ/T399-2007 | HJ/535-2009 | GB/11893-89 | HJ636-2012 |
| Detection Principle | Potassium dichromate method | Nessler's reagent method | Ammonium molybdate method | Alkaline potassium persulfate digestion UV spectrophotometry |
| relative error | ≤8% | |||
| display screen | 7Inch high resolution1024*600touch screen | |||
| Monochromator | Holographic glitter gratingC-TMonochromator | |||
| grating | 1200 | /mm | |||
| light source | Tungsten and deuterium lamp light sources | |||
| Luminous range | 0-200%T,-0.3-3A | |||
| Wavelength mode | automatic | |||
| Wavelength accuracy | 0.5nm | |||
| wavelength repeatability | ≤3% | |||
| miscellaneous | 0.05T% | |||
| wavelength range | 190-1100 | |||
Shipping List
| serial number | name | quantity | serial number | name | quantity |
| 1 | host | 1 unit | 8 | cleaning cloth | 1 piece |
| 2 | Dissolving instrument | 1 unit | 9 | test tube rack | 1a |
| 3 | pipette | 2 of them | 10 | Pipette tip | 2 packs |
| 4 | glove | 2 pairs | 11 | 16mm colorimetric tube | 10 of them |
| 5 | power cord | 1 piece | 12 | Instruction Manual | 1 copy |
| 6 | Certificate of Conformity | 1 copy | 13 | Warranty Card | 1 copy |
| 7 | Supporting reagents | 1 set |
|
|
|