WRN2-230 assembly thermocouple

NegotiableUpdate on 02/03
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Kangtai brand assembled thermocouple: WRN2-230 assembled thermocouple, WRN-230 assembled thermocouple, nickel chromium nickel silicon thermocouple

Product Details

WRN2-230 assembly thermocoupleProduct Introduction

Industrial assembled thermocouples, as a type of temperature sensor, are usually used in conjunction with display instruments, recording instruments, and electronic regulators. Prefabricated thermocouples can directly measure the surface temperature of liquid vapor and gas media, as well as solids, ranging from 0 ℃ to 1800 ℃ in various production processes. According to regulations, our company produces prefabricated thermocouples that comply with IEC standard graduation numbers, such as Platinum Rhodium 30-Platinum Rhodium 6, Platinum Rhodium 10 Platinum, Nickel Chromium Nickel Silicon, Nickel Chromium Copper, etc. The assembly of thermocouples usually consists of main components such as temperature sensing elements, installation fixtures, and junction boxes.

WRN2-230 assembly thermocoupleProduct Details

WRN-230

single pieceKType temperature measuring component, straight sleeve, waterproof junction box assembly thermocouple

WRN2-230

Double supportKType temperature measuring component, straight sleeve, waterproof junction box assembly thermocouple

Measurement range and allowable error range of thermocouple assembly:

Thermocouple category

Code name

Dividing number

Measurement range

Basic error limit

Nickel chromium constantan

WRK

E

0-800℃

±0.75%t

Nickel chromium nickel silicon

WRN

K

0-1300℃

±0.75%t

铂铑 13 -铂

WRB

R

0-1600℃

±0.25%t

铂铑 10 -铂

WRP

S

0-1600℃

±0.25%t

Platinum rhodium 30- Platinum rhodium 6

WRR

B

0-1800℃

±0.25%t

Note: t is the measured temperature value of the temperature sensing element (℃)

Thermocouple time constant

Thermal inertia level

Time constant (seconds)

Thermal inertia level

Time constant (seconds)

90-180

10-30

30-90

<10

Thermocouple nominal pressure: generally refers to the static external pressure that the protective tube can withstand and rupture at operating temperature.
Thermocouple * small insertion depth: should not be less than 8-10 times the outer diameter of its protective sleeve (except for special products)
Insulation resistance: When the ambient air temperature is 15-35 ℃ and the relative humidity is less than 80%, the insulation resistance is ≥ 5 megohms (voltage 100V). Thermocouples with splash proof junction boxes have an insulation resistance of ≥ 0.5 megohms (voltage 100V) when the relative temperature is 93 ± 3 ℃
Insulation resistance at high temperatures: For thermocouples, the insulation resistance (per meter) between the hot electrode (including double branch) and the protective tube, as well as between the double branch hot electrodes, should be greater than the values specified in the table below.

Designated long-term use temperature (℃)

Test temperature (℃)

Insulation resistance value (Ω)

≥600

600

72000

≥ 800

800

25000

≥1000

1000

5000