The automatic dosing control system for chemical nickel deposition is applied to the automatic dosing control of chemical nickel plating production line. Analysis principle: The nickel ion concentration in the plating solution is analyzed through photoelectric induction principle, and the pH value is measured by the pH electrode

Product Details

Chemical nickel deposition automatic dosing

control system

Applied to chemical nickel plating production line solution

Automatically add controls


Analysis principle: Analyze the nickel ion concentration in the plating solution through photoelectric induction principle
The pH value is measured by a pH electrode. Process of adding medicine:
1. The dosing pump pumps medication A, B, C, and pH regulator from the storage tank to the corresponding dosing chamber;
2. The host sends a dosing signal and opens the solenoid valve at the lower outlet of the dosing cylinder;
3. The medicine flows into the plating tank, and the dosing process is completed.

Automatic dosing control system for nickel plating solutionMain performance and features:
Adopting imported controller host, high precision and stability.


Column type dosing design, more accurate dosing amount, strictly follow the set ratio for dosing, and the dosing amount can be adjusted each time.
Defoamer function, eliminating the influence of bubbles on nickel content analysis.


Excellent cooling function, after the acidic plating solution is sampled and cooled, the liquid temperature can be reduced to around 35 ℃.
The dosing lag time setting function offsets the time required for the sampled plating solution to reach the sensor.

Equipped with manual/automatic selection buttons, easy to install and maintain.
With the C add stop button, you can choose to add two-component or three component concentrated solutions.

Nickel content analysis range: 0.01-25g/L
Resolution: 0.01 g/L
Accuracy: ± 0.01 g/L

PH value analysis range: 0-14PH
Resolution: 0.01PH
Accuracy: ± 0.01PH

Storage tank volume: 120L each for cylinders A, B, and C, and 60L for pH cylinder
Dosing cylinder volume: 1L each for A, B, C, and PH

Automatic dosing control system for nickel plating solution

Dimensions: Length 1400mm X Width 600mm X Height 1800mm
Weight: Approximately 150kg
Voltage: 220V
Power: 100W