UV Visible Intelligent Multi Parameter Water Quality TesterThe testing items are based on national industry standards, COD-《HJ/T399-2007》、 Ammonia nitrogen - "HJ 535-2009", total phosphorus - "GB11893-89", total nitrogen - "HJ 636-2012" The performance of the photometer meets the Level 2 requirements of the "JJG-178 Verification Regulations for Ultraviolet, Visible, and Near Infrared Spectrophotometers"
Features
1. Verification regulation: meets the Level 2 requirements of the JJG-178 Verification Regulation for Ultraviolet, Visible and Near Infrared Spectrophotometers;
2. Equipped with a multifunctional single colorimetric cell, compatible with 10mm, 20mm, 30mm colorimetric dishes and φ 16mm tube colorimetric. The upgraded limit function of the single colorimetric cell greatly improves the consistency and accuracy of sample measurement;
3. Easy maintenance: * Socket type tungsten/deuterium lamp, light replacement without optical debugging, equipment maintenance is simpler;
4. Specialized total nitrogen determination: can be used as a professional total nitrogen analyzer, with automatic switching between UV dual wavelengths, simple and easy to use, flexible and efficient, good wavelength repeatability, precise results, and direct concentration reading;
5. Preset curves: 67 measurement modes and 332 curves are preset, including 256 standard curves and 76 fitted curves;
6. Supporting reagents: well-equipped professional consumables and reagents, greatly reducing work steps and making measurements simpler and more accurate;
7. Accurate measurement: Using imported high-quality holographic gratings to further reduce instrument stray light, making instrument analysis more accurate;
8. Easy to operate: 7-inch color touch screen, user-friendly design, direct reading of concentration, Chinese display interface;
9. Data processing: It can store 12000 sets of data and can be freely viewed. It supports instant printing and can be uploaded to a computer;
10. Supporting digestion instrument: Equipped with a 30 hole dual temperature zone multi parameter digestion instrument, it can simultaneously digest water samples with two different temperature indicators, saving time.
3、 Technical parameters
1. Testing parameters
1. Instrument name:UV Visible Intelligent Multi Parameter Water Quality Tester
2. Instrument model: LH-3BA (V12)
3. Wavelength range: (190-1100) nm
4. Spectral bandwidth: 2.0nm
5. Wavelength repeatability: ≤± 0.2nm (190-340nm); ≤±0.5nm(340-1100nm)
6. Wavelength accuracy: ± 0.5nm (190-340nm); ±1.0nm(340-1100nm)
7. Stray light: ≤ 0.2% (220nm, 360nm); ≤0.5%(420nm)
8. Transmittance accuracy: ± 0.5%
9. Transmission density repeatability: ≤ 0.2%
10. Wavelength resolution: 0.1nm
11. Baseline straightness: ≤± 0.002A
12. Data storage: 12000 pieces of data
13. Instrument noise: ≤ 0.1% (transmittance 0%); ≤ 0.2% (transmittance of 99%)
2. Physical parameters
1. Display: 7-inch color touch screen
2. Printing: Thermal line printer
3. Data transmission: USB, infrared
4. Instrument weight: 25Kg
5. Dimensions: (524 × 445 × 238) mm
3. Environment and working parameters
1. Environmental temperature: (5-40) ℃
2. Environmental humidity: Relative humidity ≤ 85% RH (without condensation)
3. Rated voltage: AC220V ± 10%/50Hz
4. Rated power: 80W
4、 Measurement project
COD:
Analysis method: Rapid digestion spectrophotometry
According to the standard: HJ 399-2007
Range:
COD high range: pre made reagents: (20~15000) mg/L (segmented); Ordinary reagent: (20-10000) mg/L (segmented)
COD low range: pre made reagent: (2~150) mg/L; Ordinary reagent: (2~100) mg/L
Detection limit: COD high range 3mg/L; COD low range 0.5mg/L
Ammonia nitrogen 1:
Analysis method: Nessler's reagent spectrophotometric method
According to the standard: HJ 535-2009
Range: (0.05~80) mg/L (segmented)
Detection limit: 0.01mg/L
Ammonia nitrogen 2:
Analysis method: Salicylic acid spectrophotometric method
According to the standard: HJ 536-2009
Range: High Range: (0.5~50) mg/L; Low range: (0~2.5) mg/L
Detection limit: 0.001mg/L
Total phosphorus:
Analysis method: Ammonium molybdate spectrophotometric method
According to the standard: GB11894-89
Range: (0~7.5) mg/L (segmented)
Detection limit: 0.002mg/L
High range of total phosphorus:
Analysis method: Vanadium molybdenum yellow spectrophotometric method
According to the standard: GB/T21931.3-2008
Range: (2~100) mg/L
Detection limit: 0.5mg/L
Total nitrogen:
Analysis method: Alkaline potassium persulfate digestion UV spectrophotometry
According to the standard: HJ 636-2012
Range: (0~80) mg/L (segmented)
Detection limit: 0.1mg/L
Total nitrogen:
Analysis method: Color changing acid spectrophotometric method
Range: (0~100) mg/L (segmented)
Detection limit: 0.5mg/L
Turbidity:
Analysis method: Fumalazine spectrophotometric method
Range: (0.5~400) NTU
Detection limit: 0.5NTU
Chromaticity:
Analysis method: Platinum cobalt color system
Range: (0~2000) Hazen
Detection limit: 2Hazen
Suspended solids:
Analysis method: direct colorimetric method
Range: (0~1000) mg/L
Detection limit: 1mg/L
Permanganate index:
Analysis method: Oxidation spectrophotometry
Range: (0.3~20) mg/L
Detection limit: 0.5mg/L
Nitrate nitrogen:
Analysis method: Color changing acid spectrophotometric method
Range: (0~100) mg/L
Detection limit: 0.015mg/L
Nitrite nitrogen:
Analysis method: Naphthalene ethylenediamine hydrochloride spectrophotometric method
Range: (0~6) mg/L
Detection limit: 0.015mg/L
Free chlorine and total chlorine:
Analysis method: DPD spectrophotometric method
Range: (0~1.5) mg/L
Detection limit: 0.004mg/L
Phosphates:
Analysis method: Ammonium molybdate spectrophotometric method
Range: (0~25) mg/L
Detection limit: 0.005mg/L
Sulfate:
Analysis method: Barium chromate spectrophotometric method
Range: (3~1250) mg/L
Detection limit: 3mg/L
Fluoride:
Analysis method: Fluorine reagent spectrophotometric method
Range: (0~12) mg/L
Detection limit: 0.002mg/L
Sulfides:
Analysis method: spectrophotometric method
Range: (0~6) mg/L
Detection limit: 0.002mg/L
Cyanide Wu:
Analysis method: Iso barbituric acid spectrophotometric method
Range: (0~0.45) mg/L
Detection limit: 0.004mg/L
Iron:
Analysis method: Phenanthroline spectrophotometric method
Range: (0~50) mg/L
Detection limit: 0.004mg/L
Total chromium/hexavalent chromium:
Analysis method: Diphenylcarbazide spectrophotometric method
Range: (0~5) mg/L
Detection limit: 0.001mg/L
Zinc:
Analysis method: Zinc reagent spectrophotometric method
Range: (0~20) mg/L
Detection limit: 0.003mg/L
Copper:
Analysis method: BCA spectrophotometric method
Range: (0~50) mg/L
Detection limit: 0.01mg/L
Nickel:
Analysis method: Diketoxime spectrophotometric method
Range: (0~40) mg/L
Detection limit: 0.009mg/L
Lead:
Analysis method: Xylenol Orange spectrophotometric method
Range: (0~5) mg/L
Detection limit: 0.01mg/L
Cadmium:
Analysis method: Cadmium reagent spectrophotometric method
Range: (0~5) mg/L
Detection limit: 0.002mg/L
Manganese:
Analysis method: High oxidation spectrophotometry
Range: (0~50) mg/L
Detection limit: 0.038mg/L
Silver:
Analysis method: Cadmium reagent 2B spectrophotometric method
Range: (0~8) mg/L
Detection limit: 0.003mg/L
Antimony:
分析方法: 5-Br-PADAP 光度法
Range: (0~12) mg/L
Detection limit: 0.05mg/L
Aniline:
Analysis method: Naphthalene ethylenediamine hydrochloride spectrophotometric method
Range: (0~16) mg/L
Detection limit: 0.002mg/L
Nitrobenzene:
Analysis method: Naphthalene ethylenediamine hydrochloride spectrophotometric method
Range: (0~25) mg/L
Detection limit: 0.007mg/L
Volatile phenols:
Analysis method: 4-amino spectrophotometric method
Range: (0~25) mg/L
Detection limit: 0.005mg/L
Formaldehyde:
Analysis method: Acetylacetone spectrophotometric method
Range: (0~50) mg/L
Detection limit: 0.003mg/L
Trace arsenic:
Analysis method: New silver salt spectrophotometric method
Range: (0~0.012) mg/L
Detection limit: 0.001mg/L
Total arsenic:
Analysis method: Ag (DOC) spectrophotometric method
Range: (0~5) mg/L
Detection limit: 0.007mg/L
Mercury:
Analysis method: Dithizone photometric method
Range: (0~0.4) mg/L
Detection limit: 0.002mg/L
Anionic surfactants:
Analysis method: spectrophotometric method
Range: (0~2) mg/L
Detection limit: 0.01mg/L
Boron:
Analysis method: Curcumin photometric method
Range: (0~20) mg/L
Detection limit: 0.2mg/L
Iodide:
Analysis method: Catalytic colorimetric method
Range: ≥ 0.01mg/L
Detection limit: 0.001mg/L
Hydrazine hydrate:
Analysis method: p-methylaminobenzenal spectrophotometric method
Range: 0-10mg/L
Detection limit: 0.002mg/L
Carbon disulfide:
Analysis method: Diethylamine copper acetate spectrophotometric method
Range: 0-15mg/L
Detection limit: 0.015mg/L
Triethylamine:
Analysis method: Bromophenol blue spectrophotometric method
Range: 0-0.4mg/L
Detection limit: 0.002mg/L
Thiocyanate salt:
Analysis method: Isopyrazolone spectrophotometric method
Range: 0-15mg/L
Detection limit: 0.15mg/L
铍:
Analysis method: Chrome cyanine R spectrophotometric method
Range: 0-40mg/L
Detection limit: 0.01mg/L
Trichloroacetaldehyde:
Analysis method: Pyrazolinone spectrophotometric method
Range: 0-20mg/L
Detection limit: 0.08mg/L
Vanadium:
Analysis method: Tantalum reagent (BPHA) extraction spectrophotometry
Range: 0-100mg/L
Detection limit: 0.018mg/L
Barium:
Analysis method: Chromate indirect spectrophotometry
Range: 0-30mg/L
Detection limit: 0.06mg/L
Uranium:
Analysis method: TRPO-5-Br-PADAP photometric method
Range: 0-16mg/L
Detection limit: 0.002mg/L
Thorium:
Analysis method: Uranium reagent III photometric method
Range: 0-30mg/L
Detection limit: 0.008mg/L
Cobalt:
Analysis method: 5-Chloro-2- (Pyridylazo) -1,3-Diaminobenzene photometric method
Range: 0-1.6mg/L
Detection limit: 0.02mg/L