BCNX-YY08 Oil Fume Online Monitoring Instrument
The BCNX-YY08 oil fume online monitoring instrument uses a new technology to detect three parameters: oil fume concentration, particulate matter, and non methane total hydrocarbons in the oil fume pipeline, and uploads the data information in real time. It can also expand the monitoring of the status of fans and purifiers, and display real-time monitoring information on the platform and device LCD screens to provide real and effective pollution data, thus truly achieving the goal of online monitoring of oil fume.
Application Scenario:
Scenarios where restaurants, hotels, resorts, and residential areas produce cooking fumes
Features:
1. Specialized oil fume sensing technology, high-precision analog acquisition unit
2. Can connect four controlled devices, monitor and remotely control the switch status
3. According to the requirements, it can support self reporting intervals for data
4. The controlled equipment overcurrent protection system automatically disconnects when the current exceeds the limit for 6 seconds, ensuring safety and reliability
performance parameters
Oil fume concentration measurement parameters:
monitoring method |
electrochemistry |
measurement range |
30000 ug/m3 |
measurement accuracy |
±10% |
zero drift |
1 hour zero drift not exceeding ± 0.5mg/m2 |
linear error |
≤10% |
||
accuracy |
The relative error of the average result measured by the reference method should not exceed 20% of the soil |
||||
insulation resistance |
≥20MΩ |
Working Voltage |
220VAC |
measurement period |
1 minute |
Withstand Voltage |
No abnormal phenomena (arc and breakdown) |
power |
8W |
||
Operating Temperature |
0℃~+70℃ |
Operating Humidity |
5% -95% (non condensing garden) |
||
probe size |
24x 248mm (drilling diameter of 25/26mm is sufficient) |
||||
Particle measurement parameters:
Detection Principle |
Principle of Light Scattering |
resolution |
1ug/m3 |
Testing Scope |
0~ 20mg/m3(Optional 02000g/m)3; 0-10mg/m3; 0-20mg/m3) |
||
Non methane total hydrocarbon measurement parameters:
Detection range |
0-30ppm/0-1000ppm |
resolution |
01ppm/0.1ppm |
working principle |
Semiconductor/PID photonics (optional) |
||
(* Note: The above parameter configurations can be customized by users according to their needs)