E-mail
victor@china-victor.com
- Phone
-
Address
16th Floor, Block D, Tairan Building, Tairan Sixth Road, Futian District, Shenzhen
Shenzhen Yisheng Shengli Technology Co., Ltd
victor@china-victor.com
16th Floor, Block D, Tairan Building, Tairan Sixth Road, Futian District, Shenzhen

| Product model: VICTOR 9001 | |
|
Product Name:Wireless high and low voltage meter |
|
|
Function
|
High and low voltage testing, frequency testing, and electrical verification
|
|
Power supply
|
Collector: DC 3.7V rechargeable lithium battery, can work continuously for about 20 hours when fully charged
Receiver: DC 8.4V rechargeable lithium battery, can work continuously for about 8 hours when fully charged |
|
measurement method
|
Test voltage: Contact test, bare wire contact test below 65kV;
Electrical testing: non-contact electrical testing, non-contact testing of bare wires exceeding 65kV |
|
transmission method
|
433MHz wireless transmission
|
|
transmission distance
|
The straight-line distance is about 100m
|
|
display mode
|
3.5-inch true color LCD display
|
|
Hanging wire diameter
|
70mm (when using a metal probe hook)
|
|
Pressure measurement range
|
Voltage: 0-65kV (50Hz)
|
|
Frequency: 45.0Hz to 55.0Hz
|
|
|
resolution
|
1V(100V~2000V)
|
|
0.01kV(2.00kV~20.00kV)
|
|
|
0.1kV(20.0kV~65.0kV)
|
|
|
0.1Hz
|
|
|
Voltage accuracy
|
± 5% (0.1kV~65.0kV, 23 ℃ -25 ℃, below 70% Rh)
|
|
frequency accuracy
|
±2Hz(0.1kV~65.0kV)
|
|
Insulation rod length
|
Connect the total length of 4.2m (0.9m for 4 sections and 0.6m for 1 section)
|
|
Ground wire length
|
7m
|
|
data storage
|
9999 sets
|
|
sampling rate
|
2 times per second
|
|
Instrument size
|
Collector: length, width, and thickness 275mm × 105mm × 52mm
Receiver: length, width, and thickness 250mm x 100mm x 45mm |
|
line voltage
|
Bare wires below 65kV can be directly contacted for measurement, and the metal hook of the collector can stably hook onto the bare wire; When conducting electrical testing, bare wires exceeding 65KV should not be tested in contact with bare wires exceeding kV, but can be tested with insulated wires of 110kV.
|
|
data retention
|
Press in data measurement modeHOLDPress the key to hold the data, then press againHOLDKey Cancel Keep
|
|
Exit function
|
pressESCPress the key to exit the current function interface and return to the higher-level directory
|
|
Data retrieval
|
After entering the data retrieval mode,arrowKey to browse the stored data
|
|
No signal indication
|
Dynamically display the "----" symbol when the receiver does not receive the transmission signal
|
|
Auto Shutdown
|
After about 15 minutes of startup, the instrument panel automatically shuts down to reduce battery consumption
|
|
battery voltage
|
When the battery voltage is too low, the low battery voltage symbol is displayed to remind charging
|
|
Instrument quality
|
Collector: 230g (including battery)
Receiver: 410g (including battery) Total weight: 3.5kg (including insulation rod, grounding wire, and battery) |
|
Working temperature and humidity
|
-10℃~40℃; Below 70% Rh
|
|
Storage temperature and humidity
|
-10℃~60℃; Below 70% Rh
|
|
radio interference
|
No interference from 433MHz same frequency signals
|
|
Dielectric Strength
|
Insulated pole: AC 110kV/rms (all insulated poles are connected between both ends)
Collector: 2000V/rms (between the two ends of the casing) Receiver: 2000V/rms (front and rear ends of the casing) |
|
Structure
|
Collector anti drip type II
|