Welcome Customer !

Membership

Help

Beijing Diesel Instrument Co., Ltd
Custom manufacturer

Main Products:

mechb2b>Products

Beijing Diesel Instrument Co., Ltd

  • E-mail

    simonwaj@163.com

  • Phone

    13601217611

  • Address

    Room 327, Unit 3, No. 88, East Zone 1, Tiantongyuan, Changping District, Beijing

Contact Now

Automatic oxygen bomb calorimeter

NegotiableUpdate on 11/20
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

● General characteristics: 1) Application areas: coal, food (production and research and development), animal feed, cement production, brick kiln production, ammunition, explosions

Product Details

Automatic oxygen bomb calorimeter

● General characteristics:
1) Application areas: coal, food (production and research and development), animal feed, cement production, brick kiln production, ammunition, explosives, liquid fuel, etc;
2) Meets and exceeds the standard requirements of DIN, ASTM, and ISO, specifically ASTM D240-02、D5865-04、D4809-00、D5468-02、E144-94、E711-87、British BS 4791:1985、DIN 51900-2、ISO 1928;
3) It is a highly advanced, fully automatic calorimeter system that has been researched by our senior engineers for many years, utilizing the latest technology and the highest quality materials;
4) It can meet the demand for a large number of samples and is very suitable for users who need to process 10 or more calorific value CV samples per hour;
5) Fully automatic operation, temperature and calculated values are ready for you to read;
6) 7 calorimeters can work together through networking;
7) The measurement is fast and accurate, taking only 2 to 2.5 minutes each time;
8) Isothermal design, patented oxygen bomb tank does not require water (no bucket, overflow, or measurement needs);
9) Large capacity memory storage, capable of storing over 2000 measurements, including operating conditions and user statistics;
10) Manual or automatic quality data input, through keyboard, balance or computer;
11) Automatic calibration, such as for ignition wires, cotton, door plugs, etc; 255 automatic tank recognition systems;
12) Automatic calibration, each tank comes with 10 stored calibration curves for standard deviation;
13) Calibration sensors are built into each tank; Each tank is intelligent, equipped with fault diagnosis and microprocessor;
14) Adjustable ignition limit; High and low sample quality limitations; The testing cycle can be adjusted;
● Software features:
1) Users can easily operate and perform necessary or daily operations;
2) Automatic result recovery, which can be used to select or specify format data processing;
3) Weighing station operation; Calorimeter and tank settings; Correction management; Daily management and maintenance;
4) Organizing files, printing or other operational functions, including data output to regular formats;
5) Real time temperature curve display; Networking status display;
6) Measurement and analysis of chemical samples; Color interface, compatible with any Microsoft operating system;
● More features:
1) Computer, balance, calorimeter interface; The ignition voltage can be adjusted for different ignition wires;
2) Real time alarm clock, can last for 1 week; The power consumption is 1W;
3) Each tank contains manufacturer and historical information;
Technical features of CAL2K-1 calorimeter host:
1) Operating temperature: 0-60 ℃; Repeatability 0.1 (% RSD); Temperature resolution 0.000001 ℃;
2) Calorific value resolution: 0.001 (MJ/kg)
3) Calibration: Calibrate through calibration curves, store 10 calibration curves, and automatically correct standard deviation;
4) Result: Each tank has 10 data points and 1 calorimeter per hour;
5) Size WDH: 280x400x290mm; Weight: 9Kg;
● System repeatability:
1) Average value: Sample 16.54; Minimum value: Sample 16.52; Maximum value: Sample 16.57;
2) Maximum deviation from the mean: sample 0.03 (ISO index requirement 0.05);
3) Minimum deviation from mean: Sample -0.02 (ISO index requirement -0.05);
4) Standard deviation: Sample 0.02;
5) Relative standard deviation (% RSD): Sample 0.10% (ISO specification requirement 0.20%, ASTM 0.15%);
6) Note:% RSD=(standard deviation)/(mean) * 100;
● Instrument configuration suggestions:
1. The minimum system requires manual input of sample quality:
1) 1 × CAL2k-1 automatic oxygen bomb calorimeter; 1 × CAL2k-2 cooler; 1 × CAL2k-4 oxygen bomb tank body; 1 × CAL2k-3 inflation station; 2) Optional accessories: 2 x CAL2k-4 oxygen bomb tanks, which can increase working capacity;
2. Standard system, capable of automatically inputting sample quality:
1) 1 x Sartorius electronic balance, to be purchased locally; 1 × CAL2k-1 automatic oxygen bomb calorimeter; 1 × CAL2k-2 cooler; 2 x CAL2k-4 oxygen bomb tank body; 1 × CAL2k-3 inflation station; 2) Optional accessories: A, 3 or 4 x CAL2k-4 oxygen bomb tank body; B、 Networked system, which can be used for direct automatic sample quality input; C、 Multi connected CAL2k-1 automatic oxygen bomb calorimeter (up to 7);
3. Calorimeter system with central processor:
1) It can be used for batch processing of multiple calorimeters, multiple oxygen bomb tanks, and multiple operators; 2) Connectable: A. Electronic balance, to be purchased locally; B、 Computer keyboard: a) keyboard input; b) Encoding scanner; c) Both of the above are present; C、 Computer and RS232 interface;
● Instrument ordering information:
1) CAL2k-1: Calorimeter;
2) CAL2k-1-KT: Calorimeter installation package (including: printed operation manual, CD operation manual, CD software, 2 bottles of benzoic acid tablets (50), 5 crucibles, 1000 ignition cotton, preparation table, wire brush, balance wire);
3) CAL2k-2: Cooler;
4) CAL2k-2-KT: Cooling installation package (including: room temperature wire, 10m water pipe, 3 water pipe clamps);
5) CAL2k-3: inflation station;
6) CAL2k-3-KT: Installation package for inflation station (including: 1m high-pressure pipe, oxygen pressure reducing valve, 2 flow regulating O-rings, 5 nozzle O-rings, operating hook, pressure relief cap);
7) CAL2k-4: Oxygen bomb canister; &, lt;, /SPAN>
8) CAL2k-4-KT: Installation package for oxygen bomb canister (including: center electrode, external electrode, converter plate, 5 ignition wires, 10 top and bottom O-rings, 5 O-rings for cover);
Other optional accessories:
9) CAL2k PCC: Computer Cable; 10) CAL2k PCS: Computer software; 11) CAL2k CIC: Connecting wires between calorimeters; 12) CAL2K-5: Central Processing Station; 13) REGULATOR: Oxygen pressure reducing valve;
Accessories that require local procurement:
14) Electronic balance: It is recommended to purchase Sartorius CP64. Similar instruments can also be used, but the following conditions must be met: 1) Analytical balance with dust cover, 2) Resolution: 0.1mg, 3) Output: RS232 interface;
15) Faucet connector;