Multimeter

NegotiableUpdate on 03/18
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Can replace desktop electric meters br〉〈br〉〈br〉0.04% DC and 0.2% AC Z Excellent accuracy br〉60, 000 resolution (4 5/6 bits) br〉10KHz Bandwidth (Z is large) br〉
Product Details

Specifications (23℃±5)

The accuracy listed below is for a single channel(通道1 Or channel2).When dual channels are used simultaneously,There are other specifications available. Please refer to the attached dual channel specification table for detailed data. The accuracy in the table also includes zeroing(relative)value. Its expression is ±%Read value ±digit.

DC voltage:(input impedance: 10M) (Overload protection AC power1000V)

scope

resolution

accuracy
60.000mV 0.001mV ±0.2%±9dgts1
600.00mV 0.01mV ±0.04%±6dgts
6.0000V 0.0001V ±0.04%±6dgts
60.000V

0.001V

±0.04%±6dgts
600.00V 0.01V ±0.04%±6dgts
1000.0V 0.1V ±0.08%±6dgts

AC voltage: ACVor AC mVAccuracy is limited to 20Hz~10KHzscope5%-100%,input impedance10M ,Overload protection AC current 1000V.Accuracy is limited to the channel only1.When dual channel measurements are performed simultaneously,There are other accuracy specifications available. Please refer to the dual channel specification table for this section.

scope

(ACV)

resolution

accuracy

(50/60Hz)

accuracy

(45Hz - 1KHz)

accuracy

(20Hz - 45Hz)

accuracy

(1KHz - 10KHz)

60.000mV 0.001mV ±0.2%±40dgts ±0.6%±40dgts ±1.6%±50dgts ±4%±40dgts
600.00mV 0.01mV ±0.2%±40dgts ±0.6%±40dgts ±1.6%±50dgts ±2%±40dgts
6.0000V 0.0001V ±0.2%±40dgts ±0.6%±40dgts ±1.6%±50dgts ±2%±40dgts
60.000V 0.001V ±0.2%±40dgts

±0.6%±40dgts 

±1.6%±50dgts ±2%±40dgts
600.00V(0-400V) 0.01V ±0.2%±40dgts ±1.0%±40dgts ±1.6%±50dgts ±9%±40dgts
600.00V(400-600V) 0.01V ±0.2%±40dgts ±1.0%±40dgts ±1.6%±50dgts Not Specified

1000.0V (0-400V)

0.1V ±0.2%±40dgts

±4%±60dgts

±1.6%±50dgts ±4%±80dgts
1000.0V (400-1000V) 0.1V ±0.2%±40dgts (45Hz - 400Hz)±4%±60dgts ±1.6%±50dgts Not Specified

 

Supplementary specification table for dual channel specifications(DC - 400Hz):  Dual channel simultaneous measurement,The increase in accuracy in the following table must be included in the previously listed items:

  ACV (Ch2) DCV (Ch2) ACA (Ch2) DCA (Ch2)
ACV (Ch1)

±2%±( V1 - V2 )* 200 PPM (Ch1, Ch2)

±0.9%±(V1 - V2) * 20 PPM (Ch1, Ch2)
±0.2mA / V(MA,Ch2)
±2MA / V (mA,Ch2)
±0.4mA / V (A, Ch2)
±4mV / A (mV, Ch1)
±9mV / A (V, Ch1)
±0.5% (Ch1, Ch2)
DCV (Ch1) ±0.9%±(V1 - V2) * 20 PPM(Ch1, Ch2) ±0.5% (Ch1,Ch2) ±0.5% (Ch1, Ch2) ±0.5% (Ch1, Ch2)

direct current: (10Aend From one 20ampere,rapid response,High energy fuse protection,MAand mAThe terminal is based on 1ampere,rapid response,High energy fuse protection)

scope

resolution

accuracy

600.00MA

0.01MA ±0.4%±20dgts
6000.0MA

0.1MA

±0.2%±20dgts
60.000mA 0.001mA ±0.4%±20dgts
600.00mA 0.01mA

±0.2%±20dgts

1.0000A 0.0001A ±0.2%±20dgts
10.000A1 0.001A ±0.6%±20dgts

alternating current: (Accuracy limited to single channel45Hz - 10KHzof 5%-100%,True RMSwithin the scope of,10Aend From one 20ampere,rapid response,High energy fuse protection,MAand mAThe terminal is based on 1ampere,rapid response,High energy fuse protection)

scope(ACA) resolution accuracy (50/60Hz) accuracy (45Hz - 1KHz) Accuracy(20Hz - 45Hz)

accuracy (1KHz -10KHz)

600.00MA 0.01MA ±0.6%±40dgts ±0.8%±40dgts ±2%±20dgts ±4%±20dgts
6000.0MA 0.1MA ±0.6%±40dgts ±0.8%±40dgts ±2%±20dgts ±4%±20dgts
60.000mA 0.001mA ±0.6%±40dgts ±0.8%±40dgts ±2%±20dgts ±0.9%±20dgts
600.00mA 0.01mA ±0.6%±40dgts ±0.8%±40dgts ±2%±20dgts ±0.9%±20dgts
1.0000A 0.0001A ±0.6%±40dgts ±0.8%±40dgts ±2%±20dgts ±2.5%20dgts
10.000A1 0.001A

±0.9%±40dgts

±0.9%±40dgts ±3.9%±20dgts ±2.5%20dgts

resistance:(Ω) (Overload protection AC current1000V)

scope resolution accuracy
999.99Ω 0.01Ω ±0.25%±9dgts
9.9999KΩ 0.0001KΩ ±0.15%±6dgts
99.999KΩ 0.001KΩ

±0.15%±6dgts

999.99KΩ 0.01KΩ ±0.15%±6dgts
9.9999MΩ 0.0001MΩ ±0.3%±9dgts
40.000MΩ

0.001MΩ

±1.5%±9dgts

capacitance:( , Automatic range)

scope resolution accuracy
60.00nF 0.01nF ±1.2%±8dgts
600.0nF 0.1nF ±2.5%±8dgts
6.000MF 0.001MF ±2.5%±8dgts
60.00MF 0.01MF ±3.0%±8dgts
600.0MF 0.1MF ±5.0%±8dgts

Conductivity test:( ,Open voltage approximately 3V)(Overload protection AC current1000V)

scope resolution Beeper
999.99Ω 0.01Ω < 40Ω approx

Diode testing:(Open voltage approximately 3V) (Overload protection AC current1000V)

scope resolution accuracy Current short circuit
3.0000V 0.0001V ±2%±5dgts 0.8 mA ( Approximately)

frequency:(TTL)(Overload protection AC current1000V)

scope (automatic) resolution accuracy
1.000Hz -2MHz 0.0001Hz- 0.0001MHz ±0.005%±4dgts

Wave width: (%, TTL, 1Hz - 600KHz) (Overload protection AC current1000V)

scope resolution accuracy
0.001% - 9.999% 0.001% ±30d/KHz±30dgts
10.00% - 100.00% 0.01% ±3d/KHz±3dgts

General Specifications

battery: 9V
display: 5 + 5bit LCDWith simulated line diagram
range selection: automatic and manual
Overload warning: OL
current consumption: 4 mA (approximately)
Voltage shortage warning
Operating Temperature: -10.C to 50.C
Operating Humidity:

less than 85% (relative humidity)

height: up to 2000M
Storage temperature: -20.C to 60.C
storage humidity: less than 75% (relative humidity)
size (length, width, height): 207mm(L) x 101mm (W) x 47mm (H)8.15' (L) x 4' (W) x 1.85' (H)
weight: 430gram / 15.2ounce (Contains battery)
accessories:
Instruction Manual x 1
9Vbattery x 1
Purchase accessories:
Choose 1:801 A1: sheath

Option 2:801 A2:RS-232C Adapter+computer application software