Price of water flow meterThe water flow meter provided by the supplier is based on the principle of torque balance and belongs to the velocity flow meter. It has the characteristics of simple structure, lightweight, high accuracy, good reproducibility, sensitive response, and easy installation, maintenance, and use. It is widely used in industries such as petroleum, chemical, metallurgy, water supply, and papermaking, and is an ideal instrument for flow measurement and energy conservation.
What are the usage and adjustment items of a water flow meter?
When using, the tested liquid should be kept clean and free of impurities such as fibers and particles.
At the beginning of use, the sensor should be slowly filled with liquid before opening the outlet valve. It is strictly prohibited for the sensor to be impacted by high-speed fluid when it is in a liquid free state.
3. The maintenance cycle of the water flow meter is generally six months. During maintenance and cleaning, please be careful not to damage the parts inside the measuring chamber, especially the impeller. Please pay attention to the position relationship between the guide components and the impeller during assembly.
When the sensor is not in use, the internal liquid should be cleaned and protective covers should be added at both ends of the sensor to prevent dust and dirt from entering, and then stored in a dry place.
5. The filter used should be cleaned regularly. When not in use, the liquid inside should be cleaned. Like the sensor, it should be added with a dust boot and stored in a dry place.
6. Before installing the water flow meter, connect it to the display instrument or oscilloscope, turn on the power, blow or manually turn the impeller to quickly rotate and observe whether there is a display. When there is a display, install the sensor. If there is no display, check the relevant parts and eliminate the fault.