E-mail
531919146@qq.com
-
Phone
13213003605
-
Address
No. 22, 10th Floor, Building 10, No. 228 West Fourth Ring Road, High tech Zone, Zhengzhou City
Henan Kailu Electronic Technology Co., Ltd
531919146@qq.com
13213003605
No. 22, 10th Floor, Building 10, No. 228 West Fourth Ring Road, High tech Zone, Zhengzhou City
Product advantages and features:
★ High reliability, no moving parts
The light source uses a pulsed xenon lamp with a lifespan of 5-10 years, calculated at 3 times per secondLifespan of up to 10 yearsPulsed xenon lamps are cold light sources with long lifespan, good stability, and no preheating time.
★ Modular design and easy maintenance
The detector and gas chamber are connected by optical fibers, which are easy to replace and have low maintenance costs. Adopting modular design, high reliability, good scalability, and easy maintenance.
★ High measurement accuracy and good stability
adoptInfrared absorption spectroscopyGas analysis technology. Low detection limit and small temperature drift. The range ratio can reach 10:1, with a low range of 0-10ppm and a low detection limit of 100ppb. It supports dual range switching;
★rich interfacesA friendly human-machine interface
It can be accessed through communication methods such as RS-485 and RS-232, with a touch screen human-machine interface that is easy to operate and use, providing convenience for the daily operation, maintenance, and management of the instrument.
Application scenarios
This system is mainly used in situations where combustible or toxic gases need to be detected, displaying the detected gas concentration. When the alarm set value is triggered on site, the system will automatically proceedSuch as sound and light alarms, fan exhaust, and solenoid valve actionWaiting for control, it can remotely send alarm information to mobile applications and other extended functions through WIFI. The controller is non explosion proof and should be installed in a safe area.
Typical application industries:
1. Monitoring of desulfurization, denitrification, and flue gas emissions in thermal power plants
2. Monitoring of flue gas emissions at the kiln head and tail of cement plants
3. Monitoring of flue gas emissions from metallurgical plants (steelmaking, ironmaking, aluminum industry, etc.)
4. Monitoring of flue gas emissions in petrochemical plants, etc
Product Parameters
Smoke temperature limit: |
0-300 ℃ (customizable) |
sampling method |
Direct extraction |
Equipment requirements for vibration |
no vibration |
Overall system compressed air requirements |
Above 0.4Mpa, without oil or water |
High gas consumption |
2.2m3/h |
average gas consumption |
0.45m3/h |
Atmospheric flow rate (L/min) |
2 |
Rated air flow rate (L/min) |
1.5 |
size |
80cmX80cmX200cm |
weight |
About 150KG |
Temperature of heat tracing pipeline |
120℃-200℃ |
Probe heating temperature |
120℃-200℃ |
Protection level |
Cabinet IP42, other IP65 |
power supply |
220VAC±10%,>3000W |
ambient temperature |
-20℃~50℃ |
ambient humidity |
5% Rh-95% Rh (non condensing) |
external output |
4-20mA/RS232/RS485 |
Standard gas |
8L steel cylinder |