The GC-9560-GAS propylene trace impurity chromatograph is suitable for detecting trace impurities in industrial ethylene and propylene gases. It can complete the analysis of hydrogen, oxygen, carbon monoxide, carbon dioxide, acetylene, and methanol in ethylene and propylene with one injection. The instrument is equipped with VICI's highly sensitive helium ionization (PDHID) detector; Adopting the central cutting and blowback technology with four valves and five columns of Huaai chromatography, the injection valve adopts a six way or ten way valve with blowback protection gas path, together with helium purifier, non dead volume sampling valve and other components to form a complete gas analysis solution.

Product Details

  • product description

1.GC-9560-GAS propylene trace impurity analysis chromatographSuitable for the detection of trace impurities in industrial ethylene and propylene gases, with a single injection for the analysis of hydrogen, oxygen, carbon monoxide, carbon dioxide, acetylene, and methanol in ethylene and propylene.

2.Instrument configurationVICIHighly sensitive helium ionization(PDHID)Detector; Adopting the central cutting and blowback technology with four valves and five columns of Huaai chromatography, the injection valve adopts a six way or ten way valve with blowback protection gas path, together with helium purifier, non dead volume sampling valve and other components to form a complete gas analysis solution.

3.Hydrogen detection limit reached0.01ppm

Applicable national standards:

GB/T 7715Industrial Ethylene

GB/T 7716Acrylic for Industrial Use

GB/T 3393Determination of Trace Hydrogen in Industrial Ethylene and Propylene Gas Chromatography Method

GB/T 3394Determination of Trace Carbon Monoxide, Carbon Dioxide, and Acetylene in Industrial Ethylene and Propylene Gas Chromatography Method

GB/T 12701Industrial Ethylene-Determination of Trace Methanol in Propylene

GB/T 3396Determination of Trace Oxygen in Industrial Ethylene and Propylene by Electrochemical Method

Helium ionization gas chromatograph for ethyleneDetection limits for 7 impurities in propylene(ppm

CO

CO2

CH3OH

C2H2

H2

PH3

O2

0.05

0.05

0.05

0.05

0.01

0.01

0.01