E-mail
generalbj2009@gmail.com
-
Phone
18610478850
-
Address
No. 88, South West Fourth Ring Road, Fengtai District, Beijing
Jenino (Beijing) Technology Co., Ltd
generalbj2009@gmail.com
18610478850
No. 88, South West Fourth Ring Road, Fengtai District, Beijing
1、 Instrument Introduction
Atlantis is the culmination of GNR's 25 year direct reading spectrometer manufacturing technology, with analytical capabilities.
The quality manufacturing process enables Atlantis to meet various analytical requirements, suitable for: production process analysis and control; Quality Control; The special and complex applications of the R&D department.
Atlantis can be equipped with an MDS system, which combines PMT and CCD technologies to provide users with precision, flexible element range selection, and multi substrate applications. This instrument can quickly and accurately analyze the main alloying elements as well as trace elements. Examples include O, N, P, B... in steel, copper alloys, aluminum alloys, titanium alloys, and so on.
The precision and analytical quality achieved by using international standard samples to create working curves in manufacturers. If there are more complex and specialized applications, our experts can provide you with new analysis methods and solutions.
The optical chamber made of aluminum alloy is sturdy and reliable, with optimized Paschen Runge structure and high stability temperature and pressure control, which can make the system relatively isolated from external environmental conditions.
The readout system can simultaneously receive signals from photomultiplier tubes (PMT) and CCD detectors. All data display, analysis and processing are completed in one full band scan.
The variable frequency spark source controlled by PC can improve the accuracy of plasma, while also increasing repeatability and reducing detection time.
The analysis software is easy to operate, efficient and fast in daily analysis, and automatically standardized to support remote control through network connection.
The instrument has self diagnostic function and can automatically monitor the working status of the instrument.
2、 Main features
1. Quick analysis performance (only 20-30 seconds)
2. Dynamic range: from ppm to%
3. The open spark table and special small sample fixtures ensure that the instrument is suitable for analyzing metal samples of various shapes
4. Precision: better than 1% deviation
5. Excellent nitrogen and oxygen element analysis performance
6. High stability, high reliability
7. Multiple detection systems can be optionally configured to combine PMT with CCD technology, increasing the flexibility of upgrading instrument substrates and elemental analysis
8. High level standard sample calibration
9. PC controlled variable frequency high-energy pre spark (HEPS)
10. High precision temperature and pressure control
11. Advanced software features, easy to operate, and easy to master
12. Suitable for analysis of various metal materials
3、 Technical parameters
1. Vacuum optical system
■Baching Runge frame method, focal length: 750 mm
■Holographic diffraction grating, with 2400 or 3600 grating lines/mm (depending on the analysis software)
■Spectral range: 120-800 nm (depending on the analysis software)
■High sensitivity photomultiplier tube detection system
■A sealed optical chamber can avoid interference from dust and light.
■CCD modules can be added to enhance the analytical capabilities of the instrument.
2. Spectral lines
Each line includes:
There is a secondary slit on the mask
Optimizing a specific spectral line range using a photomultiplier tube
A reflector (depending on the position of the photomultiplier tube if necessary)
One acquisition channel
An adjustable high-voltage power supply
The number of analysis channels can reach 54, and multiple optical modules can be selected according to analysis requirements.
3. Temperature regulation
The light chamber and electronic components are installed in a temperature controlled environment, which can be set within a temperature range of+/-2 ℃ for the external environment.
This system avoids temperature fluctuations and ensures instrument stability.
4. Control and Collection
Electronic systems have automatic detection and data collection functions controlled by microprocessors
5. Digital spark source
■Digital spark source discharge is stable and not affected by power fluctuations
■High energy pre combustion technology, with a frequency of up to 1000 Hz
■The discharge parameters are password protected
6. Open spark table
■The open spark table can analyze samples of different shapes and sizes weighing up to 25 Kg
■Safety protection device
■The spark table is easy to disassemble and clean
■The electrode is easy to replace and repair
■The temperature of the spark table is maintained stable by a closed water cooling system with a cooling device, and the cooling process is digitally controlled
7. Vacuum system
■The vacuum stage is generated by a two-stage, high-performance turbo vacuum pump equipped with digital control
■Specially designed for detecting elements in the UV band
8. Analysis software
■Calculate the calibration curve, taking into account various matrices (references) for each element
■Create or modify analysis programs
■Support regular operation of function keys
■Optional output methods (intensity, intensity ratio, uncorrected concentration, corrected concentration, etc.)
■Selectable concentration units (ppm,%)
■Universal standardization
■Micro standardization
■Correction of interference between elements
■Automatic standardization
■Can print excitation data more than 100 times, standard deviation, relative standard deviation
■Alloy type identification (according to UNI, DIN, ASTM, etc.)
■Standard material library
■Brand identification
■Support calculation of C-equivalent or other parameters
■Can mark elements that are out of range
■It has the function of automatically correcting the number of excitations based on the analysis time
■Support statistical analysis and calculation
■Hard disk storage of data facilitates future research and analysis
■Can connect to external computers or central systems
■Analysis time:<30 seconds
9Computer and printer configuration
Reference configuration:
CPUPentium Core2、memory2GB
hard disk>160 GB 7.200turnTheDVD—CD-DVDRW-CDRW
monitorLCD 17”or19”LCD screen
Windows XPoperating system
Networkgraphics card, USBinterface…
keyboard, mouse
Printer: Color HPDeskjetPrinter, or equivalent product
10.Work environment:
■temperature range: 10 ~ 40℃
■Humidity environment: less than or equal to80%