DeFelsko 6000 series coating thickness gauge
Instrument Features
Simple - Large and easy to read LCD display screen, menu can be displayed in Chinese
-Two key operation
-Instant automatic setting
-Automatic shutdown, integrated body can automatically turn on
-Average zeroing is beneficial for zeroing on rough surfaces
-The reset function can quickly restore the thickness gauge to its factory state
-There is a brief explanation on the back of the instrument
Durable and wear-resistant sapphire probe
-Acid resistant, oil resistant, water-resistant, solvent resistant, dust-proof
-The reading is not affected by vibration
-One year warranty period
Accurate - Each instrument comes with a calibration certificate that complies with NIST standards
-Can achieve an accuracy of *
-Can provide calibration procedures and standard plates
-Compliant with US and standards
Multifunctional - Metric and Imperial Unit Swap
-Multiple probes to choose from
-8 display languages, Chinese, English, French, German, Italian, Spanish, Portuguese, Japanese
DeFelsko 6000 series coating thickness gauge separation probe:
-Interchangeable probes, instant automatic recognition
-High quality flexible anti damage connection
-Extended connection (up to 75m) for remote measurement
-Durable gold-plated lockable connectors suitable for industrial environments
-All standard probes can be used underwater
-All standard constant pressure probes are finely ground to ensure high precision
-All constant pressure probes are positioned with V-shaped grooves and chamfers for easy measurement of the inside and outside of the pipe
-*The miniature probe can be used for small and difficult to reach surfaces, with three configurations: 0 °, 45 °, and 90 °
Dual purpose thickness gauge (FN type) for PosiTector 6000 series coating thickness gauge:
All metal surfaces can be measured without the need to replace the probe
Automatic recognition of iron/non-ferrous metal surfaces
Reduce the impact of misoperation
Measurable metal surface electroplating layer, oxide film, coating, chrome plating layer, etc
*The 'N-LOCD' function can measure coatings on slightly magnetic substrates
Provide integrated and separated probe configurations
The ideal choice for measuring powder coatings
The separated probe is convenient for measuring inside, outside, and difficult to reach surfaces of the tube
Various probes can be applied to a wide range of applications
DeFelsko 6000 series coating thickness gauge has multiple functions:
F-type probe is used for non-magnetic coating on steel, such as paint, plastic, enamel, chromium, zinc, etc
N-type probes are used for all insulation layers on non-ferrous metals (such as copper, aluminum, austenitic stainless steel), such as anodized films, paints, coatings, etc
The FN probe is a dual-use probe developed to automatically switch measurements on magnetic and non-magnetic substrates
DeFelsko 6000 series coating thickness gaugeOptional models

Note:
| 1- Standard type | Can store 250 readings; When the reading exceeds the set range, there will be sound and light prompts; Display the average value, standard deviation, maximum/minimum thickness value, and measurement frequency; Built in infrared transmission port USB interface, can connect to a computer, browse data, no software required |
| 3- Advanced type | newly added: |
| F-type probe | Non magnetic coatings used on magnetic substrates such as steel, such as paint, plastic, enamel, chromium, zinc, etc |
| N-type probe | Used for all insulation layers on non-ferrous metals (such as copper, aluminum, austenitic stainless steel), such as anodized film, paint, etc |
| FN type probe | As a dual-purpose probe, it can automatically switch measurements on magnetic and non-magnetic substrates |
| Wireless infrared printer | Optional accessories, statistical and storage type can transmit data to infrared printers without installing connectors or connections |
Note:
The standard model can store 250 readings;
When the reading exceeds the set range, there will be sound and light prompts;
Display the average value, standard deviation, maximum/minimum thickness value, and measurement frequency;
Built in infrared transmission port
USB interface, can connect to a computer, browse data, no software required
3- Advanced type
newly added:
Store 10000 readings, which can be divided into 1000 groups
Built in clock
Can store calibration
SSPC PA-2 function, calculate the average value of a set of average readings
F-type probe is used for non-magnetic coating on magnetic substrates such as steel, such as paint, plastic, enamel, chromium, zinc, etc
N-type probe is used for all insulation layers on non-ferrous metals (such as copper, aluminum, austenitic stainless steel), such as anodized film, paint, etc
The FN probe is a dual-purpose probe that can automatically switch measurements on magnetic and non-magnetic substrates
Wireless infrared printer optional accessories, statistical and storage type can transmit data to the infrared printer without installing connectors or connections