Automatic pour point analyzer

NegotiableUpdate on 11/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

● Brief introduction: 1) Complies with cloud point standards ASTM D2500, D5771, D5772, D5773; IP

Product Details

Automatic pour point analyzer

Brief introduction:

1) Complies with the cloud point labelASTM D2500, D5771, D5772, D5773; IP219、IP444、IP445、IP446; DIN51597; ISO3015; 2) Meets pour point standards ASTM D97, D5950, D5853; IP15、IP441; ISO3016; 3) Measurable pour point point of petroleum samplesLike biological firewoodOil, various petroleum products, crude oil, motor and engine fuels, additives, lubricants, etc; 4) Measurement range of pour point point:+80 ℃~-80 ℃; 5) Temperature resolution: 0.06 ℃;

Technical Features:

1) Meets cloud point standards ASTM D2500, D5771, D5772, D5773; IP219、IP444、IP445、IP446; DIN51597; ISO3015; Pour point standards ASTM D97, D5950, D5853; IP15、IP441; ISO3016;

2) Can measure the pour point of petroleum samples, such as biodiesel, various petroleum products, crude oil, motor and engine fuels, additives, lubricants, etc., ranging from+80 ℃ to -80 ℃;

3) Test tank: Provide tank size and capacity according to standard method requirements; The sample solution is labeled; The top clip can fix the glass tube and the analysis head; Silver plated bottom with scratch resistant film protection;

4) Cooling system: built-in fluorine free air compressor; Single pole compressor, with a minimum temperature of -40 ℃; Bipolar compressor, with a minimum temperature of -85 ℃;

5) Safety measures: Pressure controller, used for single pole compressors; Pressure controller, used for bipolar compressors; Thermostat is used for

6) CE safety mark;

Measurement technical indicators:

1) Temperature unit: ℃;

2) Measurement range of pour point point:+80 ℃~-80 ℃;

3) Temperature resolution: 0.06 ℃;

4) Temperature accuracy: ± 0.1 ℃;

5) Temperature repeatability/reproducibility: meets or exceeds the requirements of standard methods;

Software functions and features:

1) Analysis menu:

2) Diagnostic menu:

3) Calibration menu:

4) Data processing:

Ordering information:

1) NewLab100/300/1: Imported automatic pour point analyzer,+80 ℃~-40 ℃, 2 test heads, single pole compressor;

2) NewLab1300/1300/1: Imported automatic pour point analyzer,+80 ℃~-40 ℃, 2 test heads, single pole compressor;

3) NewLab100/300/2: Imported automatic pour point analyzer,+80 ℃~-80 ℃, 1 test head, bipolar compressor;

4) NewLab1300/1300/2: Imported automatic pour point analyzer,+80 ℃~-80 ℃, 2 test heads, bipolar compressor;

Optional accessories:

1) LAB-XXX/005-03: Heater+automatic adhesion+insulation;

2) LAB-XXX/005-04: Thermal switch;

3)LAB-XXX/005-06: PT100 浴槽;

4) LAB-XXX/007-02: Static Relay;

5) LAB-XXX/007-04: PCB fuses, 10 pieces/pack;

6) LAB-XXX/006-01: Cooling liquid valve+fasteners;