Taiwan, China Shangtai Portable Residual Chlorine Tester Shangtai Instrument Co., Ltd

NegotiableUpdate on 01/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Product Introduction Shangtai Portable Residual Chlorine Detector, Taiwan, China, China Shangtai Instrument Co., Ltd. I-2001/K-2513 Application: widely used in swimming pool chlorination control, pure water, drinking water quality, hospital wastewater discharge monitoring, circulating water automatic dosing, monitoring and other application fields.

Product Details

Taiwan, China Shangtai Portable Residual Chlorine Tester Shangtai Instrument Co., Ltd. I-2001/K-2513

feature
I-2001 has waterproof function
Measurement concentration: 515nm
Preset calibration curve (US EPA standard)
Press the button to automatically confirm the zeroing function
Test range: 0.01~6.00mg/L
Paired with reagents, it can measure two parameters: residual chlorine and total chlorine
Thin film buttons, easy to operate, stable reading in seconds
Equipped with automatic shutdown function

Shangtai Instrument Co., Ltd. I-2001/K-2513

Application: Widely used in swimming pool chlorine control, pure water, drinking water quality, hospital wastewater discharge monitoring, circulating water self-control dosing, monitoring and other application fields.
Measurement principle: This CLE residual chlorine sensor is an ammeter type sensor with two electrodes coated with a thin film. It is basically composed of a thin film and electrode rods. The membrane cap is filled with electrolyte to form a detection chamber. The thin film of the membrane cap is covered with micropores, allowing gases in the sampled water to enter the detection chamber. The electrode on the electrode rod is inserted into the detection chamber. An amplifying electronic circuit is installed on the electrode inside the electrode rod. There are electrical connections on electronic circuits. The temperature compensated detector is assembled as a whole at the lower end of the electrode rod.
Shangtai Instrument Co., Ltd. I-2001/K-2513

Specification: Measurement range: 0.01-20mg/L (ppm) HOCL

Small detection limit: 0.1mg/L (ppm) HOCL

PH range: 5.5-8.0

Temperature range: 5-45 ℃

Temperature fluctuation rate: 0.3 ℃/min

Pressure: 1 bar (do not use negative pressure)