E-mail
1011090186@qq.com
-
Phone
15021595718, 15121127657,
-
Address
Jiading Industrial Park, Shanghai
Shanghai Xuansheng Scientific Instrument Co., Ltd
1011090186@qq.com
15021595718, 15121127657,
Jiading Industrial Park, Shanghai
cityAnalysis of Trace Hydrogen Sulfide in Natural Gas Pipeline Network by Gas Chromatography
The analytical equipment and methods provided by Shanghai Xuansheng Scientific Instrument Co., Ltd. can effectively and quickly detect the purity and residual amount of the substance. This analytical method complies with (and industry standards) data security and reliability, and is easy to operate
Xuansheng Science and Technology Engineer can provide a complete set of analytical instrument configuration and analysis solutions based on your analysis requirements and relevant standards for the product. Welcome to call for inquiries and request technical information.
We provide you with high-quality service
cityAnalysis of Trace Hydrogen Sulfide in Natural Gas Pipeline Network by Gas ChromatographyInstrument configuration plan:
Gas chromatograph: equipped with nitrogen phosphorus detector (NPD)a

natural gasIntroduction to Gas Analysis Chromatography:
GC-7890 natural gasThe chromatographic analyzer solves the problems of nitrogen, carbon dioxide, and other pollutants with automatic sampling, automatic injection, automatic data acquisition, and automatic valve cutting in one injectionMethane, ethane, propane, n-butane, isobutane, n-pentane, isopentane, hydrogen sulfideWait for a complete analysis of the gas. This instrument can achievefully automatic operationBy laying pipelines, the tested gas is pumped from the vacuum pump to the gas chromatograph for detection. The detection results are automatically processed by the analysis software, and the entire process is controlled by a microcomputer,the instrumentReduced the workload of analysts and improved work efficiency;rightNatural gas and liquid quality testing providesReliable data. All analyzed data can be retained for staff to reuse.In response to this phenomenon, Shanghai Xuansheng Company has developed a portable fully automatic gas calorific value analyzer to recover losses for LNG users. It can achieve full analysis of nitrogen, methane, ethane, propane and other components in LNG, as well as high calorific value, low calorific value, density, relative density, white number, combustion potential and other parameters.
Characteristics:
◆ With the new generation of high-performance and high stability GC-7890Based on gas chromatography, it operates reliably and stably;
One injection solved the problemNitrogen, carbon dioxideMethane, ethane, propane, n-butane, isobutane, n-pentane, isopentaneComplete analysis of gas; Increase FPD detector can detect simultaneouslynatural gasChineseTrace amounts of hydrogen sulfide, etccontent
Using the application of central cutting technology, multi column parallel series technology, and multi detector parallel series technology, full component analysis is conducted on natural gas, liquefied gas, and other gases.
Instrument technical specifications:
1. Hydrogen flame ionization detector (FID):
Cylindrical collection electrode structure design, quartz nozzle, responsive*
Detection limit: ≤ 8 × 10-12G/s (n-hexadecane/isooctane)
Baseline noise: ≤ 2 × 10-13A
Baseline drift: ≤ 2 × 10-12A/30min
Linear: ≥ 106
Stable time: Ten minutes
2. Thermal conductivity detector (TCD):
Adopting a semi diffusive structure
The power supply adopts constant current control mode
Sensitivity: ≥ 3000mV · ml/mg, high sensitivity ≥ 8000mV · ml/mg
Baseline noise: ≤ 10 μ V.
Baseline drift: ≤ 100 μ V/30min.