WR, WZ-4 thermocouple, thermistor

NegotiableUpdate on 04/26
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The WR series of ordinary and explosion-proof armored thermal resistors/thermocouples have the advantages of being slender, easy to bend, fast in thermal response time, vibration resistance, temperature resistance, pressure resistance, and durability.

Product Details

◆ Model:WR、WZ-4
◆ Parameters:Active flange type, WR □□□□□ 04 □□□□, WZ □□□□ 04 □□□□ 、


structural principle

The WR series of ordinary and explosion-proof armored thermal resistors/thermocouples have the advantages of being slender, easy to bend, fast in thermal response time, vibration resistance, temperature resistance, pressure resistance, and durability. It can be used for direct measurement or as an inner core component for prefabricated thermocouples and thermal resistors, replacing traditional prefabricated ones. Especially suitable for installation in narrow, curved pipelines that require quick response, and special temperature measurement situations. Armored platinum resistance thermometers can be used to measure temperatures within the range of -200 to+500 ℃. The product is suitable for use in places with explosive gases within the temperature range of dIIBT4 and dIICT5. Compliant with IEC60079 standard and GB3836 standard.

Thermistor measures temperature by utilizing the characteristic that the resistance of a substance changes with temperature. The heated part (temperature sensing element) of a thermal resistor is uniformly wound around a skeleton made of insulating material with thin metal wires. When there is a temperature gradient in the measured medium, the measured temperature is the average temperature in the medium within the range of the temperature sensing element.
The working principle of a thermocouple is to weld two conductors or semiconductors with different compositions at both ends to form a closed circuit. Due to the different number of electrons carried by two different metals, when there is a temperature difference between the hot and cold ends of two conductors, a discharge phenomenon from high potential to low potential occurs, resulting in the formation of current in the circuit. The larger the temperature difference, the greater the current. This phenomenon is called thermoelectric effect, also known as Seebeck effect. Thermocouples work by utilizing this effect. The direct temperature measurement end is called the measurement node (or hot end), and the wiring end is called the reference node (or cold end).

Product Selection

WR/WZ

thermal resistor/thermocouple/Temperature Transmitter

Registered model

 

Z

Thermal resistance(RTD

sensor type

R

Thermocouple(TC

 

P

Platinum thermistor:Pt100 Pt-RTDScope of application:-200℃~+500 Accuracy level, tolerance (℃):AGrade ±(0.15+0.002|t|BGrade ±(0.15+0.002|t|

Division number, scope of application, accuracy level, tolerance

C

Copper thermistor:Cu50 Cu-RTDScope of application:-50℃~+150 Accuracy level, tolerance (℃): ±(0.30+0.005|t|

S

platinum-rhodium10-Platinum thermocouplePT10%RH-PtScope of application:01100 Accuracy level, allowable deviation Δt(℃): Grade I ± (±)1.0)Level II ± (±)1.5

B

platinum-rhodium30-platinum-rhodium6thermocouplePt30%Rh-Pt6%RhScope of application:01600 Accuracy level, allowable deviation Δt(℃): Grade I ± (±)1.0)Level II ± (±)1.5

E

Nickel cadmium-Copper nickel thermocouple NiCr-CuNi Scope of application:0600 Accuracy level, allowable deviation Δt(℃): Grade I ± (±)1.5)Level II ± (±)2.5

K

Nickel cadmium-Nickel silicon thermocouple NiCr-NiAi Scope of application:0800 Accuracy level, allowable deviation Δt(℃): Grade I ± (±)1.5)Level II ± (±)2.5

R

platinum-rhodium13-Platinum thermocouple Pt13%Rh-Pt Scope of application:01200 Accuracy level, allowable deviation Δt(℃): Grade I ± (±)1.0)Level II ± (±)1.5

J

iron-Copper nickel thermocouple Fe-CuNi Scope of application:0500 Accuracy level, allowable deviation Δt(℃): Grade I ± (±)1.0)Level II ± (±)2.5

T

copper-Copper nickel thermocouple Cu-CuNi Scope of application:-400300 Accuracy level, allowable deviation Δt(℃): Grade I ± (±)0.5)Level II ± (±)1.0

 

K

Armored type thermistor or thermocouple, no transmission output

Integrated and split type temperature transmitter

A

Equipped with a regular integrated transmission module and output two-wire system420mA DC

B

Equipped with integrated intelligent temperature transmission module, isolated type, two-wire system420mA DC HART

C

Integrated form,Atype+sceneLEDdigital display

D

Integrated form,Btype+sceneLEDdigital display

E

Split installation type, on-siteLEDDigital display, two-wire system420mA DC

F

Split installation type, on-siteLEDDigital display, two-wire isolated output420mA DC HART

 

1

Single component

2

Dual component

3

Three components

N

NSupporting components

Number of temperature sensing elements

 

1

Normal pressure, or ≤0.2Mpa

5

PN11MpaClass600LBANSI

pressure rating

2

PN2.5MpaClass150LBANSI

6

PN15MpaClass900LBANSI

3

PN5.0MpaClass300LBANSI

7

PN26MpaClass1500LBANSI

4

PN6.4MpaClass400LBANSI

8

PN32MpaClass2500LBANSI

 

01

Simple armored core (with magnetic wire board and spring)

14

Clamp type pipe wall measurement type (with thermal block)

Product Type

02

Non fixed device type (Φ)12Or Φ protective tube)

15

Hot sleeve thermocouple armored extension type

03

Fixed bolt type Protective tube (Φ)12、Φ16

16

Fixed bolt cone-shaped protective tube armor element extension type

04

Activity flange type

17

High wear resistant type (two section type)

05

Fixed flange type

18

High wear resistant type (single section type)

06

Fixed bolt type with conical protective tube

19

High temperature, high wear-resistant protective tube thermocouple

07

Straight pipe connector type (two section type)

20

High temperature salt bath furnace thermocouple

08

Flexible tube connector type (two section type)

21

Wear resistant high-temperature thermocouple for cement rotary kiln

09

Fixed thread type (two section type)

22

Rotary kiln flue type high alumina, corundum

10

Hot sleeve deep blind hole protection tube type (two section type)

23

Corrosion resistance(PTFE)Type thermocouple, thermistor

11

Welded cone-shaped blind hole protective tube type (two sections)

24

Wear resistant thermocouple with shut-off valve and thermal resistance

12

Large diameter protective pipe type for flue and air duct

25

Multi point armored thermocouple with thermal resistance, capable of10point

13

Corrosion resistant type for coal powder silo (low-temperature alloy corrosion resistant)

26

3AHygiene standards, food type thermocouples

 

A

M27×2

E

G1

I

M18×1.5

M

DN40(11/2flange

Process Connection

B

M20×1.5

F

1/2NPT

J

DN15(1/2')flange

P

DN50(2flange

C

G1/2

G

3/4NPT

K

DN20(3/4')flange

Q

DN80(3flange

D

G3/4

H

1NPT

L

DN25(1')Flanges

N

user

 

B

304

S9

321

Ni

Ni9990

F46

FEP

Material of protective tube

C

304L

NB

347

Ti

TA(1-3)

A8

High lead content

D

310S

N6

Inconel600

G3

GH3030

A9

Jadeite qualityAl2O3

E

316

HB

Hasloy B

G9

CH3039

SN

silicon nitrideSi3N4

F

316L

HC

Hasloy C

SO

quartzSiO2

SC

silicon carbideSiC

MT

316Ti

5M

Monel k500

F4

PTFE

MS

Molybdenum disilicideMoSi

W

Other special materials

 

O

Ordinary waterproof type

D

flameproof typeExdIICT1T6

security level

 

100

250

400

600

900

1500

3000

Nominal lengthmm (No longer within the nominal length, can fill in the required length)

150

300

500

750

1000

2000

3500

200

350

550

800

1200

2500

Length requiredmm

WR

S

A

1

1

18

A

B

O

1200

Example of Selection

WRThermal resistance transmitter; platinum-rhodium10-Platinum thermocouple,PT10%RH-PtThe scope of application is01100Accuracy level, allowable deviation Δt(℃): Grade I ± (±)1.0)Level II ± (±)1.5); Equipped with a regular integrated transmission module and output two-wire system420mA DC; Single temperature sensing element; The pressure level is normal pressure or ≤0.2MpaHigh wear resistant type (single section type); The process connection isM27×2The material of the protective tube is304; Ordinary waterproof type; The nominal length is1200mm

◆ Parameters:Detachable, WR □□□□□ 08 □□□□, WZ □□□□ 08 □□□□ 、

◆ Model:WR、WZ-5

◆ Parameters:Fixed bolt type, WR □□□□□ 03 □□□□, WZ □□□□ 03 □□□□