◆ Model:WR□□□□01□□□□
◆ Parameters:Simplified Armor Core, WR □□□□□ 01 □□□□□, WZ □□□□ 01 □□□□□ 、
structural principle
The WR series of ordinary and explosion-proof armored thermal resistors/thermocouples have the advantages of being slender, easy to bend, fast in thermal response time, vibration resistance, temperature resistance, pressure resistance, and durability. It can be used for direct measurement or as an inner core component for prefabricated thermocouples and thermal resistors, replacing traditional prefabricated ones. Especially suitable for installation in narrow, curved pipelines that require quick response, and special temperature measurement situations. Armored platinum resistance thermometers can be used to measure temperatures within the range of -200 to+500 ℃. The product is suitable for use in places with explosive gases within the temperature range of dIIBT4 and dIICT5. Compliant with IEC60079 standard and GB3836 standard.
Thermistor measures temperature by utilizing the characteristic that the resistance of a substance changes with temperature. The heated part (temperature sensing element) of a thermal resistor is uniformly wound around a skeleton made of insulating material with thin metal wires. When there is a temperature gradient in the measured medium, the measured temperature is the average temperature in the medium within the range of the temperature sensing element.
The working principle of a thermocouple is to weld two conductors or semiconductors with different compositions at both ends to form a closed circuit. Due to the different number of electrons carried by two different metals, when there is a temperature difference between the hot and cold ends of two conductors, a discharge phenomenon from high potential to low potential occurs, resulting in the formation of current in the circuit. The larger the temperature difference, the greater the current. This phenomenon is called thermoelectric effect, also known as Seebeck effect. Thermocouples work by utilizing this effect. The direct temperature measurement end is called the measurement node (or hot end), and the wiring end is called the reference node (or cold end).
Product Selection
| WR/WZ | thermal resistor/thermocouple/Temperature Transmitter | Registered model | ||||||||||||||||||||||||||||
| | Z | Thermal resistance(RTD) | sensor type | |||||||||||||||||||||||||||
| R | Thermocouple(TC) | |||||||||||||||||||||||||||||
| | P | Platinum thermistor:Pt | Division number, scope of application, accuracy level, tolerance | |||||||||||||||||||||||||||
| C | Copper thermistor:Cu50 Cu-RTDScope of application:-50℃~+ | |||||||||||||||||||||||||||||
| S | platinum-rhodium10-Platinum thermocouplePT10%RH-PtScope of application:0~1100℃ Accuracy level, allowable deviation Δt(℃): Grade I ± (±) | |||||||||||||||||||||||||||||
| B | platinum-rhodium30-platinum-rhodium6thermocouplePt30%Rh-Pt6%RhScope of application:0~1600℃ Accuracy level, allowable deviation Δt(℃): Grade I ± (±) | |||||||||||||||||||||||||||||
| E | Nickel cadmium-Copper nickel thermocouple NiCr-CuNi Scope of application:0~600℃ Accuracy level, allowable deviation Δt(℃): Grade I ± (±) | |||||||||||||||||||||||||||||
| K | Nickel cadmium-Nickel silicon thermocouple NiCr-NiAi Scope of application:0~800℃ Accuracy level, allowable deviation Δt(℃): Grade I ± (±) | |||||||||||||||||||||||||||||
| R | platinum-rhodium13-Platinum thermocouple Pt13%Rh-Pt Scope of application:0~1200℃ Accuracy level, allowable deviation Δt(℃): Grade I ± (±) | |||||||||||||||||||||||||||||
| J | iron-Copper nickel thermocouple Fe-CuNi Scope of application:0~500℃ Accuracy level, allowable deviation Δt(℃): Grade I ± (±) | |||||||||||||||||||||||||||||
| T | copper-Copper nickel thermocouple Cu-CuNi Scope of application:-400~300℃ Accuracy level, allowable deviation Δt(℃): Grade I ± (±) | |||||||||||||||||||||||||||||
| | K | Armored type thermistor or thermocouple, no transmission output | Integrated and split type temperature transmitter | |||||||||||||||||||||||||||
| A | Equipped with a regular integrated transmission module and output two-wire system4~20mA DC | |||||||||||||||||||||||||||||
| B | Equipped with integrated intelligent temperature transmission module, isolated type, two-wire system4~20mA DC HART | |||||||||||||||||||||||||||||
| C | Integrated form,Atype+sceneLEDdigital display | |||||||||||||||||||||||||||||
| D | Integrated form,Btype+sceneLEDdigital display | |||||||||||||||||||||||||||||
| E | Split installation type, on-siteLEDDigital display, two-wire system4~20mA DC | |||||||||||||||||||||||||||||
| F | Split installation type, on-siteLEDDigital display, two-wire isolated output4~20mA DC HART | |||||||||||||||||||||||||||||
| | 1 | Single component | 2 | Dual component | 3 | Three components | N | NSupporting components | Number of temperature sensing elements | |||||||||||||||||||||
| | 1 | Normal pressure, or ≤0.2Mpa | 5 | PN11Mpa;Class | pressure rating | |||||||||||||||||||||||||
| 2 | PN2.5Mpa;Class | 6 | PN15Mpa;Class | |||||||||||||||||||||||||||
| 3 | PN5.0Mpa;Class | 7 | PN26Mpa;Class | |||||||||||||||||||||||||||
| 4 | PN6.4Mpa;Class | 8 | PN32Mpa;Class | |||||||||||||||||||||||||||
| | 01 | Simple armored core (with magnetic wire board and spring) | 14 | Clamp type pipe wall measurement type (with thermal block) | Product Type | |||||||||||||||||||||||||
| 02 | Non fixed device type (Φ)12Or Φ protective tube) | 15 | Hot sleeve thermocouple armored extension type | |||||||||||||||||||||||||||
| 03 | Fixed bolt type Protective tube (Φ)12、Φ16) | 16 | Fixed bolt cone-shaped protective tube armor element extension type | |||||||||||||||||||||||||||
| 04 | Activity flange type | 17 | High wear resistant type (two section type) | |||||||||||||||||||||||||||
| 05 | Fixed flange type | 18 | High wear resistant type (single section type) | |||||||||||||||||||||||||||
| 06 | Fixed bolt type with conical protective tube | 19 | High temperature, high wear-resistant protective tube thermocouple | |||||||||||||||||||||||||||
| 07 | Straight pipe connector type (two section type) | 20 | High temperature salt bath furnace thermocouple | |||||||||||||||||||||||||||
| 08 | Flexible tube connector type (two section type) | 21 | Wear resistant high-temperature thermocouple for cement rotary kiln | |||||||||||||||||||||||||||
| 09 | Fixed thread type (two section type) | 22 | Rotary kiln flue type high alumina, corundum | |||||||||||||||||||||||||||
| 10 | Hot sleeve deep blind hole protection tube type (two section type) | 23 | Corrosion resistance(PTFE)Type thermocouple, thermistor | |||||||||||||||||||||||||||
| 11 | Welded cone-shaped blind hole protective tube type (two sections) | 24 | Wear resistant thermocouple with shut-off valve and thermal resistance | |||||||||||||||||||||||||||
| 12 | Large diameter protective pipe type for flue and air duct | 25 | Multi point armored thermocouple with thermal resistance, capable of10point | |||||||||||||||||||||||||||
| 13 | Corrosion resistant type for coal powder silo (low-temperature alloy corrosion resistant) | 26 | | |||||||||||||||||||||||||||
| | A | M27×2 | E | G1“ | I | M18×1.5 | M | DN40(11/2“)flange | Process Connection | |||||||||||||||||||||
| B | M20×1.5 | F | 1/2“NPT | J | DN15(1/2')flange | P | DN50(2“)flange | |||||||||||||||||||||||
| C | G1/2“ | G | 3/4“NPT | K | DN20(3/4')flange | Q | DN80(3“)flange | |||||||||||||||||||||||
| D | G3/4“ | H | 1“NPT | L | DN25(1')Flanges | N | user | |||||||||||||||||||||||
| | B | 304 | S9 | 321 | Ni | Ni9990 | F46 | FEP | Material of protective tube | |||||||||||||||||||||
| C | | NB | 347 | Ti | TA(1-3) | A8 | High lead content | |||||||||||||||||||||||
| D | 310S | N6 | Inconel600 | G3 | GH3030 | A9 | Jadeite qualityAl2O3 | |||||||||||||||||||||||
| E | 316 | HB | Hasloy B | G9 | CH3039 | SN | silicon nitrideSi3N4 | |||||||||||||||||||||||
| F | | HC | Hasloy C | SO | quartzSiO2 | SC | silicon carbideSiC | |||||||||||||||||||||||
| MT | 316Ti | | Monel k500 | F4 | PTFE | MS | Molybdenum disilicideMoSi | |||||||||||||||||||||||
| W | Other special materials | | ||||||||||||||||||||||||||||
| | O | Ordinary waterproof type | D | flameproof typeExdIICT1~T6 | security level | |||||||||||||||||||||||||
| | 100 | 250 | 400 | 600 | 900 | 1500 | 3000 | Nominal lengthmm (No longer within the nominal length, can fill in the required length) | ||||||||||||||||||||||
| 150 | 300 | 500 | 750 | 1000 | 2000 | 3500 | ||||||||||||||||||||||||
| 200 | 350 | 550 | 800 | 1200 | 2500 | Length requiredmm | ||||||||||||||||||||||||
| ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | | ||||||||||||||||||||
| WR | S | A | 1 | 1 | 18 | A | B | O | 1200 | Example of Selection | ||||||||||||||||||||
| WRThermal resistance transmitter; platinum-rhodium10-Platinum thermocouple,PT10%RH-PtThe scope of application is0~ | ||||||||||||||||||||||||||||||
◆ Parameters:Detachable, WR □□□□□ 08 □□□□, WZ □□□□ 08 □□□□ 、
◆ Model:WR、WZ-5
◆ Parameters:Fixed bolt type, WR □□□□□ 03 □□□□, WZ □□□□ 03 □□□□