Characteristics: In multiple applications, both the beam controller and the electrical control cabinet may require additional cooling

Product Details

1638442265212428 拷贝.jpg


Features:

In multiple applications, both the beam controller and the electrical control cabinet may require additional cooling. The temperature requirement for cooling water is usually between 15-22 ℃, and the accuracy requirement for cooling water is usually ± 1 ℃ or ± 2 ℃. Some laser devices may require ± 0.1 ℃ for their lasers. Laser has certain requirements for cooling water conductivity, corrosiveness, etc., therefore it has high requirements for water quality, and stainless steel is used in the water circuit design. Laser chillers are mainly used in laser marking machines, laser engraving machines, laser welding machines, laser coding machines, laser cutting machines and other laser processing equipment. They accurately control the temperature required by the laser equipment to ensure its normal operation.


Design features of precision chiller:

Large capacity all stainless steel water tank coil evaporator.

Built in high lift stainless steel chilled water pump to ensure the water supply pressure and quality of the host.

Brand high air volume fan, good heat dissipation, low noise.

Optional precision filters, including particulate matter filtration and deionization devices, ensure chilled water quality and extend the service life of laser chillers and laser equipment.

Multiple protection devices: flow switch alarm, water pressure alarm, remote sound and light alarm system,

Equipment operation is safer.

Protection signal output: water flow alarm contact signal output, water level signal contact output, temperature alarm contact signal output, making the operation of laser chillers and laser equipment safer.

Free provision of cooling and heating system solutions

Production oriented enterprises face equipment selection and system design issues when using chillers.
Huaxiang Refrigeration has been focusing on overall solutions for industrial refrigeration systems for 20 years, accumulating rich industry experience,
We provide you with a safe, energy-saving, easy to operate, and unmanned system solution

    1The selection of precision chiller units and supporting equipment is more reasonable, high-quality, and energy-saving

    2Application of self-control technology to achieve fully automatic operation, with simple and convenient operation

    3Based on the overall design scheme, the system runs more safely, reliably, and securely

    4IoT cloud service technology enables remote monitoring of mobile apps

    5The application of a large number of energy-saving technologies makes system operation more energy-efficient and economical

    6Provide SMS pre alert, collect and analyze energy consumption data for operation - selection

Product Parameters


Air cooled scroll chiller parameter sheet selection technical parameter table - air-cooled type
Model/Parameters refrigeration capacity

compressor

input power

chilled water

traffic

water pump

power

water tank

capacity

Freezing water pipe

caliber

cooling air volume

cooling fan

power

refrigerant Overall dimensions
KW Kcal/hr KW m3/h KW L m3/h KW Filling amount - kg L*W*H(mm)
HX-02FW 5.0 2150 1.5 1.0 0.2 30.0 DN-32 2200.0 0.18*1 R22-1.0kg 630*470*800
HX-03FW 7.5 6450 2.2 1.5 0.37 45.0 3100.0 0.19*1 R22-1.5kg 940*555*1060
HX-05FW 12 10750 3.75*1 2.6 0.37 60.0 5400.0 0.19*2 R22-3.0kg 1100*700*1350
HX-06FW 16 13760 4.0*1 3.0 0.37 70.0 6500.0 0.19*2 R22-3.1kg 1100*700*1350
HX-08FW 20 17200 5.5*1 3.5 0.55 80.0 8100.0 0.52*2 R22-4.5kg 1350*740*1430
HX-10FW 25 21500 3.75*2 5.0 0.75 120 DN-40 11000.0 0.52*2 R22-6.0kg 1450*780*1550
HX-12FW 30 25800 4.2*2 6.0 0.75 210 12800.0 0.55*2 R22-7.0kg 1510*780*1600
HX-15FW 37 32250 5.5*2 7.5 1.1 210 15500.0 0.7*2 R22-8.5kg 1600*890*1630
HX-20FW 50 43000 7.5*2 10.0 2.2 270 DN-50 22000.0 0.78*2 R22-11kg 1900*1000*1800
HX-25FW 62 53750 10*2 12.0 2.2 310 25000.0 0.7*3 R22-12kg 2140*1000*1700
HX-30FW 75 64500 7.5*3 15.0 3.0 360 DN-65 31000.0 0.78*3 R22-16kg 2400*1120*1900
HX-40FW 100 86000 7.5*4 20.0 4.0 100 DN-80 42500.0 1.3*3 R22-22kg 2200*1600*2000
HX-50FW 125 107500 10*4 25.0 5.5 100 55000.0 1.3*4 R22-27kg 2400*1600*2100
Note:
1. The cooling capacity is determined based on the following conditions: chilled water inlet temperature of 12 ℃, chilled water outlet temperature of 7 ℃, condenser air inlet temperature of 35 ℃, condenser air outlet temperature of 40 ℃;
2. The above parameter table shows that a cooling capacity of 30HP or more can be equipped with a water tank shell and tube evaporator and a chilled water pump. The size of the water tank volume and the power of the water pump will be noted during the selection process; This parameter specification is for shell and tube evaporator system;
3. Chinese interface digital series control system for control system; Customized as a programmable PLC system, both capable of RS485 communication;
4. The design pressure of the chilled water side for standard models is 1.0Mpa; Container pressurization type (special order model) suitable for design pressure;
5. The client has internal and external wire interfaces, and the flange mode is provided by the customer. The main power supply is 3-phase 380V 50Hz, and the operating power supply is single-phase 220V 50Hz; Please apply in advance when ordering non-standard power supplies;
6. For more detailed parameters, please contact your Huaxiang distributor.

Learn more parameters or click to consult