● General characteristics: 1) Application areas: coal, food (production and research and development), animal feed, cement production, brick kiln production, ammunition, explosives, liquid fuel, etc; 2) Meets and exceeds the standard requirements of DIN, ASTM, and ISO, specifically ASTM D240-02、D5865-04、D4809-00、D5468-02、E144-94、E711-87、British BS 4791:1985、DIN 51900-2、ISO 1928; 3) It is a highly advanced, fully automatic calorimeter system that has been researched by our senior engineers for many years, utilizing the latest technology and the highest quality materials; 4) It can meet the demand for a large number of samples and is very suitable for users who need to process 10 or more calorific value CV samples per hour; 5) Fully automatic operation, temperature and calculated values are ready for you to read; 6) 7 calorimeters can work together through networking; 7) The measurement is fast and accurate, taking only 2 to 2.5 minutes each time; 8) Isothermal design, patented oxygen bomb tank does not require water (no bucket, overflow, or measurement needs); 9) Large capacity memory storage, capable of storing over 2000 measurements, including operating conditions and user statistics; 10) Manual or automatic quality data input, through keyboard, balance or computer; 11) Automatic calibration, such as for ignition wires, cotton, door plugs, etc; 255 automatic tank recognition systems; 12) Automatic calibration, each tank comes with 10 stored calibration curves for standard deviation; 13) Calibration sensors are built into each tank; Each tank is intelligent, equipped with fault diagnosis and microprocessor; 14) Adjustable ignition limit; High and low sample quality limitations; The testing cycle can be adjusted; ● Software features: 1) Users can easily operate and perform necessary or daily operations; 2) Automatic result recovery, which can be used to select or specify format data processing; 3) Weighing station operation; Calorimeter and tank settings; Correction management; Daily management and maintenance; 4) Organizing files, printing or other operational functions, including data output to regular formats; 5) Real time temperature curve display; Networking status display; 6) Measurement and analysis of chemical samples; Color interface, compatible with any Microsoft operating system; ● More features: 1) Computer, balance, calorimeter interface; The ignition voltage can be adjusted for different ignition wires; 2) Real time alarm clock, can last for 1 week; The power consumption is 1W; 3) Each tank contains manufacturer and historical information; Technical features of CAL2K-1 calorimeter host: 1) Operating temperature: 0-60 ℃; Repeatability 0.1 (% RSD); Temperature resolution 0.000001 ℃; 2) Calorific value resolution: 0.001 (MJ/kg) 3) Calibration: Calibrate through calibration curves, store 10 calibration curves, and automatically correct standard deviation; 4) Result: Each tank has 10 data points and 1 calorimeter per hour; 5) Size WDH: 280x400x290mm; Weight: 9Kg; ● System repeatability: 1) Average value: Sample 16.54; Minimum value: Sample 16.52; Maximum value: Sample 16.57; 2) Maximum deviation from the mean: sample 0.03 (ISO index requirement 0.05); 3) Minimum deviation from mean: Sample -0.02 (ISO index requirement -0.05); 4) Standard deviation: Sample 0.02; 5) Relative standard deviation (% RSD): Sample 0.10% (ISO specification requirement 0.20%, ASTM 0.15%); 6) Note:% RSD=(standard deviation)/(mean) * 100; ● Instrument configuration suggestions: 1. The minimum system requires manual input of sample quality: 1) 1 × CAL2k-1 automatic oxygen bomb calorimeter; 1 × CAL2k-2 cooler; 1 × CAL2k-4 oxygen bomb tank body; 1 × CAL2k-3 inflation station; 2) Optional accessories: 2 x CAL2k-4 oxygen bomb tanks, which can increase working capacity; 2. Standard system, capable of automatically inputting sample quality: 1) 1 x Sartorius electronic balance, to be purchased locally; 1 × CAL2k-1 automatic oxygen bomb calorimeter; 1 × CAL2k-2 cooler; 2 x CAL2k-4 oxygen bomb tank body; 1 × CAL2k-3 inflation station; 2) Optional accessories: A, 3 or 4 x CAL2k-4 oxygen bomb tank body; B、 Networked system, which can be used for direct automatic sample quality input; C、 Multi connected CAL2k-1 automatic oxygen bomb calorimeter (up to 7); 3. Calorimeter system with central processor: 1) It can be used for batch processing of multiple calorimeters, multiple oxygen bomb tanks, and multiple operators; 2) Connectable: A. Electronic balance, to be purchased locally; B、 Computer keyboard: a) keyboard input; b) Encoding scanner; c) Both of the above are present; C、 Computer and RS232 interface; ● Instrument ordering information: 1) CAL2k-1: Calorimeter; 2) CAL2k-1-KT: Calorimeter installation package (including: printed operation manual, CD operation manual, CD software, 2 bottles of benzoic acid tablets (50), 5 crucibles, 1000 ignition cotton, preparation table, wire brush, balance wire); 3) CAL2k-2: Cooler; 4) CAL2k-2-KT: Cooling installation package (including: room temperature wire, 10m water pipe, 3 water pipe clamps); 5) CAL2k-3: inflation station; 6) CAL2k-3-KT: Installation package for inflation station (including: 1m high-pressure pipe, oxygen pressure reducing valve, 2 flow regulating O-rings, 5 nozzle O-rings, operating hook, pressure relief cap); 7) CAL2k-4: Oxygen bomb canister; &, lt;, /SPAN> 8) CAL2k-4-KT: Installation package for oxygen bomb canister (including: center electrode, external electrode, converter plate, 5 ignition wires, 10 top and bottom O-rings, 5 O-rings for cover); Other optional accessories: 9) CAL2k PCC: Computer Cable; 10) CAL2k PCS: Computer software; 11) CAL2k CIC: Connecting wires between calorimeters; 12) CAL2K-5: Central Processing Station; 13) REGULATOR: Oxygen pressure reducing valve; Accessories that require local procurement: 14) Electronic balance: It is recommended to purchase Sartorius CP64. Similar instruments can also be used, but the following conditions must be met: 1) Analytical balance with dust cover, 2) Resolution: 0.1mg, 3) Output: RS232 interface; 15) Faucet connector; |