Welcome Customer !

Membership

Help

Beijing Zhongke Ke Er Instrument Co., Ltd
Custom manufacturer

Main Products:

mechb2b>Products

Beijing Zhongke Ke Er Instrument Co., Ltd

  • E-mail

  • Phone

  • Address

    7F, Building E, Huating Jiayuan, No. 6 North Fourth Ring Middle Road, Chaoyang District, Beijing

Contact Now

4P Ⅱ and 6P Ⅱ waterproof multi parameter measuring instruments

NegotiableUpdate on 05/05
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

4P Ⅱ and 6P Ⅱ waterproof multi parameter measuring instruments

Product Details

4P Ⅱ and 6P Ⅱ waterproof multi parameter measuring instruments
Model: 19401-12,22
characteristic:

Place of Origin:

America

Instrument Introduction:

  • IP67 Valox casing - can be submerged up to 3 feet underwater.

  • The four digit LCD display can display up to 9999us/ppm.

  • 19401-22 can also measure pH and redox potential.

These measuring instruments are simple and convenient to use, simply add the sample to the built-in sample pool of the machine, press the measurement button, and read directly.

The automatic range change function can automatically select 5 conductivity or total solution range.

The factory calibrated measuring instrument stores the conductivity of NaCl, 442, and KCl standards to the total solution solid conversion curve. You can also calibrate with your own measurement values.

The automatic temperature compensation system with an adjustable temperature coefficient of up to 9.99% can provide accurate measurement results. Can store and call up to 100 sets for time and

The measurement results with the date as the title. The non-volatile storage function can retain all data and can be downloaded via infrared using uDock attachments.

19401-12 (4P II measuring instrument)

Conductivity:0to9.9910to99.99100to999.91000to9999uS

Range: 10.00to200mS(Automatic range change)

Resistance:1to30kΩ

PH:0to14.00pH

Redox potential:±999mV

Temperature:32to160℉(0to71℃)

Conductivity:0.010.11uS0.01mS

Total solution:0.010.11ppm0.01ppt

Resistance:0.01,0.1 kΩ0.01 MΩ

PH:0.01pH

Redox potential:1mV

Temperature:0.1℉(0.1℃)

Conductivity:± of reading1%

Total solution:± of reading1%

Resistance:± of reading1%

PH:±0.01pH

Redox potential:±1mV

Temperature:±0.1℉(±0.1℃)

19401-22 (6P II measuring instrument)

Conductivity:0to9.9910to99.99100to999.91000to9999ppm

Range:10.00to200ppt

Resistance:1 to 30k Ω

PH:0 to 14.00pH

Redox potential:±999mV

Temperature:32 to 160 ℉ (0 to 71 ℃)

Conductivity:0.01,0.1,1uS;0.01mS

Total solution:0.01,0.1,1ppm; 0.01ppt

Resistance:0.01,0.1 kΩ;0.01 MΩ

PH:0.01pH

Redox potential:1mV

Temperature:0.1℉(0.1℃)

Conductivity:± 1% of the reading

Total solution:± 1% of the reading

Resistance:± 1% of the reading

PH:±0.01pH

Redox potential:±1mV

Temperature:±0.1℉(±0.1℃)