BCNX-YY08 Catering Oil Fume Online Monitoring System

NegotiableUpdate on 01/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

BCNX-YY08 Oil Fume Online Monitor BCNX-YY08 Oil Fume Online Monitor uses a new technology to detect three parameters: oil fume concentration, particulate matter, and non methane total hydrocarbons in the oil fume pipeline, and uploads the data information in real time

Product Details

BCNX-YY08 Oil Fume Online Monitoring Instrument


The BCNX-YY08 oil fume online monitoring instrument uses a new technology to detect three parameters: oil fume concentration, particulate matter, and non methane total hydrocarbons in the oil fume pipeline, and uploads the data information in real time. It can also expand the monitoring of the status of fans and purifiers, and display real-time monitoring information on the platform and device LCD screens to provide real and effective pollution data, thus truly achieving the goal of online monitoring of oil fume.


Application Scenario:

Scenarios where restaurants, hotels, resorts, and residential areas produce cooking fumes


Features:

1. Specialized oil fume sensing technology, high-precision analog acquisition unit

2. Can connect four controlled devices, monitor and remotely control the switch status

3. According to the requirements, it can support self reporting intervals for data

4. The controlled equipment overcurrent protection system automatically disconnects when the current exceeds the limit for 6 seconds, ensuring safety and reliability


performance parameters

Oil fume concentration measurement parameters:

monitoring method

electrochemistry

measurement range

30000 ug/m3

measurement accuracy

±10%

zero drift

1 hour zero drift not exceeding ± 0.5mg/m2

linear error

≤10%

accuracy

The relative error of the average result measured by the reference method should not exceed 20% of the soil

insulation resistance

≥20MΩ

Working Voltage

220VAC

measurement period

1 minute

Withstand Voltage

No abnormal phenomena (arc and breakdown)

power

8W

Operating Temperature

0℃~+70℃

Operating Humidity

5% -95% (non condensing garden)

probe size

24x 248mm (drilling diameter of 25/26mm is sufficient)

Particle measurement parameters:

Detection Principle

Principle of Light Scattering

resolution

1ug/m3

Testing Scope

0~ 20mg/m3(Optional 02000g/m)3; 0-10mg/m3; 0-20mg/m3)

Non methane total hydrocarbon measurement parameters:

Detection range

0-30ppm/0-1000ppm

resolution

01ppm/0.1ppm

working principle

Semiconductor/PID photonics (optional)

(* Note: The above parameter configurations can be customized by users according to their needs)