The BCNX-CEMS01 continuous monitoring system for flue gas emissions consists of a particulate matter measurement subsystem, a gaseous pollutant measurement subsystem, a flue gas parameter measurement subsystem, and a data acquisition and analysis subsystem. By directly measuring and analyzing (particulate matter) and sampling (gaseous pollutants), the concentration of pollutants in the flue gas is determined, and the flue gas temperature, pressure, flow rate, oxygen content, and emissions are also measured; Display reports of various monitoring parameters.
Product Introduction
System composition:
1. Particle measurement subsystem:
Smoke and dust analyzer: measures the smoke and dust content. Including: 01 host, probe 02 signal output: 4-20mA
2. Gaseous pollutant measurement subsystem:
(1) Gas analyzer. It has calibration function. The calibration time and cycle shall be determined according to the on-site situation
(2) Sampling probe. Equipped with self heating and temperature control functions
(3) Temperature controlled heat tracing sampling pipeline, the material of the sampling tube is polytetrafluoroethylene
(4) The preprocessing system includes: refrigerators, drainage pumps, anti-corrosion sampling pumps, precision filters, solenoid valves, etc
3. Smoke parameter measurement subsystem:
(1) Online monitoring instruments for temperature, pressure, flow rate, etc
4. System control, data acquisition, and data processing system:
(1) Hardware of data acquisition and processing system
(2) Continuous monitoring system software for flue gas emissions
Features:
(1) High accuracy: using ultraviolet spectroscopy analysis technology, the influence of moisture is small, and the accuracy and sensitivity are high
(2) Convenient and practical: display storage and preprocessing units integrated into the body. Easy to install and operate
(3) Strong stability: Key components are selected from world-class products, ensuring the stability of the entire equipment
configuration parameters
Smoke analyzer:
SO2 range |
(0-20-100-1000)ppm, Customizable range |
NO range |
(0-20-100-1000)ppm, Customizable range |
O2 range |
(0-25)% |
linearity |
Not exceeding ± 2% F.S/24h |
repetitiveness |
Not exceeding ± 0.5% F.S/24h |
zero drift |
Not exceeding ± 2% F.S/24h |
range drift |
Not exceeding ± 2% F.S/24h |
Operating Temperature |
(-20~﹢50)℃ |
Response time T90 |
<10S |
Overall dimensions |
3U&4U19”&320mm |
4~20mA input interface |
2 channels, flexible configuration |
4~20mA output interface |
5 channels, configurable output content |
Switch input interface |
8 channels, flexible configuration |
Switch output interface |
8 channels, configurable output content |
communication interface |
1 RS232, 1 RS485 |
power supply |
AC220V±20%,300W |
warm-up time |
30min |
Protection level |
IP65 |
Sample gas flow range |
1~2L/min |
Sample gas pressure range |
Current environmental pressure ± 0.1Bar |
Sample humidity range |
<95%RH |
Sample gas temperature range |
(0~50)℃ |
Integrated temperature pressure flow probe:
Flow velocity measurement range |
(0~15~40)m/s,(0~2)KPa |
output signal |
(4~20)mA |
measurement accuracy |
Not exceeding ± 2% |
response time |
<1S |
Differential pressure transmitter power supply |
DC24V |
Check the overvoltage limit of the transformer transmitter |
4.0MPa |
Pitot tube material |
316L |
Pitot tube length |
(0.5~2.0)m, customizable |
Pressure measurement range |
(-10~﹢10)KPa |
Temperature measurement range |
(0-300) ℃, customizable |
Backblowing solenoid valve power supply |
AC220V,50Hz |
Medium temperature range |
(-40~+500) ℃, customizable |
ambient temperature |
(-20~﹢50)℃ |
ambient humidity |
(0~85)%RH |
Install flange |
DN50 |
condenser
Startup time |
about 15 minutes |
Sample gas flow rate |
3L/min |
Number of cold chambers |
2-channel refrigeration |
Dew point at the inlet of the sample gas |
>﹢70℃ |
ambient temperature |
(-20~﹢50)℃ |
Introduction temperature of sample gas |
﹢140℃ |
Dew point at the exit |
3℃ |
Dew point stability |
0.5K |
pressure loss |
40Pa |
refrigerant |
R12 0.1kg |
Overall dimensions |
355×250×295mm |
Gas interface |
Φ 6 interface |
weight |
20kg |
Power supply and power consumption |
AC 220V、50Hz、500W |