Welcome Customer !

Membership

Help

Suzhou Yidete Machinery Co., Ltd
Custom manufacturer

Main Products:

mechb2b>Article

Suzhou Yidete Machinery Co., Ltd

  • E-mail

    etite@sina.com

  • Phone

    18939778618

  • Address

    Building 7, No. 38 Beiguandu Road, Wuzhong District, Suzhou City

Contact Now
Selection and operation process of oil type mold temperature machine
Date: 2022-03-10Read: 16
  Oil-type mold temperature controllerAs the name suggests, it is a mold temperature machine that uses thermal oil as a heat transfer medium. The oil type mold temperature machine itself is equipped with a storage tank. During operation, the heat transfer oil enters the system from the storage tank and is pumped into the mold or other temperature controlled equipment through a circulation pump. After the heat transfer oil comes out of the temperature controlled equipment, it returns to the system and repeats the process. The heat transfer oil is heated by the heater, and when the medium temperature detected by the temperature sensing probe reaches the set value, the heater stops working. When the temperature is below the set value, the heater starts working, and when the temperature reaches the set value, it stops working again. This cycle repeats itself.
Key points for choosing an oil type mold temperature machine:
1. Computer touch control, simple and easy to understand operation;
2. Microcomputer dual group P.I.D temperature control table, touch sensitive internal storage, automatic calculation;
3. Safety protection and fault indication system;
4. Long service life of components;
5. Fast temperature rise and fall speed, precise and stable temperature;
6. The high-power heating design is suitable for use in different temperature controlled places, with significant energy-saving effects;
7. Stainless steel one-piece molding, small tube donation, evenly cooked;
8. Automatic exhaust function upon startup;
9. Mold return oil temperature detection table.
operating procedure
1、 Pre start inspection
1. Check if the surroundings are clean and free of debris, and verify if the power supply, heater, controller, pressure gauge, pump, etc. are functioning properly.
2. Check if the oil level in the expansion tank is above the 1/2-3/5 level, and if the level sensor is functioning properly.
3. Connect the power supply to the control cabinet, check if the voltage is normal, and verify if the indicator lights and various display instruments are functioning properly.
2、 Start up
1. Start the heat transfer oil circulation pump and circulate it normally for about 0.5 hours to stabilize the pressure;
2. Press the heating start button and observe if the heating is normal;
3、 Shutdown operation
1. Normal shutdown
① Gradually reduce the temperature and stop heating;
② Stop the operation of the heat transfer oil circulation pump when the temperature of the heat transfer oil drops below 70 ℃;
③ Turn off the main power and keep a handover record.
2. If an emergency shutdown occurs due to an urgent situation, the heating tube should be quickly turned off to allow the heat transfer oil to cool naturally and prevent overheating.